FILTERS INSTALLATION

1.FILTER PACK: Ships installed in the hood. If the FILTER PACK is not in position, the CHECK FILTERS indicator will light.

If the FILTER PACK becomes clogged, the REPLACE FILTER PACK indicator will glow.

To install the FILTER PACK: Position the filter pack with the charcoal portion UP. Slide the filter pack toward the rear of the unit until it contacts the guides on the back panel. Push the filter pack UP into the upper opening until it rests firmly against the filter pack seal. When up in position, holder clips can be snapped over wall ledge on each side. To remove FILTER PACK: Grasp both holder clips and pull INWARD until the clips clear the sidewall ledge. Then, pull the filter pack down and out.

2.PRE-FILTER: The PRE-FILTER ships in the FILTER FRAME. If the PRE-FILTER is not in position, or if the PRE-FILTER is not in the FILTER FRAME, the CHECK FILTERS indicator will light. If the PRE-FILTER becomes clogged, the REPLACE PRE-FILTERindicator will glow.

To install the PRE-FILTER: Pay attention to the air flow markings. The AIR FLOW arrow will point away from the installer. Slide the assembly up into the front opening, behind the upper filter rail.

While pressing slightly against the bottom of the assembly, pull the FILTER HANDLE toward you so as to engage the FILTER HOOK over the lip of the top filter rail. Then lower and seat the assembly into the top indentation of the lower filter rail.

3.GREASE BAFFLE: If the GREASE BAFFLE is not in place, the CHECK FILTERS indicator will glow.

To install the GREASE BAFFLE: Slide the grease baffle up into the indentation of the upper filter rail, then lower and seat it into the bottom indentation of the lower filter rail. Pull toward you and downward to verify the GREASE BAFFLE is properly seated in the lower frame rail.

NOTE:

The GREASE BAFFLE and FILTER PACK activate mechanical switches, and the PRE-FILTER activates a vacuum switch, to verify that the filter elements are in their proper positions.

All filter elements must be properly installed or the cooktop will not be energized. Also, the CHECK FILTERS indicator will light.

IMPORTANT:

The filter hook prevents the PRE-FILTER from being drawn in during operation. After installation, press against the top of the filter frame to verify proper engagement of the filter hook over the lip of the top filter rail.

IMPORTANT: Protect the surface of ceramic cooktops from dam- age in the event a filter is accidentally dropped.

SEAL

FILTER PACK

HOLDER CLIP CLIPS ONTO LEDGE

OFUNIT

FILTER PACK

WALL

POSITION

SWITCH

 

FILTER PACK

 

SEAL

FLOW

FILTER PACK

HOLDER CLIP

 

AIR

GREASE BAFFLE

POSITION

 

SWITCH

 

PRE-FILTER

 

ASSEMBLY

 

GREASE

 

BAFFLE

 

GREASE

 

TROUGH

 

GREASE

 

CUP

PRE-FILTER

NOTE: AIR FLOW ARROW

POINTS AWAY FROM INSTALLER WHEN PROPERLY INSTALLED

FILTER HOOK

 

 

R

 

 

 

E

 

 

T

 

 

FILTER

IL

 

 

 

-F

 

 

 

HOOK

E

 

 

 

R

 

 

 

 

P

 

 

 

 

FILTER

RAIL

FILTER HANDLE

FILTER FRAME

NOTE: PRE-FILTER IS SENSED

AS BEING IN POSITION BY THE

PRESSURE DROP ACROSS IT.

Fig. 7 Filter Installation

11

Image 13
Contents Important do not Discard this Manual 506Limited Warranty Statement Specifications Table of ContentsIntroduction Features & Operating Controls Description Comment Ventilator SectionFeatures & Operating Controls Cooktop Section Controls Ventilator Section ControlsConvection Oven Section Controls Electric Shock hazard Precautions and General InformationSTD Operational NotesSetup InstallationUnpacking & Inspection Electrical Installation Service Technician Installation NotesThis is Responsibility Installer Electric Shock HazardFire Hazard Fire Suppression System InstallationAuthority Having Jurisdiction Filter Installation Filters InstallationHotplate Drip PAN Installation Spiral Heating Elements only Grease Trough and Grease CUP InstallationOven Rack Installation Do not Operate Unless Grease CUP is InstalledOperation Ventilator OperationPRE-FILTER Element Convection Oven Product Temp Time Number Minutes Racks Suggested Cooking TimesBread Products PastriesProgram Cook Mode Manual Cook ModeConvection Oven Operating Instructions Burn Hazard Temperature Offset ModeCooking with Your Hotplate Hotplate Operating InstructionsConvection Oven Cleaning Instructions Cleaning InstructionsPrecautions Hotplate Cleaning InstructionsFrequency ToolsCleaning Ventilator Section Cleaning InstructionsPreparation Convection Oven Controller Error Codes Troubleshooting SuggestionsNo Part of the Appliance will Heat Hotplate will not HeatFAN Cleaning Maintenance InstructionsLatch Adjustment Hinge Adjustment Maintenance InstructionsTemperature Calibration Fire Hazard Maintenance SchedulesPage Page Ansul Health Hazards Page Parts & Service Description Service
Related manuals
Manual 34 pages 8.39 Kb

WVOC-4HF, WVOC-4HC, WVOC-4HS specifications

The Wells WVOC-4HS is a cutting-edge vaporizer designed to meet the needs of various industrial applications, particularly in the pharmaceutical and chemical sectors. Known for its exceptional performance and reliability, the WVOC-4HS stands out with its innovative features and advanced technologies.

One of the main features of the Wells WVOC-4HS is its high-efficiency heating system. Utilizing advanced thermal conduction methods, this vaporizer ensures rapid and uniform heating of the material, minimizing any potential degradation while maximizing output. Its robust design supports a variety of materials, providing versatility in application.

The WVOC-4HS is equipped with a user-friendly digital control interface that allows for precise temperature regulation and monitoring. This feature is crucial in industries where specific temperature thresholds must be maintained for optimal safety and efficacy. The control system can be integrated with existing automated systems, enabling seamless operation and consistent performance.

Another important characteristic of the Wells WVOC-4HS is its safety protocols. The design incorporates multiple safety features, including over-temperature protection and pressure relief valves. These systems are designed to prevent accidents and ensure a safe operating environment for all personnel.

The vaporizer’s construction is also noteworthy, as it is made from high-grade, corrosion-resistant materials. This not only increases the longevity of the device but also ensures that it can withstand various chemicals, making it a dependable choice for rigorous industrial use. This durable build quality is essential for maintaining performance in demanding environments.

Additionally, the Wells WVOC-4HS boasts a compact design that allows for easy installation and integration into existing setups. Its lightweight architecture aids in reducing space requirements without compromising on performance.

In summary, the Wells WVOC-4HS is a reliable and efficient vaporizer that combines high-efficiency heating, advanced digital controls, robust safety features, and durable construction. Its versatility makes it an ideal choice for industries that require precise vaporization processes, ensuring optimal performance in every application. Whether used in pharmaceutical production or chemical processing, the WVOC-4HS exemplifies technological advancement and reliability in vaporization.