Priority Lockout Mode (Factory default: “DISABLED”)

This mode is the opposite of “Whole House”. That is, when one is ENABLED, the other is DISABLED. When ENABLED, if Zone 1 selects a source, Zone 1 will maintain exclusive control over that source until Zone 1 either selects another source or is turned OFF. Zones 2-4 can monitor the source, but cannot control that source until released by Zone 1. Once Zone 1 has released the source, if the source is re-selected by one of Zones 2-4, that zone will take control and will then also have priority.

IR Routing (Factory default: “ENABLED”)

This mode allows selective control of multiple same-brand same-model components such as multiple DVD players or Satellite receivers. When “ROUTING ENABLE” is selected, IR commands are directed only to the specific emitter output for the source selected in a zone, and not to the other source emitter outputs. When “ROUTING DISABLE” is selected, IR commands are directed to all emitter outputs. The COMMON emitter output will always output all IR commands.

Backlight Control (Factory default: 6 seconds)

This setting adjusts the duration that the Keypad LCD and Buttons will remain lit after a keypad button press. Backlighting is variable from ‘always off’ to ‘always on’ or set to time out after 1 to 10 seconds in one second increments. This setting will set the backlighting for ALL keypads in the system. IR codes generated by remote controls do not activate backlighting.

1.Click “ALWAYS ON” to backlight a zone’s keypad(s) for as long as the zone is ON. Backlight turns off when the zone is turned OFF. Useful in dark rooms.

2.Click “ALWAYS OFF” keypad(s) backlight will never turn on. Useful in rooms that are always brightly lit.

3.Click “TIMED” and use ‘Timed Backlight Control’ Pulldown Menu to set backlight duration from 1-10 seconds.

Monitor Lockout Mode (Factory default: “DISABLED”)

This mode can only be used if ‘Priority Lockout’ is selected. Checking the corresponding boxes prevents sources from being monitored or controlled in specific zones. Example: If adult content is not to go to the children’s areas this can be set at the time of system installation.

1.Select “PRIORITY LOCKOUT MODE” The Monitor Lockout boxes will be activated.

2.By Zone, click in the box of any Source that is not to be monitored in that zone.

Dynamic Monitor Lockout (Factory default: “DISABLED”)

This mode allows monitor lockout ‘on the fly’. There may be times when a source is generating program material that can be made available to all zones/users. At other times this same source may be putting out material that is not suitable for some zones/users. When the “ADMINISTRATOR” box is checked for a given zone, for example, Zone 1, a special keypad command can block the audio and video for a given source from being monitored by Zones 2-4 (Zones 2-8 in Expanded mode). When the special keypad command is issued a second time, in Zone 1, that source is released and can then be selected and monitored by Zones 2-4 (Zones 2-8 in Expanded mode). That source remains under ‘priority control’ of Zone 1, until Zone 1 selects another source or turns OFF.

1.Select “PRIORITY LOCKOUT MODE” The Monitor Lockout boxes will be activated.

2.Click the “ADMINISTRATOR” box for any zone that is to have ‘Dynamic Monitor Lockout’ ability.

3.After the project has been transferred to the MRC44 Controller, on a keypad in a zone with ‘Administrator’ control, simultaneously press the ”STATUS” and “SOURCE” buttons for the device to be ‘locked out’. If any zone has that same source selected, the audio will mute and the video will go blank. A message: “Monitor Locked” will appear on the keypad(s) in those zones.

4.To unlock, from the same zone with ‘Administrator’ control, simultaneously press ”STATUS” and “SOURCE” again. If any zone has that same source selected, the message “Monitor Unlocked” will appear, however, video and audio will not be routed to that zone until a source select button is pressed. A message: “Monitor Unlocked” will appear on the keypad(s) in those zones. The ‘Administrator’ zone will retain priority until that zone selects another source or turns OFF.

IR Output Intensity Settings

Emitter outputs 3, 4 and common have adjustable output levels to compensate for the varying IR sensitivities in different branded products. The Low setting is equivalent to the emitter out on a 789-44 Connecting block (470

© 2002 Xantech Corporation

Image 35
Contents Installation Instructions Not Expose this Appliance to Rain or Moisture Safety Instructions Read Before Operating EquipmentTable of Contents General Information System Overview System Block DiagramKeypad Features CONTROLLER/AMPLIFIER FeaturesZone Status Operational Mode MRC44 CONTROLLER/AMPLIFIER Panel and Feature DescriptionsSystem Status Power-Up Mode 8Model MRC44 Source Component ConnectionsModel MRC44 Model MRC44 Keypad Front Panel Features and Functions MRC44 Keypad Feature DescriptionsModel MRC44 Keypad Rear Panel Features and Functions Operation OUT-OF-THE-BOX BASIC/ADVANCED/EXPANDED Expanded InstallationMRC44 Keypad mounting template Cutting the holeMRC44 Keypad Removal Installing the Mounting BracketBASIC/ADVANCED Connecting the MRC44 CONTROLLER/AMPLIFIERSpeaker Connections Zone Wiring Connections at the MRC44 Controller/AmplifierBASIC/ADVANCED/EXPANDED Control Out Video Connections BASIC/ADVANCED/EXPANDED Composite VideoModulated Video Control Out and Status Connections StatusOFF Connections AT the Zone Location BASIC/ADVANCED/EXPANDEDMRC44 Keypad CAT5 Cable Lengths Extended Runs and Secondary Keypad In ZoneFor setup of an expanded system, see Figure SETTING-UP the MRC44 SystemZone Included Hardware & Software Items Programming the MRC44 System Using the DRAG450MRC SoftwareSoftware Installation Planning the SystemSerial Port Selection Learning IR CommandsToggle Command Function Starting MRC44 Dragon Drop-IRAdding Components and Functions Editing and Testing IR CommandsCreating Palettes Adding BrandsProgramming Keypads Basic Putting Codes to Work in the MRC44Advanced DRAG450MRC Basic System WindowMRC44 Keypad LCD Icon Generator ADVANCED/EXPANDED Placing Commands On The Virtual Keypad BasicCreating New Icons Selecting PalettesEditing Sequences Timed DelaysRepeat Commands Push & Hold Tiered CommandsSystem SET-UP Procedures Programming the MRC44 CONTROLLER/AMPLIFIER Video Sensing Sense Trigger Programming Power Management and Sense Trigger Codes BasicVideo Sensing Power Management Current Sensing Power Management Sense InputsTransferring The Project Basic Current Sense De-Bounce SettingsADVANCED/EXPANDED Programming Polarity of Sense InputIR Output Intensity Settings Zone Linking Expanded OptionsFirmware Upgrade Options RC68+ IR Code Triggered Sequencer Internal Amplifier Command Window Programming Internal Amplifier CommandsCommand Name Command List Name Parameter Internal Amplifier CommandsAutomatic Save Transferring a Project to the MRC44 BASIC/ADVANCEDUploading MRC44 Projects Saving and BACKING-UP FilesBacking-Up Project Files Using Backup FilesFine Tuning Adjusting Input Level TrimLCD Backlight Adjustment Zone AdjustmentsIR Sensitivity Adjustment System Status Audio AdjustmentsOperating Instructions Zone ControlDynamic Zone Link Advanced Combining IR Outputs Zone Expansion Using Multiple MRC44 ControllersSource A/V Distribution and Power Management AV61 ConnectionsExpanded System Diagram Problem Probable Cause and Solution TroubleshootingModel MRC44Page 50Model MRC44 Problem Probable Cause and Solution Xantech Corporation SpecificationsCertifications