Xantech mrc88 installation instructions PRE AMP Volume Adjust Settings ADVANCED/EXPANDED

Page 61

Model MRC88

Page: 61

(BASIC)

In basic mode, the code group can only be set for the entire system. To change the Code Group, click on the drop-down menu in the “SYSTEM CODE GROUP” box and select one of the displayed Code Group choices.

(ADVANCED/EXPANDED)

Each zone of the MRC88 can be set to it’s own individual Code Group. This may be useful when the system requirements so dictate. (i.e. The system requirement calls for having zone-specific remote controls). Since other Xantech IR controlled models are assigned and preset at the factory to different Code Groups, special care should be taken when changing code groups to avoid accidentally changing another products code group number or having the wrong product respond to an IR code intended for a different model.

1.Click the ‘OPTIONS’ button in the bottom of the Virtual Keypad window.

2.In the SELECT ZONE box, click on the zone to be edited

3.In the RC68 GROUP CODE box, click on the drop-down menu and select one of the displayed Code Group choices.

4.Repeat for all zones

PRE AMP VOLUME ADJUST SETTINGS (ADVANCED/EXPANDED)

This feature allows the PreAmp output for the associated zone to be Variable and follow the Volume setting for the entire Zone (track 1:1 with default MRC88 Volume controls on Keypad or RC68 commands via remote) or to be a Fixed output level to be controlled outside of the system. This may be desirable for individual Sub-Zone control. Default for this setting is VARIABLE.

IR LOOP BACK SETTINGS (ADVANCED/EXPANDED)

This feature enables/disables the In-Zone Emitter output located on the rear of each zones Keypad. When enabled, IR codes received via the Keypads IR Sensor and IR generated from any Keypad routed to the Zone, will be sent to this output. This feature can be used to control local (in zone) A/V components such as TV, DVD player, or in-room lighting/thermostat control located in the same location as the keypad. Default for this setting is DISABLE.

1.Click the ‘OPTIONS’ button in the bottom of the Virtual Keypad window.

2.In the SELECT ZONE box, click on the zone to be edited

3.In the IR Loop-Back Settings box, select Loop-Back ENABLE or DISABLE.

4.Repeat for all zones

NOTE: For any IR commands generated from a Keypad intended to be Looped Back to the Zone or to be output the Zone IR, you must first select the zone to be looped back to by right-clicking on the command in the Macro Command List and selecting the appropriate zone under Ir In Zone. Usually you will want this set to CURRENT ZONE. See Figure-32below.

