Frymaster BIH14, MH14 warranty Fryer Troubleshooting

Page 24

Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof container and cleaned daily.

Verify that all O-rings and seals (including those on the Power Shower and on quick-disconnect fittings) are present and in good condition. Replace o-rings and seals if worn or damaged.

Check filtration system integrity as follows:

With the filter pan empty, place each oil return handle, one at a time, in the ON position. Verify that the pump activates and that bubbles appear in the cooking oil/shortening (or that gurgling is heard from the Power Shower port) of the associated frypot.

Close all oil return valves (i.e., place all oil return handles in the OFF position). Verify proper functioning of each oil return valve by activating the filter pump using the lever on one of the oil return handle microswitches. No air bubbles should be visible in any frypot (or no gurgling should be heard from the Power Shower ports).

Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to 350°F (177°C) into the filter pan and close the frypot drain valve. Place the oil return handle in the ON position. Allow all cooking oil/shortening to return to the frypot (indicated by bubbles in the cooking oil/shortening or, on units with Power Showers, cessation of oil flow from the Power Shower). Return the oil return handle to the OFF position. The frypot should have refilled in no more than 2 minutes and 30 seconds.

5.2 Fryer Troubleshooting

Below are simple checks that should be performed before contacting the FASC:

Is the ON/OFF switch in the ON position?

Is the drain valve completely closed?

Is the face of the fryer’s power plug flush with the outlet plate (i.e., no part of the prongs visible)?

Is the circuit breaker set in the ON position and are fuses OK?

Is the computer display blank? Check the hood cord (small cord), ensuring it is pushed fully into the socket. Also check the ANSUL/hood system.

Does the display show ignition failure? If so, turn off the fryer, open the drain valve slightly then close it. Attempt to operate the fryer.

Does the fryer remain below setpoint temperature? If so, verify that the face of the plug is flush with the outlet plate (i.e., no part of the prongs visible). Also check the circuit breaker.

Does the computer display on a split-vat unit show ignition failure? If so, turn off both vats. Turn on the one that displayed ignition failure first, then turn on the other vat.

5-2

Image 24
Contents OPERATOR’S Manual Frymaster BIH/MH14 Series Electric Fryer Computers FCC Warranty Statement Parts Return Safety Information IntroductionGeneral Shipping Damage Claim Procedure Computer InformationService Information Installation Instructions Do not block the area around the base or under the fryersPower Requirements After Fryers Are Under The Fry Station HoodFrypot Boil-Out Equipment Setup and Shutdown Procedures Operating Fryers With Analog ControllersIntroduction to the Analog Controller Description Analog Controller Operating Instructions Operating the BUILT-IN Filtration System BIH14 Series only Description FunctionSTEP-BY-STEP Filtration Instructions Incorrect Correct With fryer off, open drain valve Page Page Care and Cleaning of Your Fryer and Filter System Page Water in the Filter PAN Preventive Maintenance and Troubleshooting Preventive MaintenanceFryer Troubleshooting Troubleshooting Built-in Filtration Systems BIH Series Only Always filter with the cooking To properly filter, the oil or shortening