Whirlpool GZ7930XGS0 installation instructions Disconnect power

Page 11

10. Insert retractable downdraft vent into countertop cutout. Two people are recommended to support the weight of the downdraft vent during lifting. Position downdraft vent so it is centered in cutout and parallel to edge of cutout. Check that downdraft vent is vertical. Then attach lower support legs to cabinet floor with screws.

When attaching undercounter bracket to underside of countertop, make sure that the screw length will not go through countertop when tightened.

11. Attach one undercounter mounting bracket on front upper right corner of downdraft vent with slot over vent mounting hole and flange against countertop. Attach other bracket to left side of downdraft vent. Carefully drill starter holes through undercounter mounting brackets into underside of countertop. Insert appropriate length screws into holes and tighten brackets to countertop.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Connect ground wire to green ground screw in terminal box.

Failure to do so can result in death or electrical shock.

12. Disconnect power.

vent box knockout

wiring box cover

green

green

ground

ground

wire

screw

conduit connector

13. Feed the power supply cable through the conduit connector and into wiring box. Connect the white wires together with a twist-on wire connector. Connect the black wires together with a twist-on wire connector. Attach the green (or green and yellow) ground wire to eyelet with green ground screw and tighten screw. Replace wiring box cover.

green

 

ground

green

screw

 

ground

 

wire

 

exterior-mounted

 

vent motor wiring

14. Remove vent box knockout and install conduit connector.

Feed exterior-mounted vent motor wiring through conduit connector.

IMPORTANT: Do not wire the exterior vent motor black and white wires into the wiring box. Wires must be connected as shown. Connect the white wires together with a twist-on wire connector. Connect the black wires together with a twist-on connector.

Attach ground wire to eyelet with green ground screw and tighten screw.

Tighten conduit connector clamp screws.

15. Reconnect power.

microswitches behind filters ON/OFF button

blower control knob

filter or filters

 

depending on

end cap

model

16. Push and hold for a few seconds the button on the top of the downdraft vent. Retractable section of downdraft vent will rise and blower will start. Position the top trim over the retractable section and snap trim into place.

17. Turn the control knob on side of vent to check the operation and speed of blower.

If blower does not operate:

Check that filter or filters are pressed in as far as they will go.

Check that circuit breaker is not tripped or house fuse blown.

Reconnect power. Check that wire connections have been made correctly.

18. Connect vent to blower. Position vent to avoid wall studs and floor joists. Complete all vent work. Use duct tape to seal all joints. Vertical vent for wall- mounted installations should pitch down slightly toward the vent to allow moisture to run outside.

19. Install cooktop according to manufacturer’s instructions. Check that rear of cooktop overlaps edge of retractable downdraft vent by 3/8" (9.5 mm).

To get the most efficient

use from your new

retractable downdraft vent,

read the Use and Care Information section on page 12.

Keep Installation Instructions

and Use and Care

Information close by for

easy reference.

11

Image 11
Contents Installation Instructions Use and Care Guide Before you start Mobile home installationElectrical requirements Cabinet dimensions Product dimensionsKGCS105G KIRD801HSS KIRD802HSS Countertop cutout dimensionsDetermining the length of system you need Vent systemRequirements Maximum length of vent systemFittings Recommended standardBracket for rear venting 10 25.4 cm round vent system Kird and YkirdRecommended standard Fittings Disconnect power Operating downdraft vent CleaningUse and Care Information Vent System Warranty AccessoriesRequesting Assistance or Service in Canada Requesting Assistance or Service in U.S.AInstructions d’installation et Avant de commencer Alimentation électrique Dimensions du placard Dimensions du produitModèle de 76,2 cm 30 po Pour certains modèles, on doit Détermination de la longueur nécessaire du système Prescriptions concernant le système d’évacuationCircuit d’évacuation de conduit rond, diam ,2 cm 6 po RecommandésAvertissement Conduit d’évacuation Longueur maximale duRaccords standard recommandés Bouton de commande du ventilateur Embout Nettoyage Information d’utilisation et entretienFonctionnement du système d’aspiration par le bas Garantie du système de ventilation AccessoiresPour plus d’assistance Demande d’assistance ou de service au Canada