Jenn-Air W10342490D Vent System USE, Vent System Care, Operating Downdraft Vent, Filters

Page 14

VENT SYSTEM USE

The retractable downdraft vent system is designed to remove smoke, cooking vapors and odors from the cooktop area.

For best results, the vent should be operating before cooking is started.

If you use large or tall utensils, place them on the large rear element or burner surface.

A higher heat setting than normally used may be needed when the downdraft vent is operating.

For gas cooktops, the downdraft vent system may affect the flame stability and cooking performance. To improve the burner performance, either decrease the downdraft vent blower speed or increase the cooktop burner flame setting.

For gas cooktops with flame sensing ignitions, the downdraft vent system may disperse the flame away from the spark igniter and may cause it to continually spark while trying to reignite a burner that is already lit. To resolve the issue of the cooktop igniter continuously sparking, either decrease the downdraft vent blower speed or increase the cooktop flame setting for that burner.

Operating Downdraft Vent

To Use:

1.Push and hold the button on top of downdraft vent for a few seconds. (This slight delay helps avoid unintentional raising of the vent during cleaning of the cooktop area.) Retractable section of downdraft vent will rise. Blower will begin to vent immediately if blower control knob slider is set to an “On” position.

2.Slide the control slider on the right-hand side of the downdraft vent to adjust the blower motor speed.

When Cooking Is Complete:

1.Push the button on top of the retractable downdraft vent. The blower will turn off, and the retractable section of the vent will return to the closed position.

NOTE: If a spill occurs on the cooktop that allows liquids to seep inside the downdraft vent, you must turn the downdraft vent off immediately. It is possible to cause damage to the downdraft vent if water is allowed inside the downdraft vent while it is operating.

2.Immediately turn off the downdraft vent at the speed control located on the right-hand side of the downdraft vent.

3.Turn off the power supply to the downdraft vent at the circuit breaker box or fuse box.

4.Allow plenty of time for the downdraft vent to dry naturally. Do not open the downdraft vent to remove the water.

VENT SYSTEM CARE

Surface of Downdraft Vent

To avoid damaging the finish, clean downdraft vent with soap and water. Do not use scouring powder or abrasive solutions.

Exterior Surfaces:

To avoid damage to the exterior surface, do not use steel wool or soap-filled scouring pads.

Always wipe dry to avoid water marks.

Cleaning Method:

Liquid detergent soap and water, or all-purpose cleanser

Wipe with damp soft cloth or nonabrasive sponge, then rinse with clean water and wipe dry.

Filters

Frequently remove and clean the filter(s) in the retractable section of the downdraft vent. This will improve the operating efficiency of the downdraft vent system.

To Replace:

1.Remove each filter by pulling the spring release handle and then pulling down the filter.

2.Wash metal filters as needed in dishwasher or hot detergent solution.

3.Reinstall the filter by making sure the spring release handles are toward the front. Insert metal grease filter into upper track.

4.Pull the spring release handle down.

5.Push up on metal filter and release handle to latch into place.

6.Repeat steps 1-5 for the other filter.

To Clean:

1.Remove the filter(s) and clean them in a dishwasher or in a hot detergent solution. The downdraft vent will not operate when the filters are not in place.

2.Dry the clean filter(s) and reinstall, making sure that they lock into place.

If Retractable Downdraft Vent Does Not Operate After Clean Filters Have Been Installed:

Push the filter in as far as it will go. When the filter is removed, the microswitch behind the filter is inactivated. This feature will not allow the vent system to operate until the filter is properly installed.

A

B

C

A.Spring release handles

B.Left metal filter

C.Right metal filter

14

Image 14
Contents Installation Instructions and Use & Care Guide LI3ZVB/W10342490DTable DES Matières Table of ContentsVent System Safety Important Safety Instructions Location Requirements Installation RequirementsTools and Parts Product Dimensions Cabinet Dimension Countertop Cutout DimensionsElectrical Requirements Countertop Cutout Dimensions ChartCold Weather Installations Venting RequirementsInstallation Instructions Venting Methods¹⁄₄ x 10 8.3 cm x 25.4 cm Install Vent SystemExample Vent System Vent Piece RectangularBottom Venting Left or Right VentingRear View Rear Mounting Blower MotorFront View Cm Round Vent Transition With Damper Complete Installation¹⁄₄ x 10 8.3 x 25.4 cm Back Draft Damper Make Electrical Connections Check OperationOperating Downdraft Vent Vent System USEVent System Care Surface of Downdraft VentWiring Diagram OFFIf you need replacement parts Assistance or ServiceAccessories U.S.AJENN-AIRMAJOR Appliance Warranty This limited warranty does not coverPage Sécurité DU Système DE Ventilation Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Outils et pièces Exigences DinstallationExigences d’emplacement Dimensions du produit Ventilateur monté dorigineDimensions du placard Plan de travail-Dimensions des ouvertures à découperExigences concernant lévacuation Installations dans les régions au climat froidSpécifications électriques Air d’appointMéthodes d’évacuation Instructions DinstallationConfiguration avec encastrement Longueur maximum du circuit d’évacuation Installation du conduit d’évacuationCalcul de la longueur effective du circuit d’évacuation Exemple de circuit d’évacuationÉvacuation par le bas Sortie par le côté gauche ou le côté droitVue arrière Montage du ventilateur à larrièreVue de face Raccord de transition rond de 6 15,2 cm avec clapet Achever l’installationClapet anti-retour de 3¹⁄₄ x 10 8,3 x 25,4 cm Raccordements électriques Utilisation du système d’extraction par le Bas Utilisation DU Système D’EXTRACTIONContrôle du fonctionnement UtilisationFiltres Entretien DU Système D’ÉVACUATIONSurface du système d’extraction par le bas Schéma DE Câblage Au Canada Assistance OU ServiceAccessoires Si vous avez besoin de pièces de rechangeGarantie DES Gros Appareils Ménagers JENN-AIR La présente garantie limitée ne couvre pasW10342490D