Wells WVOC-4HS, WVOC-4HC, WVOC-4HF operation manual Ventilator Operation, PRE-FILTER Element

Page 15

VENTILATOR OPERATION

1.Press the VENTILATOR POWER switch to ON. The green VENTILATOR POWER light will glow and the blower fan will start. After a short time, if all filters are sensed as being in position and not clogged, the cooking appliance will be energized. The roll warmer is energized at all times.

During normal operation, the VENTILATOR POWER light will be the only light glowing on the upper control panel.

2.If the amber CHECK FILTER light glows, one or more filter elements is out of position. Check the GREASE BAFFLE, PRE-FILTER and FILTER PACK for proper installation in their respective positions. Grease baffle and filter pack position are sensed by mechanical switches. Pre-filter position is sensed by a vacuum switch.

3.When the amber REPLACE PRE-FILTERlight glows, the pre-filter is nearing the end of its service life. Replace the disposable

PRE-FILTER ELEMENT.

4.When the amber REPLACE FILTER PACK light illuminates, the HEPA / Charcoal filter pack is nearing the end of its service life. Replace the FILTER PACK.

Note: The REPLACE PRE-FILTER and REPLACE FILTER PACK lights are a warning that the indicated filter is near the end of its service life. The appliance will continue to operate for a period of time after the light glows to allow continued operation through a peak period. However, the indicated filters must be replaced within a reasonably short time period or they will clog and shut down electrical power to the cooking appliance . The ventilator blower will continue to run.

5.When the red SERVICE REQUIRED light glows, either the pre-filter or filter pack (or both) is clogged and can no longer pass sufficient air to allow further operation. The ventilator fan continues to run, but the cooking appliance is shut down until the underlying clogged filter situation has been corrected. This can occur when neither CHANGE...FILTER indicator light is lit, if both pre-filter and filter pack are marginal. Replacing both the pre-filter and the filter pack will remedy the situation.

Note: Replacing the pre-filter, even though not very dirty, will often extend the service life of the more expensive filter pack.

Reset the unit by turning the VENTILATOR POWER switch to OFF, then back ON.

6.A failure of incoming electrical power will cause a shut down of the unit. After power is restored, reset the unit by turning the VENTILATOR POWER switch to OFF, then back ON.

NOTE: Oven, griddle and hotplate will not operate unless the fire suppression system is charged, and the ventilator section is operating

OPERATION

CAUTION:

Hot Surface

Exposed surfaces can be hot to the touch and may cause burns.

Fig. 10 Ventilator Indicator and Warning Lights

13

Image 15
Contents Important do not Discard this Manual 506Limited Warranty Statement Table of Contents SpecificationsIntroduction Features & Operating Controls Description Comment Ventilator SectionFeatures & Operating Controls Ventilator Section Controls Cooktop Section ControlsConvection Oven Section Controls Electric Shock hazard Precautions and General InformationSTD Operational NotesInstallation SetupUnpacking & Inspection Electric Shock Hazard Service Technician Installation NotesElectrical Installation This is Responsibility InstallerFire Suppression System Installation Fire HazardAuthority Having Jurisdiction Filter Installation Filters InstallationDo not Operate Unless Grease CUP is Installed Grease Trough and Grease CUP InstallationHotplate Drip PAN Installation Spiral Heating Elements only Oven Rack InstallationVentilator Operation OperationPRE-FILTER Element Pastries Suggested Cooking TimesConvection Oven Product Temp Time Number Minutes Racks Bread ProductsManual Cook Mode Program Cook ModeConvection Oven Operating Instructions Burn Hazard Temperature Offset ModeCooking with Your Hotplate Hotplate Operating InstructionsConvection Oven Cleaning Instructions Cleaning InstructionsTools Hotplate Cleaning InstructionsPrecautions FrequencyVentilator Section Cleaning Instructions CleaningPreparation Hotplate will not Heat Troubleshooting SuggestionsConvection Oven Controller Error Codes No Part of the Appliance will HeatMaintenance Instructions FAN CleaningLatch Adjustment Hinge Adjustment Maintenance InstructionsTemperature Calibration Fire Hazard Maintenance SchedulesPage Page Ansul Health Hazards Page Parts & Service Description Service
Related manuals
Manual 34 pages 8.39 Kb

WVOC-4HF, WVOC-4HC, WVOC-4HS specifications

The Wells WVOC-4HS is a cutting-edge vaporizer designed to meet the needs of various industrial applications, particularly in the pharmaceutical and chemical sectors. Known for its exceptional performance and reliability, the WVOC-4HS stands out with its innovative features and advanced technologies.

One of the main features of the Wells WVOC-4HS is its high-efficiency heating system. Utilizing advanced thermal conduction methods, this vaporizer ensures rapid and uniform heating of the material, minimizing any potential degradation while maximizing output. Its robust design supports a variety of materials, providing versatility in application.

The WVOC-4HS is equipped with a user-friendly digital control interface that allows for precise temperature regulation and monitoring. This feature is crucial in industries where specific temperature thresholds must be maintained for optimal safety and efficacy. The control system can be integrated with existing automated systems, enabling seamless operation and consistent performance.

Another important characteristic of the Wells WVOC-4HS is its safety protocols. The design incorporates multiple safety features, including over-temperature protection and pressure relief valves. These systems are designed to prevent accidents and ensure a safe operating environment for all personnel.

The vaporizer’s construction is also noteworthy, as it is made from high-grade, corrosion-resistant materials. This not only increases the longevity of the device but also ensures that it can withstand various chemicals, making it a dependable choice for rigorous industrial use. This durable build quality is essential for maintaining performance in demanding environments.

Additionally, the Wells WVOC-4HS boasts a compact design that allows for easy installation and integration into existing setups. Its lightweight architecture aids in reducing space requirements without compromising on performance.

In summary, the Wells WVOC-4HS is a reliable and efficient vaporizer that combines high-efficiency heating, advanced digital controls, robust safety features, and durable construction. Its versatility makes it an ideal choice for industries that require precise vaporization processes, ensuring optimal performance in every application. Whether used in pharmaceutical production or chemical processing, the WVOC-4HS exemplifies technological advancement and reliability in vaporization.