Omega Engineering M-4066 manual Error Messages, Communication Errors

Page 57

Error Messages

Communication Errors

OMWT-SOFT-OPC Server communication initialization errors will cause the 'OMWT-SOFT-OPC Initializing Error!" window to be displayed to help you determine what the cause of failure may be and to allow you to retry or abort the program.

Error In Finding/Initializing Port.

You have specified a port that does not exist on your computer. Use Setup to change to a port you have, or select Auto and let OMWT-SOFT-OPC Server search for you.

Cannot Open Communication Port; Already In Use.

Close application that is using the communication port or provide OMWT-SOFT-

OPC Server with another RS-232 communications port.

Cannot Find Receiver!

This indicates OMWT-SOFT-OPC Server cannot find the receiver. If the receiver is connected with a serial cable, try another serial cable. The receiver uses the REC232 handshake lines for power. Is the power LED on?

Try another port.

Cannot find and load lowlevel driver!

OMWT-SOFT-OPC Server cannot find one of its DLL drivers. Either the driver is missing from the Windows\System folder or the registry entry got erased. Try reinstalling the program. If problem continues, please consult your dealer.

OMWT-SOFT-OPC Server

Error Messages N 53

Image 57
Contents OWMT-SOFT-OPC OMEGAnet Online Service Internet e-mail Info@omega.com Contents OMWT-SOFT-OPC Server Data Logging Quick Start OverviewOverview OMWT-SOFT-OPC Server OMWT-SOFT-OPC Server and Wireless Wireless SetupDescription Edit Device Device List ReceiversOMWT-RECIP OMWT-REPEATIdentification Filtering PollingDiagnostics What is OPC? Data LoggingOMWT-SOFT-OPC Main Window SetupMain Window Change PortAdd/Delete IP Connection View IP Connection Status New and Edit OutputsTrain Search and Add Devices ReConfigure NetDevices Errors QuitHelp OMWT-SOFT-OPC.ini OMWT-SOFT-OPC Server .INI File FormatServer IP Addresses LoggingTemperature Setup Humidity Directcnt Digcounter and Directional CounterCnttemp FASTCNTTEMP1 FastcnttempAlarmtemp Analog Input OMWT-AIN5V, OMWT-AIN10V, OMWT-AIN20MA, OMWT-VIB, OmwtMOT Access/Control Reader Dual Discrete Output RepeaterOUTPUTANALOG1 Wireless Analog OutputOMWT-SOFT-OPC INI Backup Device Names OMWT-SOFT-OPC Server TagsOMWT-SOFT-OPC Server Tags Device Tag Names TemperatureDigital I/O DIGITALn Temperature/Humidity HUMIDITYn OMWT-IRCNT, OWT-DIRCNT Cnttemp CNTTEMPn Fastcnttemp FASTCNTTEMPn Alarmtemp ALARMTEMPn AnalogInput AIn Access/Control Reader IDRn OMWT-SOFT-OPC Server Tags Repeater REPEATERn Dual Discrete Output OUTPUTDISCn Wireless Analog Output OutputAnalogn Server Item Names OMWT-SOFT-OPC Server OMWT-SOFT-OPC Server Tags N OMWT-SOFT-OPC Server Tags OMWT-SOFT-OPC Server Data Logging FeaturesFile Management File Format Data Log File Format Error Log Setting up to use OMWT-RECIP Receivers OMWT-RECIP ReceiversOverview of OMWT-RECIP Receivers OMWT-RECIP Receiver Notes Communication Errors Error MessagesRuntime Errors Communication Error CRC16 or Time OutOMWT-SOFT-OPC Server Internal Error Corrections Why Use CorrectionsCorrection IDs Pre-defined ThermistorCorrection.INI file How to use CorrectionsNtcnormalres Predefined CorrectionsWARRANTY/DISCLAIMER OMEGA…Of Course

M-4066 specifications

Omega Engineering, a renowned name in measurement and control solutions, has developed a range of high-quality devices to meet the diverse needs of industries worldwide. Among these products, the Omega M-4066 stands out as a versatile and highly functional instrument designed for precise measurement and control applications.

The Omega M-4066 is a state-of-the-art digital thermometer, ideally suited for various industrial applications, including laboratory settings and process control environments. With its robust construction and user-friendly interface, this device is designed to facilitate accurate temperature readings in real-time.

One of the standout features of the M-4066 is its wide temperature measurement range. It can accurately measure temperatures from -200°C to 1372°C, making it suitable for a variety of applications, including cryogenics and high-temperature processes. This versatility allows users to apply it across multiple sectors, including manufacturing, pharmaceuticals, and food processing.

Equipped with advanced thermocouple technology, the M-4066 ensures rapid response times and high accuracy in temperature measurements. Its compatibility with different types of thermocouples, such as Type K, J, T, and E, enhances its versatility, allowing users to select the most appropriate sensors for their specific applications.

The M-4066 also features a large, easy-to-read LCD display that provides clear and precise temperature readouts. A range of additional functionalities, including maximum and minimum temperature readings, allows users to monitor fluctuations and maintain the desired environmental conditions effectively.

In terms of connectivity, the device offers options for data logging and communication with external systems. Users can interface the M-4066 with computers or control systems, enabling them to analyze data trends and implement necessary adjustments in real time.

The Omega M-4066 is built with durability in mind, featuring an IP65-rated enclosure that protects against dust and water ingress. This resilience is particularly beneficial for use in harsh industrial environments, ensuring longevity and reliable performance.

In summary, the Omega M-4066 is a powerful, flexible, and reliable digital thermometer that provides accurate temperature measurement across a broad range of applications. With its advanced features, diverse connectivity options, and robust design, it is an essential tool for professionals looking to enhance their measurement and control capabilities.