MIRACLE STEAMER

OPERATION

General (All Units Except MS-150/250 - Mfg. #9100424, 432, 433 & 439)

When the Operate button (Figure 5a) is pressed, power is supplied to the water pump (MS-150/155/355) or the solenoid valve (MS-250/255). The pump/solenoid operates and water sprays onto the heated Steam Generator. The water flashes immediately into live steam and shoots down onto the product.

General (MS-150/250 - Mfg. #9100424, 9100432, 433, & 9100439 Only)

When the Single Shot button (Figure 5b) is pressed, power is supplied to the Solenoid/Water Pump. The solenoid/ water pump operates and water sprays onto the heated Steam Generator. The water flashes imme- diately into live steam and shoots down onto the prod- uct.

One of two operational modes can be used:

Single Shot or Timed Cycle

One of two operational modes can be used: Single Shot or Timed Cycle

SINGLE SHOT

The Operate button is pressed to initiate a single steam shot. The control board applies power to the water pump/solenoid and a “shot” of steam occurs.

TIMED CYCLE

The control is used to set the desired cook time (up to 99 minutes, 59 seconds). When the Start/Stop but- ton is pressed, the Control Board applies power to the water pump/solenoid at regular intervals for the dura- tion of the displayed cycle time. The display counts down to zero and, when the cycle is complete, sounds an audible signal, and then reverts back to the original programmed cycle time. The unit is ready for the next cycle when the green ready light is on.

SINGLE SHOT

The Single Shot button is pressed to initiate a single steam shot. The Control Board applies power to the Solenoid/Water pump and a “shot” of steam occurs.

TIMED CYCLE

The control is used to set the desired cook time (up to 99 minutes, 59 seconds). When the Operate but- ton is pressed, the Control Board applies power to the solenoid at regular intervals for the duration of the displayed cycle time. The display counts down to zero and, when the cycle is complete, sounds an audible signal, and then reverts back to the original programmed cycle time. The unit is ready for the next cycle when the green ready light is on.

READY

 

 

UP

DOWN

PRGM

START/STOP

POWER

 

 

 

Ready Light

Message

Display

Start/Stop

Button

Operate

Button

Rocker Switch (Power On/Off)

 

 

 

Ready Light

READY

 

 

 

 

 

Message

 

 

 

Display

 

 

 

Single Shot

UP

DOWN

PROGRAM SINGLE SHOT

Button

 

 

 

Operate

 

 

 

Button

 

 

 

Rocker Switch

POWER

 

 

(Power On/Off)

 

 

 

Figure 5a. Operating Controls (all units EXCEPT MS-150/250 Mfg. #9100424, 9100432, 9100433, & 9100439)

Figure 5b. Operating Controls (MS-150/250Mfg. #9100424, 9100432, 9100433, &9100439 ONLY)

10

P/N 1010699 Rev. M 12/06

Image 10 Contents
Miracle Steamer Table of Contents Owner InformationImportant Safety Information Service/Technical AssistanceImportant Safety Information DeathElectrical Ratings SpecificationsElectrical Cord & Plug Configurations Model Designation MS-150XX Specifications DimensionsInstallation UnpackingModel MS-150/155 & MS-355 InstallationPlumbing Connecting Water Supply to MS-250/255 Models MS-250/255Single Shot OperationGeneral All Units Except MS-150/250 Mfg. #9100424, 432, 433 Timed CycleOperation ProgrammingSHO Fault Codes Hi-Limit Reset ButtonStatus Indicator LEDs Daily MaintenanceMonthly Maintenance Cleaning Steam GeneratorMiracle Steamer Components Water Tank FILTER-MODELS MS-150/155 only Water Tank Filter-MS-150/155 OnlyTechnical Theory of Operation Troubleshooting Problem Possible Cause Corrective ActionTroubleshooting Miracle Steamer Replacement Parts Replacement Parts MS-150/155 Service CompartmentMS-250/255 Service Compartment MS-150/155/250/255 Item Part No Description QtyItem Part No Description MS-355 Service Compartment MS-355 Item Part No Description Qty Part Description Qty Wiring Diagrams Unless Otherwise SpecifiedLimited Warranty