Cecilware GB-IT operation manual Program Mode, Functions, Portion control, Teach Me Timer Setup

Page 10

PROGRAM MODE

General Conventions (unless otherwise indicated)

1.To enter or exit Program Mode simultaneously depress both the Rinse key and the Stop key until the buzzer sounds (approximately 1.5 seconds).

2.Pressing the Stop key will cause the menu to scroll up and pressing the Rinse key will cause the menu to scroll down.

3.The blinking LED's) signify which Hopper or Serving Size the displayed parameter corresponds to.

4.Pressing the ▼or ▲ keys individually will decrease or increase the displayed parameter respectively.

5.Pressing the ▼and ▲ simultaneously will cause the parameter to revert to a default value.

Functions:

1.All Dispense LED’s will be illuminated and the LCD/VFD screen will display the following:

2.If the Stop key is pressed the LCD/VFD screen will display the following:

3.Pressing any of the Dispense keys will cause the Dispense LED of the corresponding key to blink and the LCD/VFD screen will display the serving counter for the indicated Dispense key as follows:

4.Pressing any of the Dispense keys will cause the Dispense LED of the corresponding key to blink and the LCD/VFD screen will display the Serving Counter for the indicated Dispense key as follows:

5.If the Stop key is pressed the LCD/VFD screen will display the following:

6.If the▼or ▲ keys are pressed the Dispense Mode will toggle between “free flow” and

“portion control”.

7.If the Stop key is pressed the LCD/VFD screen will display the following:

8. Pressing the ▼and ▲ keys simultaneously will cause the menu to display the following:

DISPENSE TOTAL

SELECT A KEY

DISPENSE TOTAL

#######.# OZ.

SERVING COUNTER

SELECT A KEY

SERVING COUNTER

##### CUPS

DISPENSE

DISPENSE MODE

MODE FREE

PORTION CONTROL

FLOW

 

 

 

TEACH-ME SETUP

ARE YOU SURE ?

TEACH-ME SETUP

SELECT A KEY

Teach Me Timer Setup

A.Place cup or decanter under the desired nozzle.

B.Press one of the illuminated Dispense keys corresponding to the selected nozzle to begin dispensing.

C.Release the Dispense key to stop dispensing.

D.Wait a short time to allow the foam to settle.

E.Jog the Dispense key as needed to top off cup or decanter.

F.If desired simultaneously press the ▼and ▲ keys to use the last Serving Size for all equal cup sizes. Repeat steps A-F for each Dispense key as required.

9.If the Stop key is pressed the LCD/VFD screen will display the following:

10.Pressing any of the Dispense keys will cause the Dispense LED of the corresponding key to blink and the LCD/VFD screen will display the Serving Size for the indicated Dispense key as follows:

11.Pressing ▼or ▲ key will decrease or increase the Serving Size respectively.

12.If the Stop key is pressed the LCD/VFD screen will display the following:

SERVING SIZE SELECT A KEY

SERVING SIZE

##.# OZ.

GRAM THROW SELECT A KEY

10

Image 10
Contents GB-IT Intelligent Technology Installation Instructions Mechanical SpecificationsElectrical Specifications Unpacking InstructionsFor Coffee START-UP ProcedureFor Cappuccino For SoupGB3M-5.5-IT Dimensions & Conponents Location ILL. a Water Level ControlsAdjustments ILL. B Features and Benefits of the Digital Dispenser Controller Parameter Definitions for System Software Version OFF Rinse Mode Initializing ModeNormal Mode Programming Instructions ILL. CFunctions Program ModeTeach Me Timer Setup Portion controlService Mode General ConventionsGram Throw Select a KEY Rinse Lockout Definition of Screens During Normal Operation Definition of Error Screens and Troubleshooting Tests Over Temperature / Over Flow Error ScreenCommunications Error Screen Communications Failure ScreenCheck ALL Dispense Valves for Lime BUILD-UP Recommended Preventive MaintenanceClean OUT Vent MOTOR, Trough and Tubing Check ALL Chamber Mounts for Signs of WearTo replace the Fluorescent Bulb SANITIZING, Cleaning and Refilling Hoppers CleaningHopper and Dispensing Chamber Assys with Wire Augers ILL. E Hopper and Dispensing Chamber Assy with Nylon Augers ILL. E Problem Probable Cause Remedy Set Temperature at 195F See Programming InstructionsTank ASS’Y ILL. F GB3M-10-IT Door ASS’Y with Components GB3M5.5 IT Shown ILL. GDescription Description QTYPage GBM-5.5-IT Common Parts Identification List DescriptionPage Page Page Page Page Page Using Older Version of Touch PAD with ONE Ribbon Connector Using Older Version of Touch PAD with ONE Ribbon Connector