25.Default Parameters – This screen gives the user the ability to reset all system parameters except the Grand Total, Dispense Total, and Cups Dispensed. Simultaneously depressing the and keys will force all system parameters to revert to designated individual default settings.
*Important Note* The default status for all Hoppers is OFF. Thus before any Hopper will dispense the Hopper Status must be manually set to ON.
PROGRAMMING INSTRUCTIONS – ILL. C
To access SERVICE MODE – Press simultaneously
Center of CECILWARE LOGO | and | Center of FAST FLOW LOGO | ||||
| To access PROGRAM MODE – Press simultaneously |
| ||||
| RINSE |
| and | STOP | ||
|
|
|
|
|
|
|
To decrease or increase parameters
LCD WINDOW
PLEASE SELECT DRINK…..
RED – LED BLINKING LIGHTS
GREEN – DISPENSE BUTTON
The a functional description of Version 1.07 of the dispensing controller is as follows:
MODES OF OPERATION
1.Initializing Mode – This mode is only active during the first few seconds after a
2.Normal Mode – This mode becomes active immediately after Initializing Mode has completed its tasks. The main functions of this mode are to monitor and report system status and control dispensing.
3.Rinse Mode – This mode becomes active when the Rinse key is depressed while in Normal Mode. The main function of this mode is to allow the operator to initiate an individual Rinse for any enabled Hopper.
4.Program Mode – This mode becomes active when the Rinse and the Stop keys are simultaneously depressed for more than 1.5 seconds while in Normal Mode. The main function of this mode is to provide limited access to frequently used system parameters.
5.Service Mode – This mode becomes active when the hidden keys under the “Cecilware Logo” and the “Fast Flow Logo” are simultaneously depressed for more than 1.5 seconds while in Normal Mode. The main function of this mode is to allow access to all system parameters that can be modified.
INITIALIZING MODE
The following screen signifies this presence of this mode:
It should be noted that this is the only time the System Software Version Number (V #.##) is displayed. All other functions of this mode are completely transparent to the operator.
NORMAL MODE
CECILWARE
DISPENSER V #.##
The following is a list of functions performed by this mode:
1.Dispensing Control – This mode is responsible for implementing and supervising the dispensing process.
2.Water Level Control – This mode is responsible for maintaining the proper level of water in the reservoir tank.
3.Water Temperature Control – This mode is responsible for maintaining the required water temperature in the reservoir tank.
4.Sanitary (Rinse) Functions – This mode is responsible for annunciating and enforcing rinse warnings and lockouts.
5.Safety Functions – This mode is responsible for monitoring all sensors, motors, solenoids, and heaters for proper operation.
RINSE MODE
An individual Rinse is initiated by simultaneously pressing the Rinse key and a Dispense key corresponding to the hopper to be rinsed.
9