L.P. Gas:
No attempt shall be made to convert the cooktop from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. Conversion must be done by a qualified service technician. To convert to L.P. gas, use L.P. gas conversion kit part no. 8284934. The parts for this kit are in the literature package supplied with cooktop.
D.Provide a gas supply line of 3/4" rigid pipe to the cooktop location. A smaller size pipe on long runs may result in insufficient gas supply.
E.If local codes permit, use a flexible stainless steel tubing gas connector,
shutoff valve “open” position
to cooktop
F.The supply line shall be equipped with an approved shutoff valve. This valve should be located in the same room as the cooktop and should be in a location that allows ease of opening and closing. Do Not block access to the shutoff valve. The valve is for turning on or shutting off gas to the appliance.
G.If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an
H.The regulator must be checked at a minimum
NATURAL GAS:
Set pressure 5 inches (12.7 cm) W.C. Supply pressure
L.P. GAS:
Minimum pressure 10 inches (25.4 cm) W.C.
Supply pressure 14 inches (35.5 cm) W.C.
I.Line pressure testing: Testing above 1/2 psi (3.5 kPa) or 14 inches (35.5 cm) W.C. (gauge) The cooktop and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psig (3.5kPa).
Testing below 1/2 psi (3.5 kPa) or 14 inches (35.5 cm) W.C. (gauge) or lower
The cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
Electrical requirements
WARNING
Electrical Shock Hazard
Plug into a grounded
Do not remove ground prong. Do not use an adapter.
Failure to follow these instructions can result in death, fire, or electrical shock.
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
Check with a qualified electrician if you are not sure whether the cooktop is properly grounded.
Do Not ground to a gas pipe.
A
Electronic ignition systems operate within wide voltage limits, but proper ground and polarity are necessary. In addition to checking that the outlet provides
Important: This cooktop is equipped with an electronic ignition system that will not operate if plugged into an outlet that is not properly polarized.
This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the current CSA standard C22.1. Canadian Electrical Code Part 1*.
Recommended ground method
For your personal safety, this cooktop must be grounded. This cooktop is equipped with a
ground prong
power supply cord