Wolf WKGCX 126625, WKGDX 126624, WKGX 126623, WKGC 126622 GAS Orifice, GAS Solenoid Valve

Page 9

FULL SIZE GAS CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS

6.Reverse procedure to install the replacement burner.

NOTE: Ensure that burner positioning bracket (U shaped end) is inserted into slot at the rear of the burner chamber.

7. Check for proper operation.

GAS ORIFICE

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

WARNING: SHUT OFF THE GAS BEFORE SERVICING THE UNIT.

1.Remove the bottom front cover as outlined under

COVERS AND PANELS.

2.Remove the bolts securing the gas manifold to the oven and place the manifold to the side.

4.Reverse procedure to install and check for proper operation.

GAS SOLENOID VALVE

WARNING: DISCONNECT THE

ELECTRICAL POWER TO THE

MACHINE AND FOLLOW LOCKOUT /

TAGOUT PROCEDURES.

WARNING: SHUT OFF THE GAS BEFORE SERVICING THE UNIT.

WARNING: ALL GAS JOINTS DISTURBED DURING SERVICING MUST BE CHECKED FOR LEAKS. CHECK WITH A SOAP AND WATER SOLUTION (BUBBLES). DO NOT USE AN OPEN FLAME.

1.Remove the control panel and the right side panel as outlined under COVERS AND PANELS.

NOTE: If right side panel is not accessible, this component can be serviced by removing the control panel as outlined under COVERS AND PANELS.

2.Disconnect the lead wires.

3.Disconnect the compression fittings to the valve.

3.Remove the gas orifice from the spud on the manifold and replace with the correct orifice for the given altitude.

Page 9 of 64

 

F32700 (February 2006)

 

Image 9
Contents WKG Series Full Size GAS Convection Ovens Table of Contents Computer Control Models Only Specifications Installation Operation Cleaning LubricationIntroduction ToolsTop Front Cover Covers and PanelsBottom Front Cover Control PanelControl Panel Components Removable Components ProcedureComponent Panel Components GAS Burner Temperature Probe WKGD/WKGDXGAS Solenoid Valve GAS OrificeSpark Igniter Flame Sense Ignition Control ModuleBlower and Motor Oven Doors and Bearings Independent Doors Oven Doors Simultaneous Doors Assembly RemovalDoor Catch Ball Assembly Independent Doors DisassemblyDoor Window Door Switch High Limit Thermostat Interior LightsLamp Cooling FAN Lamp AssemblySolid State Temperature Control Calibration WKGD/WKGDX Service Procedures and AdjustmentsMechanical Thermostat Calibration WKG/WKGX Solid State TemperatureTemperature Probe Test WKGD/WKGDX Temperature Probe Test WKGD/WKGDXTemp F Ohms GAS Pressure AdjustmentVerification of Spark AT Ignitor Door Switch AdjustmentBlower Adjustment Door Catch Ball Adjustment Independent Doors Door AdjustmentIntroduction ProcedureComputer Control WKGC/WKGCX Operation Setup ModeComputer Control Calibration WKGC/WKGCX Probe TestSolid State Relay Test Function Switch S3 Door SwitchComponent Function Blower Motor Solid State Temperature ControlMotor Speed Relay R1 Computer ControlMechanical Temperature Control Temperature ProbeComponent Location Gas Valve Dual SolenoidWKG/WKGX Plug, Socket and Components Standard Controls WKGD/WKGDX Plug, Socket and Components Standard Controls Full Size GAS Convection Ovens Electrical Operation WKGC/WKGCX Plug, Socket and Components Roast & Hold Standard Sequence of Operation WKG, Wkgx With Roast & Hold Option Mechanical KX ThermostatNormal Roast Cycle Roast and Hold Cycle Timer Cycle Normal Roast CookingFull Size GAS Convection Ovens Electrical Operation Timer Cycle Roast & Hold Cooking WKGD, Wkgdx With Roast & Hold Option Solid State Temperature ControlTimer Cycle Normal Roast Cooking Roast and Hold Cycle Timer Cycle Roast & Hold Cooking Oven Cool Cycle Solid State Temperature Control Roast Cycle Normal Cooking Roast & Hold Standard on Computer ModelFull Size GAS Convection Ovens Electrical Operation Oven Cool Cycle Computer Control Model Temperature and Time Cycle CookingWKG, Wkgx Mechanical KX Controls SchematicsWKG, Wkgx Mechanical KX Controls, Roast & Hold Option WKGD, Wkgdx Solid State Temperature Control Full Size GAS Convection Ovens Electrical Operation WKGC, Wkgcx Computer Control Roast & Hold Standard Wiring Diagrams Full Size GAS Convection Ovens Electrical Operation WKG, Wkgx Mechanical KX Controls, Roast & Hold Option Full Size GAS Convection Ovens Electrical Operation WKGD, Wkgdx Solid State Temperature Control Full Size GAS Convection Ovens Electrical Operation Full Size GAS Convection Ovens Electrical Operation Full Size GAS Convection Ovens Electrical Operation WKGC, Wkgcx Computer Control Roast & Hold Standard Full Size GAS Convection Ovens Electrical Operation ALL Models TroubleshootingComputer Control Models only Error CodesDescription Condensed Spare Parts List