© 2003 Xantech Corporation

Image 61
Contents Installation Instructions Not Expose this Appliance to Rain or Moisture Safety Instructions Read Before Operating EquipmentTable of Contents Programming the Controller ADVANCED/EXPANDED Programming Section Model MRC88 Xantech Corporation MRC88 system includes the following components General InformationModel MRC88 System Overview System Block DiagramCONTROLLER/AMPLIFIER Features Keypad Features MRC88 Front Panel Features and Connections MRC88 CONTROLLER/AMPLIFIER Panel and Feature DescriptionsSystem Status Power-Up Mode Front PanelZone Status Active-Operational Mode Source Component Input Connections MRC88 Rear Panel Features and ConnectionsSource Loop-Thru Connections MRC88 Keypad Front Features MRC88 Keypad Feature DescriptionsMRC88 Keypad Model MRC88 MRC88 Keypad Rear Features and Connections Model MRC88 Keypad Rear Panel Features and FunctionsOperation OUT-OF-THE-BOX PRE Test BASIC/ADVANCED/EXPANDED InstallationKeep perforations on top cover free MRC88Obstructions Expanded Mounting and Installing the MRC88 KeypadMRC88 Keypad mounting template MRC88 Keypad Removal Optional Keypad Back-Box for pre-install applicationsAudio Connections Connecting the MRC88 CONTROLLER/AMPLIFIERBASIC/ADVANCED Video ConnectionsAdvanced CSM1 Threshold AdjustmentsBASIC/ADVANCED/EXPANDED Zone Related Wiring ConnectionsModulated Video BASIC/ADVANCED/EXPANDED Composite VideoStatus CO1 and CO2 Zones 7 Control OutZone IR BASIC/ADVANCED/EXPANDED Connections AT the Zone Location BASIC/ADVANCED/EXPANDEDMultiple Keypad Connections Single Keypad CAT5 ConnectionsOFF Zone Expansion Connecting TWO MRC88 Controllers ExpandedLinking TWO MRC88 CONTROLLER/AMPLIFIER Units MRC88 Keypad CAT5 Cable Lengths MRC88 Connecting Block located on rear of KeypadBASIC/ADVANCED/EXPANDED Typical MRC88 System SETTING-UP the MRC88 SystemPre-Programming the MRC88 Planning the System Basic Mode Advanced Mode Expanded ModeBASIC/ADVANCED/EXPANDED Computer Requirements Minimum Software Installation Connecting the MRC88 CONTROLLER/AMPLIFIER to the PCIncluded Hardware & Software Items Starting MRC88 Dragon DROP-IR SoftwareStarting a Project BUILT-IN IR Code Library BASIC/ADVANCED/EXPANDED Learning IR Commands Creating Palette FilesLearning IR Commands BASIC/ADVANCED/EXPANDED Built-In Mfg’s IR Command LibraryRecording Toggle Command Functions To Add a New Function To Rename an Existing FunctionCreating a Palette File BASIC/ADVANCED/EXPANDED Editing BRAND, COMPONENT, and Function Lists Getting Source Commands from the InternetImporting CCF Files Importing Discrete IR Hex Codes ADVANCED/EXPANDED Entering RS232 Command StringsUsing MRC88 Test Using PC TestRS232 Palette Editor Window Creating an RS232 Palette File Creating AN RS232 Palette File ADVANCED/EXPANDEDProgramming The Controller Configuring Source Icons on MRC88 Keypad LCDSelecting Icons from the Icon Generator Creating NEW IconsDownloading Source Icons to the Keypad Selecting RS232 Command Palettes ADVANCED/EXPANDED Placing Commands Onto the Virtual KeypadSelecting Internal Amplifier Commands ADVANCED/EXPANDED Placing Commands on the Virtual Keypad BasicProgramming Sequences Macros Editing Buttons on the Virtual Keypad Button Edit Pop-Up MenuEditing Commands in the Macro Command List Window Zone 1 thru Editing CommandsProgramming Power Management Programming Power Management and Sense Trigger CodesBasic Power Management Programming Sense Triggers Programming Sense Trigger Codes ADVANCED/EXPANDEDTesting Commands Under Power Management and Sense Triggers Default settings set in Basic Mode are as follows Zone Options ConfigurationName of Zone ADVANCED/EXPANDED RC68 Code GroupIR Loop Back Settings ADVANCED/EXPANDED PRE AMP Volume Adjust Settings ADVANCED/EXPANDEDTransferring the Project Configuring Commands for IR in ZoneZone Audio Input Controller Options ProgrammingIR Routing Mode of OperationBACK-LIGHT Control Expanded OptionsMonitor Lockout Mode Factory default Disabled RS232 SettingsMonitor Lockout Mode Zone Linking Programming Dynamic Zone Link Mode Factory default Disabled Link ALL Dynamic RS232 Input TranslatorLink ALL Static Clear ALLIRS232 Input Translator Programming IR Commands and SequencesRC68+ IR Code Triggered Sequencer RC68 IR Command Macro WindowInternal Amplifier Command Window Programming Internal Amplifier CommandsUsing Internal Amplifier Commands Internal Amplifier Commands Zone Expansion Connecting Multiple MRC88 ControllersEnabling Expanded Mode Programming in Expanded ModePhysical Connections in Expanded Mode RS232 Control While in Expanded ModeSources 1 through Uploading MRC88 Projects Transferring a Project to the MRC88Saving and BACKING-UP Files Warm Firmware Upgrade Firmware Upgrade OptionisCold Firmware Upgrade Downloading Firmware Files from the WEBTeaching a HAND-HELD Remote to Operate the MRC88 System Tweaking the SystemTrimming Source Audio Input Levels Making Fine AdjustmentsKeypad Adjustments Zone AdjustmentsSetting the Volume Powering the Zone on and OFFAccessing Tier 2 Commands Source Slection and ControlAudio Adjustments BASIC/ADVANCED/EXPANDED Zone SettingsSystem Status BASIC/ADVANCED Dynamic Monitor Lockout Parental Control ADVANCED/EXPANDEDExpanded RS232 Control ?5SS+ 7PR1+?5SS3+ AO+ CommandsQueries Volume Level 39 Steps Keypad Button ID Level in dB MRC88 Setting+14 +12Balance Level Left Speaker Right Speaker MRC88 Setting AttenuationProblem Probable Cause and Solution TroubleshootingModel MRC88Page 96Model MRC88 RS232 and Expansion PIN OUT Information GND Certifications SpecificationsVideo IR SensorModel MRC88 Model MRC88 Xantech Corporation Bradley Avenue, Sylmar CA Phone 818.362.0353 fax Xantech Corporation