KitchenAid 30, 36, 48 installation instructions Venting methods, Calculating the vent system length

Page 4

Venting methods

This canopy range hood is factory set for venting through the roof or wall. For non- vented (recirculating) installations, see “Non-Vented (Recirculating) Kits” on back page.

Vent system needed for installation is not included. 3-1/4" x 10" (8.3 cm x 25 cm) rectangular, 7" (17.8 cm) round, 8"

(20.3 cm) round or 9" (22.9 cm) round vent may be used. The hood exhaust opening is 3-1/4" x 10" (8.3 cm x 25 cm).

Vent system can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.

The vent system length should not exceed the lengths shown in the chart below.

Vent size

Maximum length

3-1/4" x 10"

35 ft. (10.7 m)

(8.3 cm x 25 cm)

 

7" (17.8 cm) round

40 ft. (12.2 m)

 

 

8" (20.3 cm) round

50 ft. (15.2 m)

 

 

9" (22.9 cm) round

60 ft. (18.3 m)

 

 

Vertical roof venting

roof cap

3-1/4" x 10"

(8.3 cm x 25 cm) through the roof

Note: 3-1/4" x 10" (8.3 cm x 25 cm) rectangular vent must be used inside chimney cover. Round vent will not fit inside chimney cover.

Horizontal wall venting

3-1/4" x 10"

(8.3 cm x 25 cm) through the wall

wall cap

Calculating the vent system length

To calculate the length of the system you need, add the equivalent feet for each vent piece used in the system.

Vent Piece

3-1/4" x 10" (8.3 cm x 25 cm)

7" (17.8 cm), 8" (20.3 cm)

 

Rectangular

or 9" (22.9 cm) Round

45° elbow

7.0 feet

2.5 feet

 

(2.1 m)

(0.8 cm)

90° elbow

5.0 feet

5.0 feet

 

(1.5 m)

(1.5 m)

90° flat elbow

12.0 feet

 

 

(3.7 m)

 

transition to round

5.0 feet

 

 

(1.5 m)

 

wall cap

0.0 feet

 

 

(0.0 m)

 

3-1/4" x 10" (8.3 cm x 25 cm)

vent system

3-1/4" x 10”

 

 

 

wall

(8.3 cm x 25 cm)

 

 

 

 

 

 

cap

elbow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 ft. (1.8 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2ft.

(0.6 m)

Maximum length

= 35 ft. (10.7 m)

1 — 90° elbow

=

5 ft.

(1.5 m)

8 ft. (2.4 m) straight

=

8 ft.

(2.4 m)

1 — wall cap

=

0 ft.

(0 m)

Length of 3-1/4" x 10"

 

 

 

 

 

 

(8.3 cm x 25 cm)

 

 

 

system

= 13 ft.

(4 m)

Note: Flexible vent is Not recommended.

If it is used, each foot of flexible vent used is equivalent to two feet

(61 cm) of straight metal vent when calculating the vent system length. (Example: A flexible elbow equals two standard elbows.)

4

Image 4
Contents Installation Instructions Use and Care Guide Parts needed Tools neededParts supplied Venting requirements Product dimensions Cabinet dimensionsFor the most efficient and quiet operation Venting methods Calculating the vent system lengthElectrical requirements Installation stepsPreparation Electrical connection Check operation Use and Care Information CleaningOperation Wiring diagram AccessoriesMaintenance If you need serviceKitchenAid will PAY for WarrantyKitchenAid will not PAY for Requesting Assistance or Service Our consultants provide assistance withExcept 807 area code Direct service branches807 area code in Ontario Instructions d’installation et Pour consultation ultérieurePièces nécessaires Pièces fourniesDimensions du produit Dimensions des placards Circuit de décharge de l’airConfigurations de circuit de décharge Calcul de la longueur effective du système de déchargeLes étapes de l’installation Alimentation électriquePréparation Quincy, Massachusetts CSA InternationalBride Supérieuresection supérieure de la cheminée Bride ConduitCheminée Section inférieure Cheminée Sectionvis Supérieure VisEmplacement des Organes de commande Mettre le système sous tensionContrôler le fonctionnement de la hotte ’éclairageLe ventilateur est commandé par un variateur de vitesse Renseignements d’utilisation et entretienUtilisation de la hotte NettoyageAccessoires EntretienSchéma de câblage Si une assistance est nécessaireKitchenAid Paiera GarantieKitchenAid NE Paiera PAS Demande dassistance ou de service Si vous avez besoin dassistance ou de service aux É.-USi vous avez besoin de pièces de rechange Pour plus dassistanceDemande d’assistance ou de service Si vous avez besoin dassistance ou de service au CanadaPour plus d’assistance 30 et 18 h 00 HNE, en composant