Verify that all safety features (i.e. contactor shields, drain safety switches, reset switches, etc.) are present and functioning properly.

Verify that the frypot is in good condition and free of leaks and that the frypot insulation is in serviceable condition.

Verify that all wiring harnesses and connections are tight and in good condition.

Built-In Filtration System

Inspect all oil-return and drain lines for leaks and verify that all connections are tight.

Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof container and cleaned daily.

Verify that all O-rings and seals (including those on the quick-disconnect fittings) are present and in good condition. Replace O-rings and seals if worn or damaged.

Check filtration system integrity as follows:

Verify that filter pan cover is present and properly installed.

With the filter pan empty, place each oil return handle, one at a time, in the ON position. Verify that the pump activates and that bubbles appear in the oil of the associated frypot.

Close all oil return valves (i.e., place all oil return handles in the OFF position). Verify proper functioning of each oil return valve by activating the filter pump using the lever on one of the oil return handle microswitches. No air bubbles should be visible in any frypot.

Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to 350°F (177°C) into the filter pan and close the frypot drain valve. Place the oil return handle in the ON position. Allow all oil to return to the frypot, indicated by bubbles in the oil. Return the oil return handle to the OFF position. The frypot should have refilled in no more than 2 minutes and 30 seconds.

5-3

Image 29
Contents Frymaster BK1814E Series Electric Fryer Hour Service HotlineCanada Page Tilt Housing BK1814E Series Electric Fryer Table of Contents Operator Troubleshooting Controller Information Safety InformationGeneral Definitions European Community CE Specific InformationService Information Shipping Damage Claim ProcedureGeneral Australian Requirements Clearance and VentilationThree 3 Phase Requirements Power RequirementsPage Equipment Setup and Shutdown Procedures Controllers ShutdownPage Filter Preparation Filter Components Assembling the Filter Return filter pan to cabinet Installing the Filter Filtering Tools Operating the Filter 4.5.1 Filter Operation Overfill the Frypot Filter OperationFilter Pump Reset Switch Draining and Disposing of Waste Oil Page Fryer Clean the Frypot and Heating Elements- WeeklyAnnual/Periodic System Inspection Built-In Filtration System Introduction Before calling a service agent or the Frymaster HotlineTroubleshooting Controller and Heating Problems Problem Probable Causes Corrective ActionError Messages and Display Problems Problem Probable CausesStart Filtration ProblemsFilter Pan Components User Replaceable PartsPart Number Description This page Intentionally Left Blank Service Hotline