Cecilware GB-IT operation manual Tank ASS’Y ILL. F

Page 23

15. Noise coming

a) Whipper blade not properly aligned or

a) Check blade alignment, if needed replace blade and mixing

 

from mixing

missing.

chamber.

 

chamber

 

 

 

 

 

 

16.

Grinding noise

a) Hopper not properly engaged in back, or

a) Check the mating between the auger motor’s

 

coming from

Hopper not seated properly

gear and hopper’s coupling/nut. Check also pin in base.

 

unit

 

Pin must be dropped into hole in base.

 

 

 

 

17.

Banging or

a) One or more Hoppers are empty or almost

a) Fill Hoppers with product.

 

clicking noise

empty.

 

 

coming from

 

 

 

hoppers

 

 

TANK ASS’Y - ILL. F

1

2

3

1

4

5

6

7

8

9

10

11

12

13

14

15

16

17

ITEM

DESCRIPTION

P/N

QTY

1

SCREW, S.S., 1/4 - 20 x 5/8

P465A

3

2

HEATER, 120V 1700W

G267A

1

 

HEATER, 240V, 3000W

G266A

 

3

GASKET, TANK HEATER

M502A

1

4

RUBBER GASKET, FOR SCREW (ITEM 1 P446A)

M533A

2

5

TUBE

K525A

1

6

TANK TOP

RY98A

1

7

WATER LEVEL PROBE [K402A + P410A]

K402Q

1

8

HI-LIMIT [TEMP.]

L573A

1

9

GROMMET PLUG (.466 ID) F/TESTING TEMP.

M494A

1

10

THERMISTER PROBE [L616A-PROBE, L617A-SILICONE TUBE]

L639Q

1

11

HEATER DUCT HOUSING

RJ82A

1

12

SILICONE BUTT SPLICED GASKET [GB2MD]

M498A

1

 

SILICONE BUTT SPLICED GASKET (GB3MD)

M499A

 

 

SILICONE BUTT SPLICED GASKET [GB4MD]

M500A

 

 

SILICONE BUTT SPLICED GASKET (GB5MD)

M473A

 

 

 

 

 

13

TANK COVER BRACKETS

RI42A

2

14

TANK BODY

RI38A

1

15

GROMMET (.466 ID)

M461A

9*

16

DISPENSE VALVE (DUMP)

L467A

3*

17

TANK INSULATION MATERIAL

M183A

1

18

DRAIN HOSE (on a roll)

M483A

1

19

SILICONE DRAIN PLUG

M391A

1

20

COPPER PLATE- HEAT SINK FOR TRIAC

K770A

1

 

WINGED NUT for mounting plate to tank

P301A

2

21

TRIAC 35 AMP

L623A

1

 

SCREW for Triac

P182A

2

 

 

 

 

* Quantity shown is for GB3M5.5 IT. Quantities very for each unit.

18

19 20 21

23

Image 23
Contents GB-IT Intelligent Technology Unpacking Instructions Mechanical SpecificationsElectrical Specifications Installation InstructionsFor Soup START-UP ProcedureFor Cappuccino For CoffeeWater Level Controls GB3M-5.5-IT Dimensions & Conponents Location ILL. aAdjustments ILL. B Features and Benefits of the Digital Dispenser Controller Parameter Definitions for System Software Version OFF Programming Instructions ILL. C Initializing ModeNormal Mode Rinse ModePortion control Program ModeTeach Me Timer Setup FunctionsGeneral Conventions Service ModeGram Throw Select a KEY Rinse Lockout Definition of Screens During Normal Operation Definition of Error Screens and Troubleshooting Communications Failure Screen Over Temperature / Over Flow Error ScreenCommunications Error Screen TestsCheck ALL Chamber Mounts for Signs of Wear Recommended Preventive MaintenanceClean OUT Vent MOTOR, Trough and Tubing Check ALL Dispense Valves for Lime BUILD-UPTo replace the Fluorescent Bulb Cleaning SANITIZING, Cleaning and Refilling Hoppers Hopper and Dispensing Chamber Assys with Wire Augers ILL. E Hopper and Dispensing Chamber Assy with Nylon Augers ILL. E Set Temperature at 195F See Programming Instructions Problem Probable Cause RemedyTank ASS’Y ILL. F Description QTY Door ASS’Y with Components GB3M5.5 IT Shown ILL. GDescription GB3M-10-ITPage Description GBM-5.5-IT Common Parts Identification ListPage Page Page Page Page Page Using Older Version of Touch PAD with ONE Ribbon Connector Using Older Version of Touch PAD with ONE Ribbon Connector