Jenn-Air W10430955A Electrical Requirements U.S.A. Only, Example vent system

Page 7

Example vent system

wall cap

90˚ elbow

6 ft (1.8 m)

2ft

(0.6 m)

Maximum length

= 60 ft (18.3 m)

1- 90° elbow

= 5 ft (1.5 m)

8 ft (2.4 m) straight

= 8 ft (2.4 m)

1 - wall cap

= 0 ft (0 m)

 

 

System length

= 13 ft (3.9 m)

NOTE: For external venting, flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.

Electrical Requirements - U.S.A. Only

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes.

Do not use an extension cord.

Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/ NFPA 70-latest edition and all local codes and ordinances.

A copy of the above code standards can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169-7471

WARNING: Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service technician if you are in doubt as to whether the appliance is properly grounded. Do not modify the power supply cord plug. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.

Electrical Connection

To properly install your range, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

Range must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located behind the control panel or on the oven frame behind the storage drawer panel. Refer to the figures in the “Product Dimensions” section of the “Location Requirements” section.

This range is manufactured with the neutral terminal connected to the cabinet. Use a 3-wire, UL listed, 40- or

50-amp power supply cord (pigtail) (see following Range Rating chart). If local codes do not permit ground through the neutral, use a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for use with ranges.

Range Rating*

 

Specified Rating of

 

 

Power Supply Cord Kit

 

 

and Circuit Protection

 

 

 

120/240 Volts

120/208 Volts

Amps

 

 

 

8.8 - 16.5 KW

7.8 - 12.5 KW

40 or 50**

16.6 - 22.5 KW

12.6 - 18.5 KW

50

 

 

 

*The NEC calculated load is less than the total connected load listed on the model/serial rating plate.

**If connecting to a 50-amp circuit, use a 50-amp rated cord with kit. For 50-amp rated cord kits, use kits that specify use with a nominal 1³⁄₈" (34.9 mm) diameter connection opening.

A circuit breaker is recommended.

The range can be connected directly to the circuit breaker box (or fused disconnect) through flexible or nonmetallic sheathed, copper or aluminum cable. See “Electrical Connection.”

Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that the range can be moved if servicing is ever necessary.

A UL listed conduit connector must be provided at each end of the power supply cable (at the range and at the junction box).

Wire sizes and connections must conform with the rating of the range.

The wiring diagram is located on the back of the access panel in a plastic bag.

If connecting to a 4-wire system:

This range is manufactured with the ground connected to the neutral by a link. The ground must be revised so the green ground wire of the 4-wire power supply cord is connected to the cabinet. See “Electrical Connection.”

Grounding through the neutral conductor is prohibited for new branch-circuit installations (1996 NEC); mobile homes; and recreational vehicles, or an area where local codes prohibit grounding through the neutral conductor.

When a 4-wire receptacle of NEMA Type 14-50R is used, a matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power supply cord (pigtail) must be used. This cord contains 4 copper conductors with ring terminals or open-end spade terminals with upturned ends, terminating in a NEMA Type 14-50P plug on the supply end.

The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft (1.22 m) long.

4-wire receptacle (14-50R)

The minimum conductor sized for the copper 4-wire power cord are:

