Omega Engineering M-4066 manual Wireless Analog Output, OUTPUTANALOG1

Page 31

Wireless Analog Output

(OMWT-ANGOUT) [Devicen] - Section name.

Address - serial number of the sensor.

NodalAddress – node where the output will be sent. Defaults to 0 for the OMWT-REC323-600 Receiver. For OMWT-RECIP, the node number represents each receiver starting at 1. If set to 0, OMWT-SOFT-OPC will send the output packet to all nodes.

DeviceType - Device type. (DeviceType= OUTPUTANALOG)

PollTime - How often to poll the device or wait for packet. (ms) Defaults to 0 for outputs.

Label - Name used for the device (and Topic) (typically

OUTPUTANALOG1).

Log - Enable/disable logging of device.

LogDecimalPlaces - Number of decimals to create when logging. Description - General purpose description.

Cal1Raw - Two point calibration point 1 (default 0).

Cal2Raw - Two point calibration point 2 (default 4095).

Cal1Engr - Two point calibration engineering units for point 1 (default 0). Cal2Engr - Two point calibration engineering units for point 2 (default

100).

Units - units label (default "%").

Description - Generic description field

OutTries – number of times to send the output packet. (default 10) OutInterval – (in milliseconds) – the interval of time between sending

output packets. (default 1000).

OMWT-SOFT-OPC Server

OMWT-SOFT-OPC Server .ini File Format N 27

Image 31
Contents OWMT-SOFT-OPC OMEGAnet Online Service Internet e-mail Info@omega.com Contents OMWT-SOFT-OPC Server Data Logging Quick Start OverviewOverview OMWT-SOFT-OPC Server Wireless Setup OMWT-SOFT-OPC Server and WirelessDescription Edit Device OMWT-REPEAT ReceiversDevice List OMWT-RECIPIdentification Filtering PollingDiagnostics What is OPC? Data LoggingChange Port SetupOMWT-SOFT-OPC Main Window Main WindowAdd/Delete IP Connection View IP Connection Status New and Edit OutputsTrain Search and Add Devices ReConfigure NetQuit Devices ErrorsHelp OMWT-SOFT-OPC.ini OMWT-SOFT-OPC Server .INI File FormatServer IP Addresses LoggingTemperature Setup Humidity Directcnt Digcounter and Directional CounterCnttemp FASTCNTTEMP1 FastcnttempAlarmtemp OMWT-AIN5V, OMWT-AIN10V, OMWT-AIN20MA, OMWT-VIB, Omwt Analog InputMOT Access/Control Reader Dual Discrete Output RepeaterOUTPUTANALOG1 Wireless Analog OutputOMWT-SOFT-OPC INI Backup Device Names OMWT-SOFT-OPC Server TagsOMWT-SOFT-OPC Server Tags Device Tag Names TemperatureDigital I/O DIGITALn Temperature/Humidity HUMIDITYn OMWT-IRCNT, OWT-DIRCNT Cnttemp CNTTEMPn Fastcnttemp FASTCNTTEMPn Alarmtemp ALARMTEMPn AnalogInput AIn Access/Control Reader IDRn OMWT-SOFT-OPC Server Tags Repeater REPEATERn Dual Discrete Output OUTPUTDISCn Wireless Analog Output OutputAnalogn Server Item Names OMWT-SOFT-OPC Server OMWT-SOFT-OPC Server Tags N OMWT-SOFT-OPC Server Tags OMWT-SOFT-OPC Server Data Logging FeaturesFile Management File Format Data Log File Format Error Log OMWT-RECIP Receivers Setting up to use OMWT-RECIP ReceiversOverview of OMWT-RECIP Receivers OMWT-RECIP Receiver Notes Communication Errors Error MessagesCommunication Error CRC16 or Time Out Runtime ErrorsOMWT-SOFT-OPC Server Internal Error Pre-defined Thermistor Why Use CorrectionsCorrections Correction IDsCorrection.INI file How to use CorrectionsNtcnormalres Predefined CorrectionsWARRANTY/DISCLAIMER OMEGA…Of Course

M-4066 specifications

Omega Engineering, a renowned name in measurement and control solutions, has developed a range of high-quality devices to meet the diverse needs of industries worldwide. Among these products, the Omega M-4066 stands out as a versatile and highly functional instrument designed for precise measurement and control applications.

The Omega M-4066 is a state-of-the-art digital thermometer, ideally suited for various industrial applications, including laboratory settings and process control environments. With its robust construction and user-friendly interface, this device is designed to facilitate accurate temperature readings in real-time.

One of the standout features of the M-4066 is its wide temperature measurement range. It can accurately measure temperatures from -200°C to 1372°C, making it suitable for a variety of applications, including cryogenics and high-temperature processes. This versatility allows users to apply it across multiple sectors, including manufacturing, pharmaceuticals, and food processing.

Equipped with advanced thermocouple technology, the M-4066 ensures rapid response times and high accuracy in temperature measurements. Its compatibility with different types of thermocouples, such as Type K, J, T, and E, enhances its versatility, allowing users to select the most appropriate sensors for their specific applications.

The M-4066 also features a large, easy-to-read LCD display that provides clear and precise temperature readouts. A range of additional functionalities, including maximum and minimum temperature readings, allows users to monitor fluctuations and maintain the desired environmental conditions effectively.

In terms of connectivity, the device offers options for data logging and communication with external systems. Users can interface the M-4066 with computers or control systems, enabling them to analyze data trends and implement necessary adjustments in real time.

The Omega M-4066 is built with durability in mind, featuring an IP65-rated enclosure that protects against dust and water ingress. This resilience is particularly beneficial for use in harsh industrial environments, ensuring longevity and reliable performance.

In summary, the Omega M-4066 is a powerful, flexible, and reliable digital thermometer that provides accurate temperature measurement across a broad range of applications. With its advanced features, diverse connectivity options, and robust design, it is an essential tool for professionals looking to enhance their measurement and control capabilities.