FULL SIZE GAS CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
2.Independent doors:
A.Remove the door handle then remove the outer door panel.
B.Lift out the inner door panel and window assembly.
NOTE: Left door only - remove door seal from the inside edge of the door.
3. Simultaneous doors:
5.Reverse procedure to install the replacement window.
A. If replacing window on the left door, remove the handle from the front of the door then remove door seal from the inside edge of the door.
1)Lift out the inner door panel and window assembly.
2)If replacing window on the right door, remove the screws along the inside edge (if applicable) of the door then remove the inner door panel and window assembly.
4.Remove the screws securing the window TABS to the door bracket and lift the window assembly out from the door frame.
DOOR SWITCH
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1.Remove the top front cover as outlined under
COVERS AND PANELS.
2.Disconnect the lead wires to the door switch.
3.Remove the switch.
4.Reverse procedure to install the replacement switch and check for proper adjustment as outlined under DOOR SWITCH ADJUSTMENT in
SERVICE PROCEDURES AND ADJUSTMENTS.
Page 15 of 64 |
| F32700 (February 2006) |
|