MIRACLE STEAMER
TROUBLESHOOTING
WARNING
To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip- ment should be performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are required.
Problem | Possible Cause | Corrective Action | |
Control Display is Blank (power On/ | The power cord is not correctly | Plug the power cord into the appro- | |
Off switch is On but indicator light is | plugged in. | priate outlet. | |
off). | The power cord and/or electrical | Inspect electrical wire, plug, and | |
| plug is damaged. | receptacle. | |
| The main electrical panel circuit | Reset circuit breaker. Contact your | |
| breaker is off or has been tripped. | maintenance person or Authorized | |
|
| Service Agency if it trips again. | |
| Switch is inoperable. | Contact your maintenance person or | |
|
| Authorized Service Agency for ser- | |
|
| vice. | |
Control Display is blank (power On/ | Control Board is inoperable | Contact your maintenance person or | |
Off switch is on and indicator light is | Transformer is inoperable. | Authorized Service Agency for ser- | |
on). |
| vice. | |
Loose, burnt, or broken wires in cir- | |||
|
| ||
| cuit. |
| |
Unit does not heat up (Control | Reset the | ||
Display is on) | inoperable. | according to the Operations sec- | |
| Solid State Relay is inoperable. | tion of this manual. If the | |
|
| Thermostat requires continuous | |
| Thermocouple is inoperable. | ||
| resetting, contact your Authorized | ||
| Control Board is inoperable. | ||
| Service Agency for service. | ||
| Steam Generator is inoperable. |
| |
| Loose, burnt, or broken wires in cir- |
| |
| cuit. |
| |
The unit’s main electrical panel cir- | Damaged receptacle, plug, or cord; | Turn the unit off, allow it to cool to | |
cuit breaker trips. | a loose connection or an internal | room temperature, and then restart | |
| component failure. | the unit. Contact your maintenance | |
|
| person or Authorized Service Agency | |
|
| if the condition repeats. | |
Water leaking inside electrical hous- | Pinhole leak in rubber hoses (MS- | Replace hoses. | |
ing. | 150/155/355). |
| |
| Loose or damaged water line tubes | Tighten or replace tubes and/or fit- | |
| and/or fittings inside electrical hous- | tings. | |
| ing. |
| |
“ERR” appears in the Control | Programming and/or SHO and | Reset the Control Board as | |
Display. | H2O values were adjusted/changed | described in the Programing section | |
| improperly. | of this manual. See Fault Codes. |
P/N 1010699 Rev. M 12/06 | 19 |