HUMIDITY
Address - – serial number of the sensor.
DeviceType - Device type. (DeviceType=HUMIDITY)
PollTime - How often to poll the device. (ms)
Label - Name used for the device (and Topic).
Log - Enable/disable logging of device.
LogDecimalPlaces - Number of decimals to create when logging. PollSamples - No. of samples per poll (must be odd no.) If >0 Median Filter
if <0 then Average Filter is used.
Temperature - Indicates if sensor needs temperature compensation. (0 or 1).
DwellTime - Time allowed to charge the probe. (ms) PostDwell - Time after reading to allow bus to recover. (ms) OverSampleDwell - Time before each over sample to charge probe. (ms) DeadBand - Dead band filtering value in % of full scale.
Description - General purpose description.
Cal1Raw - Two point calibration point 1.
Cal2Raw - Two point calibration point 2.
Cal1Engr - Two point calibration engineering units for point 1.
Cal2Engr - Two point calibration engineering units for point 2.
Units - % Relative Humidity
TempCoeff - PPM temperature coefficient of the sensor. TempCalib - Temperature at which the calibration was done. TempAddress – serial number of the temperature sensor in the probe. MacroFilterElements - running macro filter of the sampled data. Syntax:
[no. of elements, type] where no. of elements is number of samples to filter; type – “AVERAGE”, “MEDIAN” and “AVERAGEMEDIAN”. Default is “=3,MEDIAN”. Example: FilterElements1=6,AVERAGE CorrID – What CorrectionID to use with this device. Must be found in the
"Correction.INI" file that you write and keep in the same directory as the