Frymaster BK1814E operation manual Power Requirements, Three 3 Phase Requirements

Page 12

2.2Power Requirements

Three (3) Phase Requirements

 

MODEL

VOLTAGE

WIRE

 

SERVICE

 

 

 

 

 

RE14/RE1814

208

3

 

RE14/RE1814

240

3

 

RE14/RE1814

480

3

 

RE14/RE1814

220/380

4

 

RE14/RE1814

240/415

4

 

RE14/RE1814

230/400

4

 

RE17/RE1814E

208

3

 

RE17/RE1814E

240

3

 

RE17/RE1814E

480

3

 

RE17/RE1814E

220/380

4

 

RE17/RE1814E

240/415

4

 

RE17/RE1814E

230/400

4

 

RE22/RE1822

208

3

 

RE22/RE1822

240

3

 

RE22/RE1822

480

3

 

RE22/RE1822

220/380

4

 

RE22/RE1822

240/415

4

 

RE22/RE1822

230/400

4

MINIMUM WIRE

AMPS

 

SIZE

 

(per leg)

AWG

 

(mm)

 

 

6

 

(4.11)

39

6

 

(4.11)

34

8

 

(2.59)

17

6

 

(4.11)

21

6

 

(4.11)

20

6

 

(4.11)

21

6

 

(4.11)

48

6

 

(4.11)

41

6

 

(4.11)

21

6

 

(4.11)

26

6

 

(4.11)

24

6

 

(4.11)

25

4

 

(5.19)

61

4

 

(5.19)

53

6

 

(4.11)

27

6

 

(4.11)

34

6

 

(4.11)

31

6

 

(4.11)

32

Single Phase Requirements

MODEL

VOLTAGE

WIRE

SERVICE

 

 

 

RE14/RE1814

208

2

RE14/RE1814

240

2

RE14/RE1814

480

2

MINIMUM WIRE

AMPS

 

SIZE

 

(per leg)

AWG

 

 

(mm)

 

 

 

3

 

 

(5.83)

68

4

 

 

(5.19)

59

8

 

 

(3.26)

30

NOTICE

If this appliance is permanently connected to fixed wiring, it must be connected by means of copper wires having a temperature rating of not less than 167°F (75°C).

DANGER

This appliance must be connected to a power supply having the same voltage and phase as specified on the rating plate located on the inside of the appliance door.

DANGER

All wiring connections for this appliance must be made in accordance with the wiring diagram(s) furnished with the appliance. Refer to the wiring diagram(s) affixed to the inside of the appliance door when installing or servicing this equipment.

2.3Positioning the Fryer

DANGER

No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster Service Hotline at 1-800-551-8633.

2-3

Image 12
Contents Hour Service Hotline Frymaster BK1814E Series Electric FryerCanada Page Tilt Housing BK1814E Series Electric Fryer Table of Contents Operator Troubleshooting Safety Information GeneralController Information European Community CE Specific Information DefinitionsShipping Damage Claim Procedure Service InformationGeneral Clearance and Ventilation Australian RequirementsPower Requirements Three 3 Phase RequirementsPage Equipment Setup and Shutdown Procedures Shutdown ControllersPage Filter Preparation Filter Components Assembling the Filter Return filter pan to cabinet Installing the Filter Filtering Tools Operating the Filter 4.5.1 Filter Operation Filter Operation Overfill the FrypotFilter Pump Reset Switch Draining and Disposing of Waste Oil Page Clean the Frypot and Heating Elements- Weekly Annual/Periodic System InspectionFryer Built-In Filtration System Before calling a service agent or the Frymaster Hotline IntroductionProblem Probable Causes Corrective Action Troubleshooting Controller and Heating ProblemsProblem Probable Causes Error Messages and Display ProblemsFiltration Problems StartUser Replaceable Parts Part Number DescriptionFilter Pan Components This page Intentionally Left Blank Service Hotline