GE GFE28HSHSS, GFE28HGHBB, GFE28HMHES Performance Data Sheet Model GE RPWFE, Rpwfe

Models: GFE28HSHSS GFE28HMHES GFE28HGHBB

1 136
Download 136 pages 45.14 Kb
Page 44
Image 44
Performance Data Sheet

Performance Data Sheet

Model: GE RPWFE

Use Replacement Cartridge RPWFE.

The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International against NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below.

Capacity 170 Gallons (643.5 Liters). Contaminant Reduction Determined by NSF testing.

 

 

 

 

Average Product

Max Permissible

 

 

Substance Tested

 

NSF specified

Avg %

Water

Product Water

NSF Reduction

NSF

for Reduction

Average Influent

Challenge Concentration

Reduction

Concentration

Concentration

Requirements

Test Report

Chlorine Taste and Odor

2.0 mg/L

2.0 mg/L ± 10%

97.4%

0.05 mg/L

N/A

≥50%

J-00102044

Nominal Particulate

 

 

 

 

 

 

 

Class I, , ≥0.5 to < 1.0 μm

7,633,333 pts/mL

At least 10,000 particles/mL

99.0%

71,850 pts/ml

N/A

≥85%

J-00106249

 

 

107 to 108 fibers/L; fibers

 

 

 

 

 

Asbestos

109 MFL

greater than 10μm in length

99.99%

<1 MFL

N/A

≥99%

J-00102069

Atrazine

0.009 mg/L

0.009 mg/L ± 10%

94.4%

0.0005 mg/L

0.003 mg/L

N/A

J-00102058

Benzene

0.016 mg/L

0.015 mg/L ± 10%

96.4%

0.001 mg/L

0.005 mg/L

N/A

J-00102065

Carbofuran

0.08 mg/L

0.08 mg/L ± 10%

98.8%

0.001 mg/L

0.04 mg/L

N/A

J-00102059

Cyst*

104,750 cysts/L

Minimum 50,000 cysts/L

99.99%

3 cyst/L

N/A

≥99.95%

J-00102057

Lead pH @6.5

0.140 mg/L

0.15 mg/L ± 10%

99.3%

0.001 mg/L

0.010 mg/L

N/A

J-00102052

Lead pH @8.5

0.158 mg/L

0.15 mg/L ± 10%

98.3%

0.002 mg/L

0.010 mg/L

N/A

J-00102053

Mercury @ pH 6.5

0.006 mg/L

0.006 mg/L ± 10%

91%

0.0003 mg/L

0.002 mg/L

N/A

J-00102054

Mercury @ pH 8.5

0.006 mg/L

0.006 mg/L ± 10%

88.3%%

0.0007 mg/L

0.002 mg/L

N/A

J-00104087

Lindane

0.002 mg/L

0.002 mg/L ± 10%

99%

0.00002 mg/L

0.0002 mg/L

N/A

J-00102063

P-Dichlorobenzene

0.222 mg/L

0.225 mg/L ± 10%

99.8%

0.0005 mg/L

0.075 mg/L

N/A

J-00102067

Toxaphene

0.015 mg/L

0.015 mg/L ± 10%

93.5%

0.001 mg/L

0.003 mg/L

N/A

J-00102061

2, 4-D Reduction

0.218 mg/L

0.210 mg/L±10%

99.9%

0.0001 mg/L

0.07 mg/L

N/A

J-00102064

VOC

0.278 mg/L

0.300 mg/L ± 10%

97.7%

0.0015 mg/L

N/A

≥95%

J-00102070

*Based on the use of Cryptosporidium parvum oocysts.

The following pharmaceutical reduction claims have not been certified by NSF International. Claims tested and verified by independent laboratory:

 

 

 

 

 

Max Permissible

 

Substance

 

NSF specified

Avg %

Average Product Water

Product Water

NSF

Reduction

Average Influent

Challenge Concentration

Reduction

Concentration

Concentration

Test Report

Atenolol

1088 ng/L

N/A

99.5%

5.0 ng/L

N/A

J-00103221

Fluoxetine

845 ng/L

N/A

99.4%

5.0 ng/L

N/A

J-00103221

Ibuprofen

898 ng/L

N/A

98.8%

9.9 ng/L

N/A

J-00103726

Progesterone

945 ng/L

N/A

99.4%

5.5 ng/L

N/A

J-00103727

Trimethoprim

403 ng/L

N/A

99.5%

2.0 ng/L

N/A

J-00103221

Application Guidelines/Water Supply Parameters

Service Flow

0.5 gpm (1.89 lpm)

Water Supply

Potable Water

Water Pressure

25-120 psi (172– 827 kPa)

Water Temperature

33º F - 100º F (0.6º C - 38º C)

It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised. See Installation Manual for Warranty information.

Note: While the testing was performed under standard laboratory conditions, actual performance may vary.

Replacement Cartridge: RPWFE. For estimated costs of replacement elements please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.

Application Guidelines/Water Supply ParametersWARNING

To reduce the risk associated with ingestion of contaminants:

~Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before and after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. EPA Establishment Number 070595-MEX-001.

NOTICE

To reduce the risk of water leakage or flooding, and to ensure optimal filter performance:

~Read and follow use instructions before installation and use of this system. ~8]bcP[[PcX^]P]SdbTMUST comply with all state and local plumbing codes.

~Do not install if water pressure exceeds 120 psi (827 kPa). If your water pressure exceeds 80 psi, you must install a pressure-limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.

~Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.

~Do not install on hot water supply lines. The maximum operating water temperature of this filter system is 100º F (38º C).

~Protect filter from freezing. Drain filter when temperatures drop below 33ºF (0.6ºC).

~2WP]VTcWTSXb_^bPQ[T [cTaRPacaXSVTTeTahbXg\^]cWb^ab^^]TaXUh^d^QbTaeT a noticeable reduction in water flow rate.

~5PX[daTc^aT_[PRTcWTSXb_^bPQ[T [cTaRPacaXSVTPcaTR^\\T]STSX]cTaeP[b\Ph lead to reduced filter performance and cracks in the filter housing, causing water leakage or flooding.

REPLACEMENT

ELEMENT

Tested and certified by NSF International against NSF/ANSI Standard 42 and Standard 53 in model GE RPWF and GE RPWFE for the reduction of the claims specified on the performance data sheet.

RPWFE

44

Page 44
Image 44
GE GFE28HSHSS, GFE28HGHBB Performance Data Sheet Model GE RPWFE, Rpwfe, Application Guidelines/Water Supply Parameters