Whirlpool GZ7930XGS0 installation instructions Bracket for rear venting

Page 8

bracket for rear venting

WARNING

12. Disconnect power.

d. Remove screws attaching brackets to each side of blower. Reposition brackets on blower as shown. Then reinstall screws.

e. Reinstall blower in blower box with mouth of blower pointing

Excessive Weight Hazard

Use two or more people to move and install downdraft vent.

Failure to do so can result in back or other injury.

10. Insert downdraft vent into countertop cutout. Two people are recommended to support the weight of the downdraft vent

wiring box

green ground screw

conduit

out open side of blower box. Secure blower to blower box with 6 Phillips-head screws.

NOTE: Square metal frame attached to mouth of blower must be installed for proper operation.

f. Attach metal cover from parts bag over down-venting knockout in blower box. Remove rear knockout cover on back of vent base.

g. Reconnect blower wiring cable. Secure wiring cable in 2 black plastic clips inside vent base.The wiring cable must be properly secured in the 2 clips (see step b.) Reattach blower box to downdraft vent base with 4 hex nuts.

during lifting. Position downdraft vent so it is centered in cutout and parallel to edge of cutout. Check that downdraft vent is level vertically. Then fasten lower support legs to cabinet floor with screws.

When attaching undercounter bracket to underside of countertop, make sure that the screw length will not go through countertop when tightened.

11. Attach one undercounter bracket on front upper right corner of downdraft vent with slot over vent mounting hole and flange against countertop. Attach other bracket to left side of downdraft vent. Carefully drill starter holes through undercounter mounting brackets into underside of countertop. Insert appropriate length screws into holes and tighten brackets to countertop.

connector

13. Remove required knockout and install conduit connector. Feed the power supply cable through the conduit connector and into the wiring box. Connect the white wires together with a twist-on wire connector. Connect the black wires together with a twist-on wire connector. Attach the green (or green and yellow) ground wire to eyelet with green ground screw. Tighten the conduit connector clamp screws. Replace the wiring box cover.

14. Reconnect power.

microswitches behind filters.

ON/OFF button

top trim

blower control knob

filter or filters

 

depending on

end cap

model

15.Push and hold for a few seconds the button on the top of the downdraft vent. Retractable

8. Attach backdraft damper over blower box knockout with 2 Phillips-head screws.

9. Remove the 2 Phillips-head screws attaching the wiring box cover. Determine which direction (rear or down) electrical connection will need to run from appliance wiring box. Remove rear or bottom knockout and install conduit connector.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Connect ground wire to green ground screw in terminal box.

Failure to do so can result in death or electrical shock.

section of downdraft vent will rise and blower will start. Position the top trim over the retractable section and snap trim into place.

8

Image 8
Contents Installation Instructions Use and Care Guide Mobile home installation Before you startElectrical requirements Product dimensions Cabinet dimensionsCountertop cutout dimensions KGCS105G KIRD801HSS KIRD802HSSVent system RequirementsMaximum length of vent system Determining the length of system you needRecommended standard FittingsBracket for rear venting Kird and Ykird 10 25.4 cm round vent systemRecommended standard Fittings Disconnect power Operating downdraft vent CleaningUse and Care Information Accessories Vent System WarrantyRequesting Assistance or Service in U.S.A Requesting Assistance or Service in CanadaInstructions d’installation et Avant de commencer Alimentation électrique Dimensions du produit Dimensions du placardModèle de 76,2 cm 30 po Pour certains modèles, on doit Prescriptions concernant le système d’évacuation Détermination de la longueur nécessaire du systèmeRecommandés Circuit d’évacuation de conduit rond, diam ,2 cm 6 poAvertissement Longueur maximale du Conduit d’évacuationRaccords standard recommandés Bouton de commande du ventilateur Embout Nettoyage Information d’utilisation et entretienFonctionnement du système d’aspiration par le bas Accessoires Garantie du système de ventilationDemande d’assistance ou de service au Canada Pour plus d’assistance