Antunes, AJ MS-150/155 owner manual Troubleshooting, Problem Possible Cause Corrective Action

Page 19

MIRACLE STEAMER

TROUBLESHOOTING

WARNING

To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip- ment should be performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are required.

Problem

Possible Cause

Corrective Action

Control Display is Blank (power On/

The power cord is not correctly

Plug the power cord into the appro-

Off switch is On but indicator light is

plugged in.

priate outlet.

off).

The power cord and/or electrical

Inspect electrical wire, plug, and

 

plug is damaged.

receptacle.

 

The main electrical panel circuit

Reset circuit breaker. Contact your

 

breaker is off or has been tripped.

maintenance person or Authorized

 

 

Service Agency if it trips again.

 

Switch is inoperable.

Contact your maintenance person or

 

 

Authorized Service Agency for ser-

 

 

vice.

Control Display is blank (power On/

Control Board is inoperable

Contact your maintenance person or

Off switch is on and indicator light is

Transformer is inoperable.

Authorized Service Agency for ser-

on).

 

vice.

Loose, burnt, or broken wires in cir-

 

 

 

cuit.

 

Unit does not heat up (Control

Hi-Limit Thermostat is tripped or

Reset the Hi-Limit Thermostat

Display is on)

inoperable.

according to the Operations sec-

 

Solid State Relay is inoperable.

tion of this manual. If the Hi-Limit

 

 

Thermostat requires continuous

 

Thermocouple is inoperable.

 

resetting, contact your Authorized

 

Control Board is inoperable.

 

Service Agency for service.

 

Steam Generator is inoperable.

 

 

Loose, burnt, or broken wires in cir-

 

 

cuit.

 

The unit’s main electrical panel cir-

Damaged receptacle, plug, or cord;

Turn the unit off, allow it to cool to

cuit breaker trips.

a loose connection or an internal

room temperature, and then restart

 

component failure.

the unit. Contact your maintenance

 

 

person or Authorized Service Agency

 

 

if the condition repeats.

Water leaking inside electrical hous-

Pinhole leak in rubber hoses (MS-

Replace hoses.

ing.

150/155/355).

 

 

Loose or damaged water line tubes

Tighten or replace tubes and/or fit-

 

and/or fittings inside electrical hous-

tings.

 

ing.

 

ERR” appears in the Control

Programming and/or SHO and

Reset the Control Board as

Display.

H2O values were adjusted/changed

described in the Programing section

 

improperly.

of this manual. See Fault Codes.

P/N 1010699 Rev. M 12/06

19

Image 19 Contents
Miracle Steamer Owner Information Table of ContentsService/Technical Assistance Important Safety InformationDeath Important Safety InformationModel Designation MS-150XX SpecificationsElectrical Cord & Plug Configurations Electrical RatingsDimensions SpecificationsUnpacking InstallationModel MS-150/155 & MS-355 InstallationPlumbing Models MS-250/255 Connecting Water Supply to MS-250/255Timed Cycle OperationGeneral All Units Except MS-150/250 Mfg. #9100424, 432, 433 Single ShotProgramming OperationSHO Fault Codes Hi-Limit Reset ButtonStatus Indicator LEDs Daily MaintenanceMonthly Cleaning Steam Generator MaintenanceMiracle Steamer Components Water Tank Filter-MS-150/155 Only Water Tank FILTER-MODELS MS-150/155 onlyTechnical Theory of Operation Problem Possible Cause Corrective Action TroubleshootingTroubleshooting Miracle Steamer Replacement Parts MS-150/155 Service Compartment Replacement PartsMS-250/255 Service Compartment Item Part No Description Qty MS-150/155/250/255Item Part No Description MS-355 Service Compartment MS-355 Item Part No Description Qty Part Description Qty Unless Otherwise Specified Wiring DiagramsLimited Warranty