Frymaster BK1814E operation manual Filter Operation, Overfill the Frypot

Page 24

4.5.1 Filter Operation (cont.)

WARNING

DO NOT hammer on the drain valve with the cleanout rod or other objects. Damage to the ball inside will result in leaks and will void the Frymaster warranty.

5.After all oil has drained from the frypot into the filter pan, turn the yellow handle (right) to open the oil return valve and activate the filter pump. Leave the red handle in the open position.

6.Oil will begin to pump from the filter pan into the frypot. If the frypot sides and bottom have sediment deposits, clean the frypot with the cleaning brush included with the fryer.

7.Allow the oil to circulate for approximately 5 minutes (process known as "polishing") to remove suspended particles.

8.After the filter cycle is complete, close the drain valve (push the red handle to the left until it stops) and allow the fryer to refill.

9.After all oil is pumped back into the frypot, bubbles will form, indicating air in the oil return lines. Allow the oil to bubble for 10- 15 seconds to ensure all oil is evacuated from the return lines. Turn the yellow handle (left) to close the oil return valve and deactivate the filter pump.

10.If the oil level is low, add oil until the level is at the top OIL LEVEL line. DO NOT

OVERFILL THE FRYPOT.

WARNING

DO NOT OVERFILL THE FYPOT. This will cause oil to splash out of the frypot during cooking and may cause burns or damage.

Turn the yellow handle (right) to open the oil return valve and activate the filter pump.

After filtering is complete, push the red drain handle (left) to close the drain and start refilling the frypot.

Allow the oil to bubble for 10-15 seconds to ensure evacuation of all oil in the return lines and turn the yellow handle to left to deactivate pump.

4-9

Image 24
Contents Hour Service Hotline Frymaster BK1814E Series Electric FryerCanada Page Tilt Housing BK1814E Series Electric Fryer Table of Contents Operator Troubleshooting Safety Information GeneralController Information European Community CE Specific Information DefinitionsShipping Damage Claim Procedure Service InformationGeneral Clearance and Ventilation Australian RequirementsPower Requirements Three 3 Phase RequirementsPage Equipment Setup and Shutdown Procedures Shutdown ControllersPage Filter Preparation Filter Components Assembling the Filter Return filter pan to cabinet Installing the Filter Filtering Tools Operating the Filter 4.5.1 Filter Operation Filter Operation Overfill the FrypotFilter Pump Reset Switch Draining and Disposing of Waste Oil Page Clean the Frypot and Heating Elements- Weekly Annual/Periodic System InspectionFryer Built-In Filtration System Before calling a service agent or the Frymaster Hotline IntroductionProblem Probable Causes Corrective Action Troubleshooting Controller and Heating ProblemsProblem Probable Causes Error Messages and Display ProblemsFiltration Problems StartUser Replaceable Parts Part Number DescriptionFilter Pan Components This page Intentionally Left Blank Service Hotline