Variety Steamer
Troubleshooting
WARNING
To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip- ment should be performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are required.
Problem | Possible Cause | Corrective Action | |
Rocker Switch (power | Power Cord not correctly plugged in. | Plug in the power cord correctly. | |
On/Off) is turned on but | The power cord and/or electrical plug | Inspect electrical wire, plug, and receptacle. | |
the Switch Indicator Light | is damaged. |
| |
is still off and the Control |
|
| |
The main electrical panel circuit break- | Reset circuit breaker. Contact your mainte- | ||
Panel is blank | |||
er is off or has been tripped. | nance person or Authorized Service Agency if | ||
| |||
|
| it trips again. | |
| Rocker Switch is inoperable. | Contact your maintenance person or | |
|
| Authorized Service Agency for service. | |
The unit’s main electri- | Damaged receptacle, plug, or cord; a | Turn the unit off, allow it to cool to room tem- | |
cal panel circuit breaker | loose connection or an internal compo- | perature, and then restart the unit. | |
trips. | nent failure. |
| |
Power On/Off switch and | Control Board is inoperable. | Contact your maintenance person or | |
indicator are on but the | Transformer is inoperable. | Authorized Service Agency for service. | |
display is blank. |
|
| |
Loose or burnt wiring in heating circuit. |
| ||
|
| ||
Power On/Off switch is | Heat Relay is inoperable. | Reset the | |
turned on, the switch | the Operations section of this manual. If the | ||
indicator light is on, the |
| ||
Thermocouple is inoperable. | |||
control panel display is | ting, contact your maintenance person or | ||
Control Board is inoperable. | |||
on, but the unit is not | Authorized Service Agency for service. | ||
heating up. | Steam Generator is inoperable. |
| |
| Loose or burnt wiring in heating circuit. |
| |
Unit heats but there is lit- | Water Line Valve is closed. | Check that the Water Line Valve is open. | |
tle or no steam produced | Filter Strainer is restricted. | Check and clean the Filter Strainer as | |
and/or |
| described in the Maintenance section of this | |
| manual. | ||
|
| ||
The product requires | Quick Disconnect is not fully engaged | Remove and reengage the Quick Disconnect | |
more steaming than | at rear of the unit or is damaged. | firmly until a “click” is heard. Replace if dam- | |
usual. |
| aged. | |
| Low or no water pressure in water line. | Remove the Quick Disconnect Insert from the | |
|
| rear of the unit. While holding into an empty | |
|
| cup, press the white plastic tip. Strong steady | |
|
| water flow should be noted. If so, | |
|
| firmly into unit. If not present, or pressure | |
|
| is low, contact your maintenance person or | |
|
| plumber. | |
| Spray Tube is restricted. | Remove and clean Spray Tube as described | |
|
| in the Maintenance section of this manual. | |
| Black Manifold orifices are restricted. | Remove and clean the Black Manifold as | |
|
| described in the Maintenance section of this | |
|
| manual. | |
| Unit is not being cleaned daily or prop- | Clean unit daily as described in the | |
| erly. | Maintenance section of this manual. | |
|
|
| |
P/N 1010745 Rev. G 03/06 | 19 |
|