1.5 TECHNICAL DATA
ENERGY CONSUMPTION ventilated oven only function (CENELEC HD 376 norms) |
|
To reach 200°C | 0,35 kWh |
To maintain a temperature of 200°C for an hour | 1,15 kWh |
Total consumption | 1,5 kWh |
• OUTPUT POWER - MICROWAVE: 1000 W (IEC705) |
|
For additional data, consult the data plate placed on the front side of the appliance. |
|
This appliance complies to E.E.C. directive no. 89/336 and 92/31 regarding Electromagnetic Compatibility, and to directive 89/109/E.E.C. regarding materials which come into contact with food.
OUTPUT POWER
The microwave output power is written on the rating plate placed on the control panel (see “MICRO OUTPUT”). When you consult the tables, always look up your oven’s output power. It will be useful also when you are consulting cook- books intended for use with microwave ovens.
ONLY FOR SOME MODELS: The microwave output power is also indicated inside this simbol, placed on the door.
(ONLY FOR U.K.) The letter indicates the heating category to which your oven belongs: some
1.6 INSTALLATION AND ELECTRICAL CONNECTION
1)Remove all the accessories and wash them.
2)Clean the inside with a soft, damp cloth.
3)Check that there is no damage as a result of transportation, and in particular that the door opens and clos- es properly.
4)Place the support (I) in the centre of the circular groove and fix the turntable (H) to it. The spindle (D) should be inserted in the corresponding groove in the centre of the turntable.
5)After the installation has been performed, the power supply cable and the power socket must be easy to access.
6)Only a qualified electrician may install or relocate a socket outlet.
7)Only connect the appliance to a power socket with a power capacity of at least 16A. Also make sure that the main switch installed in your home has a minimum power capacity of 16A in order to avoid it suddenly trip- ping while the oven is on.
8)Before use, check that the power supply voltage is the same as the one shown on the rating label and that the power outlet is properly earthed: the manufacturer disclaims any liability in the event of
ELECTRICAL CONNECTION (U.K. ONLY)
A)If your appliance comes fitted with a plug, it will incorporate a 13 Amp fuse. If it does not fit your socket, the plug should be cut off from the mains lead, and an appropriate plug fitted, as below.
WARNING: Very carefully dispose of the cut off plug after removing
the fuse: do not insert in a 13 Amp socket elsewhere in the house as this could cause a shock hazard.
With alternative plugs not incorporating a fuse, the circuit must be protected by a 15 Amp fuse.
WARNING - THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in the mains lead are coloured in accordance with the following
code: |
|
Green and yellow: | Earth |
Blue: | Neutral |
Brown: | Live |
If the plug is a
B)If your appliance is not fitted with a plug, please follow the instructions provided below:
As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
The green and yellow wire must be connected to the terminal in the plug
marked with the letter E or the earth symbol or coloured green or green and yellow.
The blue wire must be connected to the terminal marked with the letter N or coloured black.
The brown wire must be connected to the terminal marked with the letter L or coloured red.
10