KitchenAid W10137649AS Product Data Sheets, Application Guidelines/Water Supply Parameters

Page 18

PRODUCT DATA SHEETS

Interior Water Filtration System

Model 67003523-750 Capacity 750 Gallons (2839 Liters)

System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead, Mercury, Atrazine, Toxaphene, Cysts, Turbidity, Asbestos and Lindane.

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Substance Reduction

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum%

Average%

Aesthetic Effects

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Chlorine Taste/Odor

50% reduction

1.88 mg/L

2.0 mg/L ± 10%

0.06 mg/L

0.05 mg/L

96.84

>97.26

Particulate Class I*

85% reduction

5,700,000 #/mL

At least 10,000

69,000 #/mL**

30,583 #/mL

98.94

99.52

 

 

 

particles/mL

 

 

 

 

 

 

 

 

 

 

 

 

Contaminant

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum%

Average%

Reduction

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Lead: @ pH 6.5

0.010 mg/L

0.153 mg/L

0.15 mg/L ± 10%

< 0.001mg/L

< 0.001mg/L

>99.29%

>99.35%

Lead: @ pH 8.5

0.010 mg/L

0.150 mg/L

0.15 mg/L ± 10%

< 0.001mg/L

< 0.001mg/L

>99.29%

>99.33%

 

 

 

 

 

 

 

 

Mercury: @ pH 6.5

0.002 mg/L

0.006 mg/L

0.006 mg/L ± 10%

0.0005 mg/L

0.0003 mg/L

90.91

95.70

Mercury: @ pH 8.5

0.002 mg/L

0.006 mg/L

0.006 mg/L ± 10%

0.0015 mg/L

0.0008 mg/L

75.93

86.22

 

 

 

 

 

 

 

 

Toxaphene

0.003 mg/L

0.015 mg/L

0.015 ± 10%

< 0.001mg/L

< 0.001mg/L

91.67%

92.97%

 

 

 

 

 

 

 

 

Atrazine

0.003 mg/L

0.009mg/L

0.009 mg/L ± 10%

< 0.002 mg/L

< 0.002 mg/L

75.31%

76.99%

 

 

 

 

 

 

 

 

Asbestos

99%

155 MF/L

107 to 108 fibers/L††

< 1 MF/L

< 1 MF/L

>99.99%

>99.99%

 

 

 

 

 

 

 

 

Live Cysts

>99.95%

166,500 #/L

50,000/L min.

< 1 #/L

< 1 #/L

>99.99

>99.99

Turbidity

0.5 NTU

10.7 NTU

11 ± 1 NTU

0.49 NTU

0.31 NTU

95.2

97.09

 

 

 

 

 

 

 

 

Lindane

0.0002 mg/L

0.002 mg/L

0.002 ± 10%

< 0.0001mg/L

0.000 mg/L

96.50%

98.72%

 

 

 

 

 

 

 

 

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).

It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter’s rated life is used, the yellow (Order) light comes on. When 100% of the filter’s rated life is used, the red (Replace) light comes on, and it is recommended that you replace the filter. Use replacement filter model 67003523; order Part Number 4396395. 2007 suggested retail price of $49.99 U.S.A./$65.95 Canada. Prices are subject to change without notice.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Refer to the “Water Filtration System” section for the Manufacturer’s name and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

35 - 120 psi (241 - 827 kPa)

Water Temperature

33° - 100°F (1° - 38°C)

Service Flow Rate

0.78 gpm (2.9 L/min.) @ 60 psi.

*Class I particle size: >0.5 to <1 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. ††Fibers greater than 10 um in length

Based on the use of Cryptosporidium parvum oocysts ® NSF is a registered trademark of NSF International.

18

Image 18
Contents Refrigerator Safety Refrigerator User InstructionsUnpack the Refrigerator Installation InstructionsClean Before Using Remove the PackagingLocation Requirements Electrical RequirementsWater Supply Requirements Connect to Refrigerator Connect the Water SupplyConnect to Water Line StyleRefrigerator Door and Drawer Freezer Drawer Reverse Door Panel SeriesReplace Door and Hinges Remove Drawer FrontArchitect Series Top HingeBottom Hinge Panel Series Remove the Door Panel Adjust the DoorFactory Trim Kit Replace the Door PanelUsing the Controls Refrigerator USEElectronic Controls Digital ControlsCrisper Humidity Control Ice Maker Water Filtration SystemWater Dispenser Cleaning Refrigerator CareChanging the Light Bulb Troubleshooting Refrigerator OperationTemperature and Moisture Ice and WaterWater Filter Certifications Water is leaking from the dispenser systemWater from the dispenser is warm Product Data Sheets Application Guidelines/Water Supply ParametersItems Kitchenaid will not PAY for Kitchenaid Refrigerator WarrantyONE Year Limited Warranty Disclaimer of Implied Warranties Limitation of RemediesInstructions Dutilisation DU Réfrigérateur Sécurité DU RéfrigérateurAvant de jeter votre vieux réfrigérateur ou congélateur Instructions D’INSTALLATIONDéballage du réfrigérateur Enlèvement des matériaux d’emballageSpécifications électriques Exigences demplacementMéthode recommandée de mise à la terre Spécifications de l’alimentation en eauAlimentation en eau par osmose inverse Raccordement de la canalisation deauPression de leau Raccordement à une canalisation d’eauAchever l’installation Plastique Tube de cuivre Orifice darrivée deau Bride en PPorte et tiroir du réfrigérateur Réinstallation de la façade du tiroir Remplacement de la porte et des charnièresRetirer et réinstaller le tiroir du congélateur Enlèvement de la façade du tiroirCharnière supérieure Série ArchitectSérie avec panneaux décoratifs Garniture de poignéeStyle 1-Nivellement avant et arrière Ajustement de la porteEnsemble décoratif de l’usine Style 2- Vis pied de réglage de laplombDimensions pour lusinage du panneau de porte Panneaux unis Réinstallation du panneau de porteInstallation des panneaux personnalisés en bois Dimensions pour les panneaux en bois personnalisésCommandes numériques Utilisation des commandesCommandes électroniques Utilisation DU RéfrigérateurPour ajuster les réglages de température Holiday Mode mode vacancesTemp Alarm alarme de dépassement de température Caractéristique OptimIceRéglage de lhumidité dans le bac à légumes Machine à glaçonsSystème de filtration de leau Remplacement du filtre à eauDistributeur d’eau Distribution d’eauRemplacement de l’ampoule d’éclairage Entretien DU RéfrigérateurNettoyage Dépannage Fonctionnement du réfrigérateurLes portes sont difficiles à ouvrir Température et humiditéGlaçons et eau La température est trop élevéeLe distributeur deau ne fonctionne pas correctement Les glaçons sont creux ou petitsGoût, odeur ou couleur grise des glaçons ’eau coule du système de distributionFeuilles DE Données SUR LE Produit Système de filtration d’eau intérieurKitchenaid NE Prendra PAS EN Charge Garantie DU Réfrigérateur KitchenaidGarantie Limitée DE UN AN W10137649A SP PN W1013750A