Xantech mrc88 installation instructions Source Loop-Thru Connections

Page 16

Page: 16

Model MRC88

23.Source Loop-Thru Connections (8).

a)Audio Loop-Thru. Parallel Connection to Audio Inputs for connecting Audio Source to another MRC- 88 in Expanded Mode or to other local devices. This is not an active output.

b)Video Loop-Thru. Buffered Video Connection for connecting Input Video Source to another MRC-88 in Expanded Mode or to other local devices. NOTE: Since this is a Buffered video connection, this loop- thru is not active when POWER is removed from the MRC88

24.Zone Audio Inputs (8). 3.5mm Stereo Mini Phone Jack for Zone specific stereo audio Server Inputs. Zone Audio Inputs override rear panel, Source 1 connection. Allows each of the 8 Zones to have a dedicated Server Output by selecting Source 1 on keypad.

25.Zone Audio Pre-Amp Out (8). Gold-plated RCA Jacks for connecting Zone Audio Output to an external amplifier. For use with applications where either more power is required for Zone or passing to a Dolby Pro compatible receiver for theater quality audio in zone.

26.IR Emitters (1-8). 3.5mm Mono Mini Phone Jacks. These mini jacks are for the connection of IR emitters to control individually the eight source components. These jacks are “steerable” with Dragon Drop-IR™ Software for IR Routing and Priority Lockout. IR received from a Zone will be routed to the emitter port corresponding to the Zones active source selection. Can also be configured as 8 common emitter ports (ADVANCED only) (See: Section 5: Controller Options Programming).

27.IR Emitter (Common). 3.5mm Mono Mini Phone Jacks. Single Common IR Output that can be used to control devices such as Multi Zone Audio Server, motorized drapery systems, TV lifts and lighting systems or any other IR controlled component. IR Received from any Zones Keypad will be output the Common emitter port regardless of source selection.

28.Zone IR Out (8). 3.5mm Mono Mini Phone Jacks. IR received from a Zone will always be passed to the corresponding Zone IR output. This can be used to control Zone Specific components not located in the zone.

29. Com Port. DB9 RS232 Control Port allows full control from an external PC component of all Internal Amplifier Commands of the MRC88 Controller and the ability to trigger programmed IR Macros for control of devices connected to the Controllers emitter ports. The Com Port can also be used in the reverse to send ASCII/Hex commands OUT to control an external RS232 device directly from the MRC88 Keypad and/or handheld remote.

30.Expansion Port. DB15. Allows two MRC88’s to be connected together, via included Expansion Cable, to provide an 8 Source/16 Zone system with full control between units.

31.User Replaceable Fuse. 10 AMP 250 VAC, Slow Blow Fuse (Domestic version). 5 AMP 250 VAC, Time- Lag Fuse (European version).

32.AC Power Input. Standard IEC 3-Conductor AC Line Cord Receptacle for plug-in of a 3-conductor power line cord.

33.Grounding Screw. “Knurled Screw” provides a means for chassis connection to earth ground or to other Audio/Video products to aid in the reduction of system noise.

34.Power On/Off LED. This LED indicates the Main Power ON/OFF Condition of the MRC88 Controller.

