Sanyo MDF-U7486SC, MDF-U5486SC instruction manual Precautions for Safe Operation

Page 4

PRECAUTIONS FOR SAFE OPERATION

It is imperative that the user complies with this manual as it contains important safety advice.

Items and procedures are described so that you can use this unit correctly and safely. If the precautions advised are followed, this will prevent possible injury to the user and any other person.

Precautions are illustrated in the following way:

WARNING

Failure to observe WARNING signs could result in a hazard to personnel possibly resulting in serious injury or death.

CAUTION

Failure to observe CAUTION signs could result in injury to personnel and damage to the unit and associated property.

Symbol shows;

this symbol means caution.

￿this symbol means an action is prohibited.

￿this symbol means an instruction must be followed.

Be sure to keep this manual in a place accessible to users of this unit.

Some warning and/or caution labels are attached on the unit. Following shows the description of such labels.

This label is on the cover in which the electrical components of high voltage are enclosed to prevent the electric shock. The cover should be removed by a qualified engineer or a service personnel only.

This symbol means attention or refer to document.

This symbol means earth.

This symbol means power switch “ON”.

This symbol means power switch “OFF”.

WARNING

As with any equipment that uses CO2 gas, there is a likelihood of oxygen depletion in the vicinity of the equipment. It is important that you assess the work site to ensure there is suitable and sufficient ventilation. If restricted ventilation is suspected, then other methods of ensuring a safe environment must be considered. These may include atmosphere monitoring and warning devices.

- 45 -

3

Image 4
Contents MDF-U7486S MDF-U7486SC MDF-U5486S MDF-U5486SC Contents Introduction Precautions for Safe Operation Unqualified personnel may cause electric shock or fire Abnormal operation may cause electric shock or fire Precautions for Safe Operation Environmental Conditions Freezer Components Freezer Components Control panel Installation Site Installation Adjust the leveling footRemove the packaging materials and tapes Fix the unitOperation after power failure START-UP of UnitChamber Temperature Setting KEY Lock FunctionAlarm Temperature Setting Setting of Alarm Resume Time Remote Alarm Terminal AIR Intake PortSetting of Compressor Delay Time Alarms & Safety Functions Alarms and safety functionsCleaning of cabinet Routine MaintenanceCleaning of condenser filter Defrosting of inside wall Cleaning of air intake port Condition Check / RemedyTrouble Shooting Malfunction Check/RemedyDisposal of Unit Recycle of batteryDecontamination of unit Location of a nickel-metal-hydride battery Disposal of BatteryDisposal of nickel-metal-hydride battery BACK-UP System Option Temperature Recorder Option Installation of MTR-85H/MTR-G85Installation of MTR-480/MTR-L03 Interface Board OptionInventory Rack Option MDF-U5486SCSpecifications MDF-U5486SCMDF-U7486SC Performance Safety check sheet

MDF-U5486SC, MDF-U5486S, MDF-U7486S, MDF-U7486SC specifications

Sanyo is a renowned brand in the field of refrigeration and climate control solutions, and its MDF series of laboratory freezers is a testament to its commitment to quality and innovation. The models MDF-U7486SC, MDF-U5486SC, MDF-U7486S, and MDF-U5486S are designed to provide optimal cold storage solutions for sensitive materials in laboratories, clinics, and research facilities.

The MDF-U7486SC and MDF-U5486SC models stand out with their superior temperature stability and precision. Both units feature a microprocessor control system that offers precise temperature regulation, ensuring that stored samples remain within the desired specifications. The cooling system utilizes advanced compressor technology, which enhances energy efficiency while maintaining a low noise operation, making them ideal for quiet laboratory environments.

With a storage capacity of 740 liters for the MDF-U7486SC and 540 liters for the MDF-U5486SC, these freezers provide ample space for large quantities of biological and pharmaceutical materials. The interiors are designed with adjustable shelving, allowing for flexible organization of samples and easy access.

In terms of security, these models come equipped with a comprehensive alarm system that alerts users to deviations in temperature and power failures. The built-in data logger feature records temperature changes, providing a crucial audit trail for compliance and quality assurance.

On the other hand, the MDF-U7486S and MDF-U5486S models offer similar benefits but cater to slightly different needs. The S versions emphasize energy efficiency coupled with a robust cooling performance. They are designed to minimize energy consumption while still delivering reliable cold storage solutions. With an easy-to-use control panel, users can quickly adjust settings and monitor performance, ensuring optimal operation.

All models are constructed with high-quality materials, including a durable exterior that can withstand the rigors of laboratory environments. The insulation is of premium quality, which contributes to maintaining stable internal temperatures while minimizing energy loss.

In conclusion, Sanyo's MDF-U7486SC, MDF-U5486SC, MDF-U7486S, and MDF-U5486S freezers are excellent choices for laboratories looking for reliable, efficient, and secure cold storage solutions. With advanced technologies, robust performance, and user-friendly features, these models meet the diverse needs of scientific research and medical storage while ensuring sample integrity and safety.