Cecilware GB-IT Programming Instructions ILL. C, Modes of Operation, Initializing Mode

Page 9

25.Default Parameters – This screen gives the user the ability to reset all system parameters except the Grand Total, Dispense Total, and Cups Dispensed. Simultaneously depressing the￿ and ￿ keys will force all system parameters to revert to designated individual default settings.

*Important Note* The default status for all Hoppers is OFF. Thus before any Hopper will dispense the Hopper Status must be manually set to ON.

PROGRAMMING INSTRUCTIONS – ILL. C

To access SERVICE MODE – Press simultaneously

Center of CECILWARE LOGO

and

Center of FAST FLOW LOGO

 

To access PROGRAM MODE – Press simultaneously

 

 

RINSE

 

and

STOP

 

 

 

 

 

 

 

To decrease or increase parameters

LCD WINDOW

PLEASE SELECT DRINK…..

RED – LED BLINKING LIGHTS

GREEN – DISPENSE BUTTON

The a functional description of Version 1.07 of the dispensing controller is as follows:

MODES OF OPERATION

1.Initializing Mode – This mode is only active during the first few seconds after a “power-on” or system reset. The main function of this mode is to configure the system using the previously saved operating parameters.

2.Normal Mode – This mode becomes active immediately after Initializing Mode has completed its tasks. The main functions of this mode are to monitor and report system status and control dispensing.

3.Rinse Mode – This mode becomes active when the Rinse key is depressed while in Normal Mode. The main function of this mode is to allow the operator to initiate an individual Rinse for any enabled Hopper.

4.Program Mode – This mode becomes active when the Rinse and the Stop keys are simultaneously depressed for more than 1.5 seconds while in Normal Mode. The main function of this mode is to provide limited access to frequently used system parameters.

5.Service Mode – This mode becomes active when the hidden keys under the “Cecilware Logo” and the “Fast Flow Logo” are simultaneously depressed for more than 1.5 seconds while in Normal Mode. The main function of this mode is to allow access to all system parameters that can be modified.

INITIALIZING MODE

The following screen signifies this presence of this mode:

It should be noted that this is the only time the System Software Version Number (V #.##) is displayed. All other functions of this mode are completely transparent to the operator.

NORMAL MODE

CECILWARE

DISPENSER V #.##

The following is a list of functions performed by this mode:

1.Dispensing Control – This mode is responsible for implementing and supervising the dispensing process.

2.Water Level Control – This mode is responsible for maintaining the proper level of water in the reservoir tank.

3.Water Temperature Control – This mode is responsible for maintaining the required water temperature in the reservoir tank.

4.Sanitary (Rinse) Functions – This mode is responsible for annunciating and enforcing rinse warnings and lockouts.

5.Safety Functions – This mode is responsible for monitoring all sensors, motors, solenoids, and heaters for proper operation.

RINSE MODE

An individual Rinse is initiated by simultaneously pressing the Rinse key and a Dispense key corresponding to the hopper to be rinsed.

9

Image 9
Contents GB-IT Intelligent Technology Electrical Specifications Mechanical SpecificationsInstallation Instructions Unpacking InstructionsFor Cappuccino START-UP ProcedureFor Coffee For SoupWater Level Controls GB3M-5.5-IT Dimensions & Conponents Location ILL. aAdjustments ILL. B Features and Benefits of the Digital Dispenser Controller Parameter Definitions for System Software Version OFF Normal Mode Initializing ModeRinse Mode Programming Instructions ILL. CTeach Me Timer Setup Program ModeFunctions Portion controlGeneral Conventions Service ModeGram Throw Select a KEY Rinse Lockout Definition of Screens During Normal Operation Definition of Error Screens and Troubleshooting Communications Error Screen Over Temperature / Over Flow Error ScreenTests Communications Failure ScreenClean OUT Vent MOTOR, Trough and Tubing Recommended Preventive MaintenanceCheck ALL Dispense Valves for Lime BUILD-UP Check ALL Chamber Mounts for Signs of WearTo replace the Fluorescent Bulb Cleaning SANITIZING, Cleaning and Refilling HoppersHopper and Dispensing Chamber Assys with Wire Augers ILL. E Hopper and Dispensing Chamber Assy with Nylon Augers ILL. E Set Temperature at 195F See Programming Instructions Problem Probable Cause RemedyTank ASS’Y ILL. F Description Door ASS’Y with Components GB3M5.5 IT Shown ILL. GGB3M-10-IT Description QTYPage Description GBM-5.5-IT Common Parts Identification ListPage Page Page Page Page Page Using Older Version of Touch PAD with ONE Ribbon Connector Using Older Version of Touch PAD with ONE Ribbon Connector