CLEANING INSTRUCTIONS (continued)

CAUTION:

Electric Shock

Hazard

Disconnect appliance from electric power before cleaning.

CAUTION:

Hot Surface

Exposed surfaces can be hot to the touch

and may cause burns. Allow appliance to cool before cleaning.

IMPORTANT:

Never allow PRE-FILTER or FILTER PACK to get wet. DO NOT wash either of these two filters. Washing these filters will ruin them and cause the appliance to shut-down.

IMPORTANT:

DO NOT spill or pour water into controls, control panel, wiring or coil-type hotplate elements. Damage to internal components will occur. Damage to internal components from water damage is not covered by warranty.

VENTILATOR SECTION CLEANING INSTRUCTIONS

PREPARATION

Disconnect appliance from electric power

Allow to cool before cleaning

FREQUENCY Weekly

TOOLS

Warm water and a mild detergent

Soft clean cloth or sponge

Bristle brush

Container for disposal of grease

CLEANING

Disconnect appliance from electric power Allow to cool before cleaning

Remove the grease baffle, pre-filter assembly, grease trough and grease cup. Empty the grease trough and grease cup.

Remove the pre-filter from the filter frame. Wash and rinse the filter frame ONLY.

Wash and rinse the grease baffle, grease trough and grease cup in a sink or dishwasher using mild detergent and warm water. Allow to air dry.

Reinsert the pre-filter into the filter frame. Reinstall the pre-filter, grease baffle, grease trough and grease cup.

Procedure is complete

IMPORTANT:

DO NOT use steel wool or metal implements to clean drawers or cabinet surfaces.

20

Image 22
Contents 506 Important do not Discard this ManualLimited Warranty Statement Specifications Table of ContentsIntroduction Features & Operating Controls Ventilator Section Description CommentFeatures & Operating Controls Cooktop Section Controls Ventilator Section ControlsConvection Oven Section Controls Precautions and General Information Electric Shock hazardOperational Notes STDSetup InstallationUnpacking & Inspection This is Responsibility Installer Service Technician Installation NotesElectrical Installation Electric Shock HazardFire Hazard Fire Suppression System InstallationAuthority Having Jurisdiction Filters Installation Filter InstallationOven Rack Installation Grease Trough and Grease CUP InstallationHotplate Drip PAN Installation Spiral Heating Elements only Do not Operate Unless Grease CUP is InstalledOperation Ventilator OperationPRE-FILTER Element Bread Products Suggested Cooking TimesConvection Oven Product Temp Time Number Minutes Racks PastriesProgram Cook Mode Manual Cook ModeConvection Oven Operating Instructions Temperature Offset Mode Burn HazardHotplate Operating Instructions Cooking with Your HotplateCleaning Instructions Convection Oven Cleaning InstructionsFrequency Hotplate Cleaning InstructionsPrecautions ToolsCleaning Ventilator Section Cleaning InstructionsPreparation No Part of the Appliance will Heat Troubleshooting SuggestionsConvection Oven Controller Error Codes Hotplate will not HeatFAN Cleaning Maintenance InstructionsLatch Adjustment Maintenance Instructions Hinge AdjustmentTemperature Calibration Maintenance Schedules Fire HazardPage Page Ansul Health Hazards Page Description Service Parts & Service
Related manuals
Manual 34 pages 8.39 Kb

WVOC-4HF, WVOC-4HC, WVOC-4HS specifications

The Wells WVOC-4HS is a cutting-edge vaporizer designed to meet the needs of various industrial applications, particularly in the pharmaceutical and chemical sectors. Known for its exceptional performance and reliability, the WVOC-4HS stands out with its innovative features and advanced technologies.

One of the main features of the Wells WVOC-4HS is its high-efficiency heating system. Utilizing advanced thermal conduction methods, this vaporizer ensures rapid and uniform heating of the material, minimizing any potential degradation while maximizing output. Its robust design supports a variety of materials, providing versatility in application.

The WVOC-4HS is equipped with a user-friendly digital control interface that allows for precise temperature regulation and monitoring. This feature is crucial in industries where specific temperature thresholds must be maintained for optimal safety and efficacy. The control system can be integrated with existing automated systems, enabling seamless operation and consistent performance.

Another important characteristic of the Wells WVOC-4HS is its safety protocols. The design incorporates multiple safety features, including over-temperature protection and pressure relief valves. These systems are designed to prevent accidents and ensure a safe operating environment for all personnel.

The vaporizer’s construction is also noteworthy, as it is made from high-grade, corrosion-resistant materials. This not only increases the longevity of the device but also ensures that it can withstand various chemicals, making it a dependable choice for rigorous industrial use. This durable build quality is essential for maintaining performance in demanding environments.

Additionally, the Wells WVOC-4HS boasts a compact design that allows for easy installation and integration into existing setups. Its lightweight architecture aids in reducing space requirements without compromising on performance.

In summary, the Wells WVOC-4HS is a reliable and efficient vaporizer that combines high-efficiency heating, advanced digital controls, robust safety features, and durable construction. Its versatility makes it an ideal choice for industries that require precise vaporization processes, ensuring optimal performance in every application. Whether used in pharmaceutical production or chemical processing, the WVOC-4HS exemplifies technological advancement and reliability in vaporization.