Whirlpool GZ7930XGS0 installation instructions Before you start, Mobile home installation

Page 2

Before you start...

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING”. These words mean:

DANGER

You can be killed or seriously injured if you don’t immediately follow instructions.

WARNING

You can be killed or seriously injured if you don’t follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

IMPORTANT: Observe all governing codes and ordinances.

Failure to meet codes and ordinances could lead to fire or electrical shock.

Proper installation is your responsibility. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with the installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the front of the downdraft vent above the wiring box cover.

Check location where downdraft vent will be installed. The location should be away from strong draft areas, such as windows, doors and strong heating vents or fans. Before making countertop cutout, check that downdraft vent and cooktop location will clear cabinet walls, backsplash, and rear wall studs inside cabinet.

Mobile home installation

The installation of this downdraft vent system must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the Standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local codes.

All openings in the wall or floor where retractable downdraft vent is to be installed must be sealed.

Electrical ground is required. See “Electrical requirements,” page 3.

When installing downdraft vent, the cabinet drawer will need to be removed and the drawer front installed permanently to cabinet.

NOTE: Downdraft vent is installed directly behind the cooktop. Install downdraft vent first.

Cabinet construction: Downdraft vent is designed for use in a cabinet with a depth of 24"

(61 cm). Some installations require a countertop deeper than 25" (63.5 cm). See chart on page 5. The maximum depth of the overhead cabinet is 13" (33 cm). Overhead cabinets installed at either side of the downdraft vent must be 18" (45.7 cm) above the cooking surface.

See cooktop Installation Instructions before making any cutouts and for the minimum distance between the front edge of the countertop and front edge of cooktop. The minimum horizontal distance between the overhead cabinets is the same as the width of the installed downdraft vent.

When installing a 36" (91.4 cm) retractable downdraft vent with “Create-A-Cooktop” modules, the optional support must be installed on the front of the downdraft vent. See installation steps for details.

Parts supplied for installation:

1 top trim

2 end caps

2 lower support legs

2 overcounter support brackets

2 undercounter mounting brackets

1 bag of fasteners

1 metal cover

1 backdraft damper

literature package

optional support and two screws (36" (91.4 cm) models only

Parts needed for installation:

2 U.L.- or C.S.A.-listed 1/2" (12.7 mm) conduit connectors (3 are required if the exterior-mounted vent motor

is used.)

1 wall cap for interior-mounted motor

vent system

power supply cable

wiring cable for optional remote blower kit.

Tools needed for installation:

safety glasses

gloves

jig or keyhole saw

drill with 1/8" drill bit

pencil

measuring tape

flat-blade screwdriver

Phillips screwdriver

3/8" (9.5 mm) nut driver or ratchet

level

pliers

metal snips

wire stripper or utility knife

caulking gun and weatherproof caulk

duct tape

2

Image 2
Contents Installation Instructions Use and Care Guide Mobile home installation Before you startElectrical requirements Product dimensions Cabinet dimensionsCountertop cutout dimensions KGCS105G KIRD801HSS KIRD802HSSMaximum length of vent system Vent systemRequirements Determining the length of system you needRecommended standard FittingsBracket for rear venting Kird and Ykird 10 25.4 cm round vent systemRecommended standard Fittings Disconnect power Operating downdraft vent CleaningUse and Care Information Accessories Vent System WarrantyRequesting Assistance or Service in U.S.A Requesting Assistance or Service in CanadaInstructions d’installation et Avant de commencer Alimentation électrique Dimensions du produit Dimensions du placardModèle de 76,2 cm 30 po Pour certains modèles, on doit Prescriptions concernant le système d’évacuation Détermination de la longueur nécessaire du systèmeRecommandés Circuit d’évacuation de conduit rond, diam ,2 cm 6 poAvertissement Longueur maximale du Conduit d’évacuationRaccords standard recommandés Bouton de commande du ventilateur Embout Nettoyage Information d’utilisation et entretienFonctionnement du système d’aspiration par le bas Accessoires Garantie du système de ventilationDemande d’assistance ou de service au Canada Pour plus d’assistance