MIRACLE STEAMER
OPERATION (continued)
Hi-Limit Reset Button
A
| Cap | |
|
|
|
|
|
|
Power Cord
Figure 7. Hi-Limit Reset Button (MS-150 shown)
Fault Codes
When the programming parameters for Minutes/ Seconds/SHO/H2O have been inadvertently changed below or above their limits, the unit displays the “ERR” fault code. If this code appears, clear these settings using the procedure below:
1.Turn the unit off.
2.Press and hold the Program and Start/Stop buttons simultaneously (for all units except MS- 150/250 with Mfg. number 9100424, 432, 433 & 439) or Up and Down Arrow buttons for MS- 150/250 with Mfg. number 9100424, 432, 433, & 439 only).
3.Turn the unit on while holding the appropriate buttons. Release the buttons when the unit stops beeping,
4.The display will now register the cycle time.
NOTE: Repeat these steps if the unit still displays the ERR fault code.
NOTE: It is recommended that the SHO and H2O settings be adjusted to the recommended settings shown in the Programming section of this manual.
Status Indicator LEDs
The Miracle Steamer’s Control Board has 4 Status Indicator LEDs described below:
Green (Program): When lit, indicates the unit is in Program mode.
Yellow (Audio): When lit, indicates
Red (Heat): When lit, indicates the Control Board is calling for heat by supplying
Green (H2O): When lit, indicates that 24 VAC is being supplied to operate the solenoid valve
READY |
| |
| ERR | |
UP | DOWN | PRGM START/STOP |
POWER
The “ERR” Fault Code
P/N 1010699 Rev. M 12/06 | 13 |