Antunes, AJ VS-350 owner manual Troubleshooting, Problem Possible Cause Corrective Action

Page 19

Variety Steamer

Troubleshooting

WARNING

To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip- ment should be performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are required.

Problem

Possible Cause

Corrective Action

Rocker Switch (power

Power Cord not correctly plugged in.

Plug in the power cord correctly.

On/Off) is turned on but

The power cord and/or electrical plug

Inspect electrical wire, plug, and receptacle.

the Switch Indicator Light

is damaged.

 

is still off and the Control

 

 

The main electrical panel circuit break-

Reset circuit breaker. Contact your mainte-

Panel is blank

er is off or has been tripped.

nance person or Authorized Service Agency if

 

 

 

it trips again.

 

Rocker Switch is inoperable.

Contact your maintenance person or

 

 

Authorized Service Agency for service.

The unit’s main electri-

Damaged receptacle, plug, or cord; a

Turn the unit off, allow it to cool to room tem-

cal panel circuit breaker

loose connection or an internal compo-

perature, and then restart the unit.

trips.

nent failure.

 

Power On/Off switch and

Control Board is inoperable.

Contact your maintenance person or

indicator are on but the

Transformer is inoperable.

Authorized Service Agency for service.

display is blank.

 

 

Loose or burnt wiring in heating circuit.

 

 

 

Power On/Off switch is

Heat Relay is inoperable.

Reset the Hi-Limit Thermostat according to

turned on, the switch

Hi-Limit Thermostat is tripped.

the Operations section of this manual. If the

indicator light is on, the

 

Hi-Limit Thermostat requries continuous reset-

Thermocouple is inoperable.

control panel display is

ting, contact your maintenance person or

Control Board is inoperable.

on, but the unit is not

Authorized Service Agency for service.

heating up.

Steam Generator is inoperable.

 

 

Loose or burnt wiring in heating circuit.

 

Unit heats but there is lit-

Water Line Valve is closed.

Check that the Water Line Valve is open.

tle or no steam produced

Filter Strainer is restricted.

Check and clean the Filter Strainer as

and/or

 

described in the Maintenance section of this

 

manual.

 

 

The product requires

Quick Disconnect is not fully engaged

Remove and reengage the Quick Disconnect

more steaming than

at rear of the unit or is damaged.

firmly until a “click” is heard. Replace if dam-

usual.

 

aged.

 

Low or no water pressure in water line.

Remove the Quick Disconnect Insert from the

 

 

rear of the unit. While holding into an empty

 

 

cup, press the white plastic tip. Strong steady

 

 

water flow should be noted. If so, re-engage

 

 

firmly into unit. If not present, or pressure

 

 

is low, contact your maintenance person or

 

 

plumber.

 

Spray Tube is restricted.

Remove and clean Spray Tube as described

 

 

in the Maintenance section of this manual.

 

Black Manifold orifices are restricted.

Remove and clean the Black Manifold as

 

 

described in the Maintenance section of this

 

 

manual.

 

Unit is not being cleaned daily or prop-

Clean unit daily as described in the

 

erly.

Maintenance section of this manual.

 

 

 

P/N 1010745 Rev. G 03/06

19

 

Image 19
Contents Variety Steamer Owner Information Table of contentsService/Technical Assistance Important Safety Information Variety Steamer Dimensions SpecificationsElectrical Cord & Plug Configurations Shipping WeightUnpacking InstallationEquipment Setup Water Pressure Regulator Installation InstructionsElectrical DrainSteaming Guide Connecting Single Water Pressure RegulatorOperator Controls OperationOperating Instructions Steaming TipsGeneral Programming Factory SettingsWhen the Program button is pressed ProgrammingShot Steam Shot Time Used for Saving All Changed SettingsCyc Total Cycle Time Rate Shot Interval TimeDaily Cleaning MaintenanceMonthly Cleaning the Steam Generator Pressure Relief Plunger Variety Steamer Components & Accessories Diagnostics Checking and Cleaning the Water Strainer Monthly Part Description Qty ERR Technical Theory of Operation Problem Possible Cause Corrective Action TroubleshootingProblem Prossible Cause Corrective Action Unless Otherwise Specified Wiring DiagramReplacement Parts Petrol Gel not shown Limited Warranty