Frymaster BK1814E operation manual Filtration Problems, Start

Page 33

6.2.3 Filtration Problems

Problem

Probable Causes

Corrective Action

 

 

A. Verify that the power cord is

 

A. Power cord is not plugged in or

fully plugged in. If so, verify

 

circuit breaker is tripped.

that circuit breaker is not

 

 

tripped.

 

 

B. If the motor is too hot to touch

 

 

for more than a few seconds, the

 

B. Pump motor has overheated

thermal overload switch has

 

causing the thermal overload

probably tripped. Allow the

Filter pump won't

switch to trip.

motor to cool at least 45

 

minutes then press the Pump

start.

 

 

Reset Switch.

 

 

 

C. Blockage in filter pump.

C. Pump blockages are usually

 

Test: Close the drain valve and

caused by sediment buildup in

 

the pump due to improperly

 

pull the filter pan out from the

sized or installed filter paper

 

fryer. Activate the pump. If the

and failure to use the crumb

 

pump motor hums for a short time

screen. Call a FAS.

 

then stops, the probable cause is

 

 

blockage of the pump itself.

 

Filter pump runs

Blockage in filter pan suction tube.

The blockage may be caused by

Test: Close the drain valve and pull

sediment buildup or, if solid

but oil does not

shortening is used, solidified

return to frypot and

the filter pan out from the fryer.

shortening in the tube. Use a thin,

there is no bubbling

Activate the pump. If bubbling oil

flexible wire to remove the

oil.

occurs, there is a blockage in the

blockage. If the blockage cannot

 

filter pan suction tube.

be removed, call a FAS.

 

 

A. If using filter paper or pad

 

 

configuration, verify that filter

 

 

screen is in bottom of pan with

Filter pump runs,

 

paper or pad on top of screen.

 

 

but oil return is very

A. Improperly installed filter pan

Verify that O-rings are present

slow and bubbling

and in good condition on filter

components.

oil occurs.

pan connection fitting.

 

 

 

If using Magnasol filter

 

 

assembly, verify that O-ring is

 

 

present and in good condition on

 

 

filter screen fitting.

6-4

Image 33
Contents Frymaster BK1814E Series Electric Fryer Hour Service HotlineCanada Page Tilt Housing BK1814E Series Electric Fryer Table of Contents Operator Troubleshooting Safety Information GeneralController Information Definitions European Community CE Specific InformationService Information Shipping Damage Claim ProcedureGeneral Australian Requirements Clearance and VentilationThree 3 Phase Requirements Power RequirementsPage Equipment Setup and Shutdown Procedures Controllers ShutdownPage Filter Preparation Filter Components Assembling the Filter Return filter pan to cabinet Installing the Filter Filtering Tools Operating the Filter 4.5.1 Filter Operation Overfill the Frypot Filter OperationFilter Pump Reset Switch Draining and Disposing of Waste Oil Page Clean the Frypot and Heating Elements- Weekly Annual/Periodic System InspectionFryer Built-In Filtration System Introduction Before calling a service agent or the Frymaster HotlineTroubleshooting Controller and Heating Problems Problem Probable Causes Corrective ActionError Messages and Display Problems Problem Probable CausesStart Filtration ProblemsUser Replaceable Parts Part Number DescriptionFilter Pan Components This page Intentionally Left Blank Service Hotline