ADJUSTMENTS - ILL. B
WATER FLOW RATE
The Dispense Valves are factory adjusted fo r a maximum Flow Rate of 1 to 1.3 oz./sec. [Approximate settings: 0.85 to 1 oz./sec for SOUP; 1.3 oz./sec. for COFFEE and CAPPUCCINO] Exceeding this Flow Rate will cause the Mixing Chamber to overflow.
Note: To access the Water Dispense Valves, open door and remove Hoppers.
TO ADJUST WATER FLOW RATE:
1.Open door and remove hoppers. Locate Dispense Valve behind hoppers, mounted on tank.
2.Locate adjustment screw on Dispense Valve.
3. Using Allen Key or flat screwdriver rotate, 1/4 turn at a time, CLOCKWISE to decrease water flow, or
to increase water flow.
4. Check water flow output, after each 1/4 turn.
COUNTERCLOCKWISE
HOPPERS AND AUGERS
CD130 NYLON AUGER [22.5mm%%c X 17mmPT]
CD101 WIRE AUGER [22.5mm%%c X 17mmPT]
CAPPUCCINO/FAST FLOW & SOUP
CD149 WIRE AUGER {22.5mm%%c X 24.8mmPT]
HOT CHOCOLATE & THICK SOUP
CD74A WIRE AUGER {17mm%%c X 12mmPT]
DRY COFFEE/FAST FLOW
CD153 WIRE AUGER [17mm%%c X 9.15mmPT]
DRY COFFEE & INSTANT ESPRESSO
AUGER GEAR
CD117 [w/NYLON AUGER CD130] CD117 [w/WIRE AUGER CD101 & CD149] CD97A [w/WIRE AUGER CD74A & CD153]
AUGERS:OR
PRODUCT
GUIDE
CD70A
CD90A CD76A
CD115
SPLASH GUARD
A.When using NYLON AUGERS: Adjust Water Flow Rate so that the water level reaches almost at the top in the Mixing Chamber, as shown.
B.When using WIRE AUGERS: Adjust Water Flow Rate so that the water level reaches half way up
in the Mixing Chamber, as shown.
DISPENSE CAP | DISPENSE CAP |
CD61A | CD61A |
TRIANGULAR | RECTANGULAR RIB |
RIB |
|
CORRECT WATER
LEVEL FOR MAX
FLOW RATE WHEN
USING WIRE AUGER
|
| CORRECT WATER |
| |
|
| LEVEL FOR MAX |
| |
|
| FLOW RATE WHEN |
| |
MIXING CHAMBER CD145 | MIXING CHAMBER CD137 | USING NYLON | MIXING CHAMBER CD62A | |
AUGER | SOUP UNITS | |||
FAST FLOW [COLD] | FAST FLOW [HOT] | |||
|
|