Specifications
Frequency Output Load Resistance Value
|
|
|
| Rmax = (Vsupply - 4)/0.003 |
|
|
|
| |||||
|
|
|
| *Rmin = (Vsupply - 25)/0.006 |
|
|
|
| |||||
| *Absolute minimum = 100 Ohms for Vsupply < 25.6 volts |
| |||||||||||
| 10000 |
|
|
|
|
|
|
|
|
|
|
|
|
| 9000 |
|
|
|
|
|
|
|
|
|
|
|
|
(Ohms) | 8000 |
|
|
|
|
|
|
|
|
|
|
|
|
7000 |
|
|
|
|
|
|
|
|
|
|
|
| |
6000 |
|
|
|
|
|
|
|
|
|
|
|
| |
resistor |
|
|
|
|
|
|
|
|
|
|
|
| |
5000 |
|
|
|
|
|
|
|
|
|
|
|
| |
4000 |
|
|
|
|
|
|
|
|
|
|
|
| |
External | 3000 |
|
|
|
|
|
| Operating |
|
|
| ||
2000 |
|
|
|
|
|
| Region |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 1000 |
|
|
|
|
|
|
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
| 5 | 7 | 9 | 11 | 13 | 15 | 17 | 19 | 21 | 23 | 25 | 27 | 29 |
Supply voltage (volts)
•Discrete output (Model 2700 only):
-Can report event 1, event 2, event 1 or 2, flow direction, flow switch, calibration in progress, or fault
-Configurable polarity: active high or active low
Model 2700 transmitters with
One or two
•Channel A is always an mA output; Channel B is configurable as an mA output
•Not intrinsically safe
•Internally powered (active)
•Isolated to ±50 VDC from all other outputs and earth ground
•Maximum load limit:
-Channel A (mA1): 820 Ohms
-Channel B (mA2): 420 Ohms
•Can report mass flow, volume flow, density, temperature, or drive gain; transmitters with the petroleum measurement application (API) or enhanced density application can also report standard volume flow and density at reference temperature
•Linear with process from 3.8 to 20.5 mA, per NAMUR NE43 (June 1994)
Output Wiring – Intrinsically Safe
Output Wiring – Configurable I/O Output Wiring – Fieldbus/PROFIBUS
Specifications
Installation Manual | 59 |