© 2003 Xantech Corporation

Image 16
Contents Installation Instructions Safety Instructions Read Before Operating Equipment Not Expose this Appliance to Rain or MoistureTable of Contents Programming the Controller ADVANCED/EXPANDED Programming Section Model MRC88 Xantech Corporation General Information MRC88 system includes the following componentsModel MRC88 System Block Diagram System OverviewCONTROLLER/AMPLIFIER Features Keypad Features MRC88 CONTROLLER/AMPLIFIER Panel and Feature Descriptions MRC88 Front Panel Features and ConnectionsSystem Status Power-Up Mode Front PanelZone Status Active-Operational Mode MRC88 Rear Panel Features and Connections Source Component Input ConnectionsSource Loop-Thru Connections MRC88 Keypad Front Features MRC88 Keypad Feature DescriptionsMRC88 Keypad Model MRC88 Model MRC88 Keypad Rear Panel Features and Functions MRC88 Keypad Rear Features and ConnectionsInstallation Operation OUT-OF-THE-BOX PRE Test BASIC/ADVANCED/EXPANDEDKeep perforations on top cover free MRC88Obstructions Mounting and Installing the MRC88 Keypad ExpandedMRC88 Keypad mounting template Optional Keypad Back-Box for pre-install applications MRC88 Keypad RemovalConnecting the MRC88 CONTROLLER/AMPLIFIER Audio ConnectionsBASIC/ADVANCED Video ConnectionsCSM1 Threshold Adjustments AdvancedZone Related Wiring Connections BASIC/ADVANCED/EXPANDEDModulated Video BASIC/ADVANCED/EXPANDED Composite VideoStatus Control Out CO1 and CO2 Zones 7Zone IR BASIC/ADVANCED/EXPANDED Connections AT the Zone Location BASIC/ADVANCED/EXPANDEDSingle Keypad CAT5 Connections Multiple Keypad ConnectionsZone Expansion Connecting TWO MRC88 Controllers Expanded OFFLinking TWO MRC88 CONTROLLER/AMPLIFIER Units MRC88 Connecting Block located on rear of Keypad MRC88 Keypad CAT5 Cable LengthsBASIC/ADVANCED/EXPANDED SETTING-UP the MRC88 System Typical MRC88 SystemPre-Programming the MRC88 Planning the System Basic Mode Advanced Mode Expanded ModeBASIC/ADVANCED/EXPANDED Computer Requirements Minimum Connecting the MRC88 CONTROLLER/AMPLIFIER to the PC Software InstallationIncluded Hardware & Software Items Starting MRC88 Dragon DROP-IR SoftwareStarting a Project Learning IR Commands Creating Palette Files BUILT-IN IR Code Library BASIC/ADVANCED/EXPANDEDBuilt-In Mfg’s IR Command Library Learning IR Commands BASIC/ADVANCED/EXPANDEDRecording Toggle Command Functions To Add a New Function To Rename an Existing FunctionCreating a Palette File BASIC/ADVANCED/EXPANDED Editing BRAND, COMPONENT, and Function Lists Getting Source Commands from the InternetImporting CCF Files Importing Discrete IR Hex Codes Entering RS232 Command Strings ADVANCED/EXPANDEDUsing MRC88 Test Using PC TestRS232 Palette Editor Window Creating AN RS232 Palette File ADVANCED/EXPANDED Creating an RS232 Palette FileConfiguring Source Icons on MRC88 Keypad LCD Programming The ControllerSelecting Icons from the Icon Generator Creating NEW IconsDownloading Source Icons to the Keypad Placing Commands Onto the Virtual Keypad Selecting RS232 Command Palettes ADVANCED/EXPANDEDSelecting Internal Amplifier Commands ADVANCED/EXPANDED Placing Commands on the Virtual Keypad BasicProgramming Sequences Macros Button Edit Pop-Up Menu Editing Buttons on the Virtual KeypadEditing Commands in the Macro Command List Window Editing Commands Zone 1 thruProgramming Power Management and Sense Trigger Codes Programming Power ManagementBasic Power Management Programming Sense Trigger Codes ADVANCED/EXPANDED Programming Sense TriggersTesting Commands Under Power Management and Sense Triggers Zone Options Configuration Default settings set in Basic Mode are as followsName of Zone ADVANCED/EXPANDED RC68 Code GroupPRE AMP Volume Adjust Settings ADVANCED/EXPANDED IR Loop Back Settings ADVANCED/EXPANDEDConfiguring Commands for IR in Zone Transferring the ProjectController Options Programming Zone Audio InputMode of Operation IR RoutingBACK-LIGHT Control Expanded OptionsRS232 Settings Monitor Lockout Mode Factory default DisabledMonitor Lockout Mode Zone Linking Programming Dynamic Zone Link Mode Factory default Disabled RS232 Input Translator Link ALL DynamicLink ALL Static Clear ALLProgramming IR Commands and Sequences IRS232 Input TranslatorRC68 IR Command Macro Window RC68+ IR Code Triggered SequencerProgramming Internal Amplifier Commands Internal Amplifier Command WindowUsing Internal Amplifier Commands Zone Expansion Connecting Multiple MRC88 Controllers Internal Amplifier CommandsProgramming in Expanded Mode Enabling Expanded ModePhysical Connections in Expanded Mode RS232 Control While in Expanded ModeSources 1 through Transferring a Project to the MRC88 Uploading MRC88 ProjectsSaving and BACKING-UP Files Firmware Upgrade Optionis Warm Firmware UpgradeCold Firmware Upgrade Downloading Firmware Files from the WEBTweaking the System Teaching a HAND-HELD Remote to Operate the MRC88 SystemMaking Fine Adjustments Trimming Source Audio Input LevelsZone Adjustments Keypad AdjustmentsPowering the Zone on and OFF Setting the VolumeAccessing Tier 2 Commands Source Slection and ControlZone Settings Audio Adjustments BASIC/ADVANCED/EXPANDEDSystem Status BASIC/ADVANCED Dynamic Monitor Lockout Parental Control ADVANCED/EXPANDEDExpanded RS232 Control ?5SS+ 7PR1+?5SS3+ Commands AO+Queries Volume Level 39 Steps Keypad Button ID MRC88 Setting Level in dB+14 +12Left Speaker Right Speaker MRC88 Setting Attenuation Balance LevelTroubleshooting Problem Probable Cause and SolutionModel MRC88Page 96Model MRC88 RS232 and Expansion PIN OUT Information GND Specifications CertificationsVideo IR SensorModel MRC88 Model MRC88 Xantech Corporation Xantech Corporation Bradley Avenue, Sylmar CA Phone 818.362.0353 fax
Related manuals
Manual 102 pages 31.66 Kb Manual 12 pages 21.17 Kb