16. Turn the control knob on side of vent to check the operation and speed of blower.
If blower does not operate:
•Check that filter or filters are pressed in as far as they will go.
•Check that circuit breaker is not tripped or house fuse blown.
•Disconnect power. Check that wire connections have been made correctly.
•Reconnect power.
17. Connect vent system to blower. Vent system must end with a wall or roof cap. Use duct tape to seal all joints.
18. Install cooktop according to manufacturer’s instructions. Check that rear of cooktop overlaps edge of retractable downdraft vent by 3/8" (9.5 mm).
To get the most efficient use from your new retractable downdraft vent, read the Use and Care Information section on page 12.
Keep Installation Instructions
and Use and Care
Information close by for
easy reference.
Exterior-mounted vent motor
KIRD and YKIRD
MODELS ONLY
NOTE:
IMPORTANT: Exterior blower Model No. KPEU722M [1200 cfm (34.0 m3/3)] cannot be used with this retractable downdraft vent system.
Installation requirements
Island location
Roof venting
10" (25.4 cm) round vent
Maximum length of vent system
Vent | Length |
10" (25.4 cm) round | 40 ft. (12.2 m) |
|
|
It is recommended that you use round vent instead of rectangular vent, especially if elbows are required. If rectangular vent is required, it should be transitioned to 10" (25.4 cm) round vent as soon as possible.
Determining the length of system you need:
To calculate the length of system you need, add the equivalent feet for each duct piece that will be needed. See example for 10"
(25.4 cm) round vent system.
10" (25.4 cm) round vent system
Vent length is given as a general reference only. For a longer vent run, or smaller vent system, contact a qualified and trained vent installer. Check with local codes for makeup air requirements, if any.
For best performance, use no more
than three 90° elbows. If more than
(61 cm) of straight vent between any two elbows. Do not install two elbows together.
Maximum length = 40 ft. (12.2 m)
2 - 90 elbows | = 10 | ft. (3.05 m) |
10 ft. (3 m) straight | = 10 | ft. (3.05 m) |
|
|
|
Length of 10" |
|
|
(25.4 cm) system | = 20 ft. (6.1 m) |
NOTE: The
left vent | right vent | 9 |