Frymaster MH14, BIH14 warranty To properly filter, the oil or shortening

Page 27

Pump starts, but no transfer takes place or the transfer is very slow.

 

A. To properly filter, the oil or shortening

 

should be at or near 350°F (177°C).

 

At temperatures lower than this, the

 

oil/shortening becomes too thick to

A. Cooking oil/shortening is too cold for

pass through the filter medium easily,

resulting in much slower oil return

filtering.

and eventual overheating of the filter

 

 

pump motor. Ensure that the

 

cooking oil/shortening is at or near

 

frying temperature before draining

 

into filter pan.

B. Improperly installed or prepared filter

 

pan components.

B. Remove the oil from the filter pan

 

Test: Close the drain valve. Move

and replace the filter paper, ensuring

the filter handle to the OFF position,

that the filter screen is in place under

pull the filter pan (and Power

the paper.

Shower, if so equipped) from the

If this does not correct the problem,

unit. Move the filter handle to the ON

position.

the filter tube suction tube is probably

If a strong stream of air is being

blocked. Remove the blockage using

a thin, flexible wire. If unable to

pumped out of the oil return port (or

remove the blockage, call FASC.

the Power Shower port), the problem

 

is with the filter pan components.

 

C. Improperly installed or prepared filter

 

pan components.

C. Verify that filter connection o-rings

 

Test: Close the drain valve. Move

are present and in good condition.

 

the filter handle to the OFF position,

Replace the filter paper, ensuring

and pull the filter pan (and Power

that the filter screen is properly

Shower, if so equipped) from the

positioned under the paper.

unit. Move the filter handle to the ON

 

position.

If using Magnasol filter assembly,

 

If a strong stream of air is being

verify that o-ring is present and in

good condition on filter screen fitting.

pumped out of the oil return port (or

 

the Power Shower port), the problem

 

is with the filter pan components.

 

 

 

5-5

Image 27
Contents OPERATOR’S Manual Frymaster BIH/MH14 Series Electric Fryer Computers FCC Warranty Statement Parts Return Safety Information IntroductionGeneral Computer Information Shipping Damage Claim ProcedureService Information Do not block the area around the base or under the fryers Installation InstructionsAfter Fryers Are Under The Fry Station Hood Power RequirementsFrypot Boil-Out Equipment Setup and Shutdown Procedures Operating Fryers With Analog ControllersIntroduction to the Analog Controller Description Analog Controller Operating Instructions Description Function Operating the BUILT-IN Filtration System BIH14 Series onlySTEP-BY-STEP Filtration Instructions Incorrect Correct With fryer off, open drain valve Page Page Care and Cleaning of Your Fryer and Filter System Page Water in the Filter PAN Preventive Maintenance Preventive Maintenance and TroubleshootingFryer Troubleshooting Troubleshooting Built-in Filtration Systems BIH Series Only Always filter with the cooking To properly filter, the oil or shortening