FULL SIZE GAS CONVECTION OVENS - CONDENSED SPARE PARTS LIST
CODE & PROBLEM | PROBABLE CAUSE | SOLUTION |
|
Er06 - Zone 1 A/D underflow | • Incorrect sensor type | • Check the InP1 setup parameter. | |
error | • Measuring temperature outside the | Verify it matches your sensor. |
|
| sensor range | • Check sensor and connections | for a |
|
| reversed or open sensor. If the |
|
|
| condition causing the error is |
|
|
| resolved, the error will clear. |
|
Er07 - Zone 1 A/D overflow | Open sensor | • Check the InP1 setup parameter. | |
error |
| Verify it matches your sensor. |
|
|
| • Check sensor and connections | for a |
|
| reversed or open sensor. If the |
|
|
| condition causing the error is |
|
|
| resolved, the error will clear. |
|
Er10 - Stack overflow error | Microprocessor malfunction | • Cycle power. |
|
|
| • Check sensor and connections | for a |
|
| reversed or open sensor. |
|
Er11 - Open sensor error | Open sensor | • Check the InP1 setup parameter. | |
|
| Verify it matches your sensor. |
|
|
| • Check sensor and connections | for a |
|
| reversed or open sensor. |
|
Er12 - Shorted sensor | • Incorrect sensor type | • Check the InP1 setup parameter. | |
| • Measuring temperature outside the | Verify it matches your sensor. |
|
| sensor range | • Check sensor and connections | for a |
|
| reversed or open sensor. |
|
CONDENSED SPARE PARTS LIST
WKG SERIES
Part No. | Description |
|
|
Main Power Switch (On/Off/Oven Cool) | |
|
|
Thermostat, KX (WKG, WKGX) | |
|
|
Temperature Control Board (WKGD, WKGDX) | |
|
|
Temperature Probe (WKGD, WKGDX) | |
|
|
Door Switch | |
|
|
Gas Valve, Natural | |
|
|
Gas Valve, Propane | |
|
|
Ignition Module | |
|
|
Heat Relay | |
|
|
High Limit Thermostat | |
|
|
Igniter/Flame Sensor | |
|
|
Timer - 60 Minute | |
|
|
Light Switch, Roast & Hold or Fan Speed | |
|
|
Blower Motor, 2Sp. 120 Volt | |
|
|
Computer Control (WKGC, WKGCX) | |
|
|
Temperature Probe (WKGC, WKGCX) | |
|
|
SST Relay (WKGD, WKGDX) | |
|
|
Transformer |
F32700 (February 2006) | Printed in U.S.A. |