Page: 46 | Model MRC44 |
ZONE EXPANSION USING MULTIPLE MRC44 CONTROLLERS
Two MRC44 Controllers can be used to expand the number of zones in a MRC44 system to eight. When doing so there are additional Xantech components that will have to be added to the system.
1.AV61 Audio/Video Six Way Distribution Amplifier. This device allows the single A/V outputs of source components to be properly split to the inputs of both MRC44 Controllers. System requirement: 1 per source.
2.
Source A/V Distribution and Power Management
The Application Diagram, Figure 24, shows two MRC44 Controllers being used in a
AV61 Connections
1.Connect the A/V output of source 1 to the A/V input on the AV61. Connect output 1 on the AV61 to input 1 on the Primary MRC44 Controller.
2.Connect output 2 on the AV61 to input 1 on the Secondary MRC44 Controller.
3.Repeat for all sources.
Combining IR Outputs
Application Diagram, Figure 24, also shows multiple
793-10 Connections
1.Using a mono mini to mini plug cable, [Xantech P/N 6015900 (5’ cable) P/N 6017450 (10’ cable)] connect IR out 1 from the Primary MRC Controller to input 1 on the
2.Using a mono mini to mini plug cable, connect IR out 1 from the Secondary MRC Controller to input 2 on the
3.Plug the emitter for source 1 into control output A on the
4.Attach the emitter to the IR eye on component to be controlled.
5.Repeat for as many sources used.
IMPORTANT NOTE: Internal Amplifier Commands cannot be communicated from Controller to Controller. These commands can be used for zones running through a single Controller.
© 2002 Xantech Corporation