40-amp circuit

2 No.-8 conductors

1 No.-10 white neutral

1 No.-8 green grounding

7

Image 7
Contents Table of Contents/Table des matières Your safety and the safety of others are very important Range SafetyTools and Parts Installation RequirementsLocation Requirements Product Dimensions Cabinet Dimensions Floor Venting Venting RequirementsVenting Methods Wall VentingLeft or Right Side Venting Concrete Slab Installations Exhaust Through WallConcrete Slab Installations Exhaust Through Window Well Calculating Vent System LengthElectrical Connection If connecting to a 4-wire systemElectrical Requirements U.S.A. Only Example vent systemElectrical Requirements Canada Only If connecting to a 3-wire systemCountertop Preparation Unpack Range Installation InstructionsAdjust Leveling Legs Install Anti-Tip BracketFloor Mounting Wall Mounting Install Downdraft SystemRear Wall Venting Determine Equivalent Length of Vent SystemTop View Top View View from Motor Side of Blower Style 1 Power supply cord strain relief Power Supply Cord Direct WireElectrical Connection U.S.A. Only Removable retaining nut Strain relief Style 2 Direct wire strain reliefWire connection Power Supply Cord Wire Connection Direct Wire Wire Awg Torque Bare Wire Torque SpecificationsGauge copper Lbs-in .8 N-m Gauge aluminum Lbs-in .0 N-m Connect Range to Downdraft System Wall Venting Top View Side Venting left side venting shown Verify Anti-Tip Is Installed and EngagedFloor Venting Top View Moving the Range Complete InstallationIf you need Assistance or Service For power supply cord-connected rangesFor direct-wired ranges Votre sécurité et celle des autres est très importante Sécurité DE LA CuisinièreExigences d’emplacement Exigences D’INSTALLATIONOutils et pièces Dimensions du produit Dimensions du placardAir d’appoint Installations dans les régions au climat froidExigences concernant l’évacuation Pour obtenir des performances optimalesÉvacuation par le plancher Installations sur dalle de béton Évacuation par le murMéthodes d’évacuation Évacuation par le murLongueur maximum = 60 pi 18,3 m Calcul de la longueur effective du circuit d’évacuationExemple de circuit d’évacuation Composant Conduit de diamètre de 15,2 cm Coude àCuisinières encastrées uniquement Préparation du plan de travailDéballage de la cuisinière Instructions D’INSTALLATIONRéglage des pieds de nivellement Montage au plancher Montage mural Installation de la bride antibasculementInstallation du circuit d’évacuation par le Bas Déterminer la longueur équivalente du circuit d’évacuationVue de dessus Évacuation par le mur arrièreVue de dessus Vue du ventilateur coté moteur Placer 2 cales en bois et les fixer au sol Évacuation par le plancher Vue de dessus Évacuation par le mur Vue de dessusÉvacuation latérale évacuation par la gauche illustrée Achever l’installationSi la cuisinière ne fonctionne pas, contrôler ce qui suit Pour les cuisinières avec câblage direct Déplacement de la cuisinièreSi vous avez besoin d’assistance ou de service Cuisinières alimentées par cordon d’alimentation2011 12/11 All rights reserved W10430955A

W10430955A specifications

The Jenn-Air W10430955A is a premium kitchen appliance designed to elevate culinary experiences and integrate seamlessly into modern kitchens. As a vital component of Jenn-Air's commitment to innovation and performance, the W10430955A represents a fusion of advanced technology and stylish design.

One of the standout features of the W10430955A is its precision cooking technology. This appliance is engineered to provide consistent, even cooking results, thanks to its advanced temperature management system. This system allows home cooks to achieve professional-grade results, whether they are baking, roasting, or broiling.

Moreover, the W10430955A incorporates a sleek, intuitive control panel that simplifies operation. With its user-friendly interface, cooks can easily select settings, adjust temperatures, and monitor cooking times with precision. The touch-sensitive controls not only enhance functionality but also contribute to the overall aesthetic of the appliance, offering a modern touch to any kitchen decor.

In terms of design, the W10430955A features a contemporary look with high-quality materials, including stainless steel finishes that are both durable and easy to clean. The appliance is also designed for energy efficiency, which not only reduces utility bills but also makes it an environmentally friendly choice for those striving to minimize their carbon footprint.

Another commendable characteristic of the W10430955A is its flexibility in cooking options. It often includes multiple cooking modes that cater to various culinary techniques, providing versatility for a wide range of dishes. Whether preparing a delicate soufflé or a hearty casserole, this appliance stands out for its adaptability.

Furthermore, maintenance is hassle-free with this model. Many components are designed for easy removal and cleaning, ensuring that users can keep their appliance in optimal condition with minimal effort.

Overall, the Jenn-Air W10430955A is an exceptional combination of performance, style, and convenience. Its innovative technologies and user-friendly features make it an ideal choice for both amateur cooks and seasoned chefs looking to enhance their culinary skills in a modern kitchen setting. Investing in this appliance not only elevates cooking experiences but also adds a touch of elegance to any home.