KitchenAid KBFA25ERSS01 manual Product Data Sheets, Application Guidelines/Water Supply Parameters

Page 22

PRODUCT DATA SHEETS

Interior Water Filtration System

Model 67003523-750 Capacity 750 Gallons (2839 Liters)

Tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor, Particulate Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead, Mercury, Atrazine, Toxaphene, Cysts, Turbidity, Asbestos and Lindane.

This system has been tested according to NSF/ANSI 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.

Substance Reduction

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum%

Average%

Aesthetic Effects

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Chlorine Taste/Odor

50% reduction

1.88 mg/L

2.0 mg/L ± 10%

0.06 mg/L

0.05 mg/L

96.84

>97.26

Particulate Class I*

85% reduction

5,700,000 #/mL

At least 10,000

69,000 #/mL**

30,583 #/mL

98.94

99.52

 

 

 

particles/mL

 

 

 

 

 

 

 

 

 

 

 

 

Contaminant

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum%

Average%

Reduction

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Lead: @ pH 6.5

0.010 mg/L

0.153 mg/L

0.15 mg/L ± 10%

< 0.001mg/L

< 0.001mg/L

>99.29%

>99.35%

Lead: @ pH 8.5

0.010 mg/L

0.150 mg/L

0.15 mg/L ± 10%

< 0.001mg/L

< 0.001mg/L

>99.29%

>99.33%

 

 

 

 

 

 

 

 

Mercury: @ pH 6.5

0.002 mg/L

0.006 mg/L

0.006 mg/L ± 10%

0.0005 mg/L

0.0003 mg/L

90.91

95.70

Mercury: @ pH 8.5

0.002 mg/L

0.006 mg/L

0.006 mg/L ± 10%

0.0015 mg/L

0.0008 mg/L

75.93

86.22

 

 

 

 

 

 

 

 

Toxaphene

0.003 mg/L

0.015 mg/L

0.015 ± 10%

< 0.001mg/L

< 0.001mg/L

91.67%

92.97%

 

 

 

 

 

 

 

 

Atrazine

0.003 mg/L

0.009mg/L

0.009 mg/L ± 10%

< 0.002 mg/L

< 0.002 mg/L

75.31%

76.99%

 

 

 

 

 

 

 

 

Asbestos

99%

155 MF/L

107 to 108 fibers/L††

<1 MF/L

<1 MF/L

>99.99%

>99.99%

 

 

 

 

 

 

 

 

Live Cysts

>99.95%

166,500 #/L

50,000/L min.

<1 #/L

<1 #/L

>99.99

>99.99

Turbidity

0.5 NTU

10.7 NTU

11 ± 1 NTU

0.49 NTU

0.31 NTU

95.2

97.09

 

 

 

 

 

 

 

 

Lindane

0.0002 mg/L

0.002 mg/L

0.002 ± 10%

< 0.0001mg/L

0.000 mg/L

96.50%

98.72%

 

 

 

 

 

 

 

 

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).

It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter’s rated life is used, the yellow (Order) light comes on. When 100% of the filter’s rated life is used, the red (Replace) light comes on, and it is recommended that you replace the filter. Use replacement cartridge 67003523, part #4396395. 2005 suggested retail price of $49.99 U.S.A./ $65.95 Canada. Prices are subject to change without notice.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Refer to the back cover or “Accessories” section for the Manufacturer’s name, address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

35 - 100 psi (241 - 689 kPa)

Water Temperature

33° - 100°F (1° - 38° C)

Service Flow Rate

0.78 gpm (2.9 L/min.) @ 60 psi.

*Class I particle size: >0.5 to <1 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. ††Fibers greater than 10 um in length

Based on the use of Cryptosporidium parvum oocysts

®NSF is a registered trademark of NSF International.

22

Image 22
Contents BOTTOM-MOUNT Refrigerator 12828135Table of Contents Table DES MatièresRefrigerator Safety Before You Throw Away Your Old Refrigerator or FreezerUnpack the Refrigerator Installation InstructionsClean Before Using Location RequirementsWater Supply Requirements Electrical RequirementsConnect the Water Supply Base Grille RefrigeratorDoorsFreezer Drawer Wire Harness Top HingesStyle 1 Front leveling Adjustthe DoorWater System Preparation Style 2 Front and rear levelingNormal Sounds Refrigerator USEOpeningand Closing Doors Usingthe Controls Ensuring Proper Air CirculationDoor Alarm Additional Control Center Features Max CoolOptimIce Feature Holiday ModeWater Filtration System Water DispenserWaterFilter Status Light Ice MakerCrisper and Crisper Cover Refrigerator ShelvesCrisper HumidityControl Temperature-Controlled DrawerUtilityor Egg Bin Door Features Freezer FeaturesRefrigerator Care Changing the Refrigerator Light Bulb Power InterruptionsChanging the Light Bulb Changing the Freezer Light BulbTroubleshooting Vacation and MovingCareOff-taste, odor or gray color in the ice Refrigerator seems to make too much noiseIce maker is not producing ice or not enough ice Water dispenser will not operate properlyAssistance or Service U.S.AReplacement Water Filter AccessoriesStainless Steel Cleaner & Polish Water Filter CertificationsProduct Data Sheets Application Guidelines/Water Supply ParametersKitchenaid Refrigerator Warranty ONE Year Limited WarrantySécurité DU Réfrigérateur Avant de jeter votre vieux réfrigérateur ou congélateurDéballage du réfrigérateur Instructions D’INSTALLATIONEmplacement d’installation Enlèvement des matériaux d’emballageSpécifications de l’alimentation en eau Spécifications électriquesRaccordement dela canalisation deau Achever l’installation Raccordement au réfrigérateurGrille de la base Portes du réfrigérateurTiroir du congélateur Remplacement de les portes et des charnièresRéinstallation du tiroir du congélateur Enlèvement du tiroir du congélateurDémontage et réinstallation de la porte Charnières supérieuresStyle 1 Nivellement avant Ajustementde la portePréparation du système d’eau Style 2 Nivellement avant et arrièreSonsnormaux Utilisation DU RéfrigérateurOuverture et fermeture des portes Ajustement des réglages de commande Utilisation des commandesCommandes de température Pour s’assurer d’une circulation d’air AppropriéeTemp Alarm alarme de dépassement de température Holiday Mode mode vacancesPour ajuster les réglages de température Distributeur d’eau Témoins lumineux de létatdu filtre à eauSystème de filtration d’eau intérieur Machine à glaçonsTablettesdu réfrigérateur Caractéristiques DU RéfrigérateurBac à légumeset couvercle Réglage de l’humidité dansle bac à légumes Tiroir à température contrôléeCaractéristiques DU Congélateur Caractéristiques DE LA PorteEntretien DU Réfrigérateur Remplacement de l’ampoule d’éclairageRemplacement de lampoule du compartiment de réfrigération NettoyageEntretien avant les vacances ou lors ’un déménagement Remplacement de lampoule du compartiment de congélationPannes de courant DéménagementDépannage Le débit d’eau du distributeur diminue beaucoup Mauvais goût, odeur ou couleur grise des glaçonsLe distributeur d’eau ne fonctionne pas bien ’eau coule du distributeurLes portes sont difficiles à ouvrir La cloison entre les deux sections est tièdeLa température est trop tiède Les portes ne se ferment pas complètementAssistance OU Service AccessoiresFeuilles DE Données SUR LE Produit Système de filtration d’eau intérieurGarantie DU Réfrigérateur Kitchenaid Garantie Limitée DE UN AN12828135