Lincoln Series 1000, Series 1200 service manual Parts / 1042

Page 92

 

 

 

 

 

PARTS / 1042, 1043

 

 

 

 

 

 

 

 

 

 

LETTER

 

 

P/N

 

 

DESCRIPTION

 

 

A

369378

 

 

Fan Motor, 230 VAC

 

B

369247

 

 

Shaft Lock Ring

 

C

369248

 

 

Knob

 

D

357107

 

 

Fuse Holder

 

E

369013

 

 

Fuse, 3 Amp

 

 

 

369014

 

 

Fuse, 10 Amp

 

F

369260

 

 

Double Pole Fan Switch

 

G

350224

 

 

Lens, Yellow

 

H

369067

 

 

Air Switch Tube

 

I

369507

 

 

Cooling Fan Thermostat

 

J

369158

 

 

10 Tooth Sprocket, S?n 4390 – Q14970

 

 

 

369066

 

 

Sprocket, ½” – S/n Q14971 & Above - See Page 104

 

L

369025

 

 

Blower Air Switch

 

M

369032

 

 

Relay

 

N

369543

 

 

Transformer, 230/460/575 VAC

 

O

369155

 

 

Conveyor Motor Control Board – S/N 4390 – Q14970

 

 

 

369640

 

 

Control, Stepper, S/n Q14971 & Above

 

P

369240

 

 

Hi-Hat

 

Q

369173

 

 

Control Transformer

 

R

369007

 

 

Temperature Sensing Switch

 

 

 

369902

 

 

Sensing Rod Kit

 

S

369154

 

 

.7 Amp Circuit Breaker

 

T

369393

 

 

Ignition Control NAT/LP

 

U

369331

 

 

Finger Guard, Cooling Fan

 

V

369085

 

 

Junction Box

 

W

353082

 

 

Terminal Lug

 

X

369398

 

 

4” Cover, junction Box-Blank

 

Y

369317

 

 

Pot., Temperature Adjustment w /Faceplate

 

Z

369167

 

 

Set Switch Assy.

 

 

 

369046

 

 

Button only

 

AA

369172

 

 

Digital Display

 

BB

369316

 

 

Knob, Temperature Adjustment

 

CC

369263

 

 

Gas Valve (Body Only), NAT/LP

 

DD

369344

 

 

Pilot Shut Off Valve

 

EE

369086

 

 

Pilot Line Assy., S/N 121 & Above

 

FF

369398

 

 

Solenoid Valve, NAT & LP

 

GG

369072

 

 

Main Burner Orifice, Nat. Gas

 

 

 

369099

 

 

Main Burner Orifice, LP gas

 

HH

369144

 

 

Pilot Shield, Extension

 

JJ

369202

 

 

Pilot Shield, Main

 

KK

369075

 

 

Flame Sensor

 

LL

369073

 

 

Pilot Orifice, Nat. Gas

 

 

 

369100

 

 

Pilot Orifice, LP Gas

 

MM

369076

 

 

Burner Igniter

 

NN

369142

 

 

Flame Target

 

OO

369366

 

 

Burner Blower Motor Kit

 

PP

369531

 

 

Transformer, 120/24V – 40 VA

 

QQ

369270

 

 

Electronic Temperature Control

92

Impinger I -–1000 Series Service Manual - International

Image 92
Contents Impinger Conveyor Ovens Table of Contents Sequence of Operations 1002/1003 Burner CircuitConveyor Drive 100 toSequence of Operations Temperature Sequence of Operations 1028 / 1029 / 1228Heat Circuit ControlTime Temp Sequence of Opertions TIME/TEMPSequence of Operations / 1033, 1034, 1046 TRANSFORMER12.6V Sequence of Operations 1042 / 1043 / 1242 Model 1242 240V 50HZ Natural GAS/DUAL BeltTIME/TEMP Schematic / 1002 Schematic / 1006 to Serial Numbers Q14279 Schematic / 1028, 1029, S/N Q19071 & below Schematic / 1028, 1029, S/N Q19078 & Above Schematic / 1030, to S/N Q17170 Schematic / 1030, S/N Q17171 & Above Schematic / 1032. S/N Q19077 & below Schematic / 1032, S/N Q19078 & Above Schematic / 1033, 1034, 1046 Schematic / 1042, 1043, S/N Q14279 & below Schematic / 1042, 1043, S/N Q14280 & Above Schematic / 1228 , S/N Q14790 & below Schematic / 1228, 1229, S/N Q14791 & Above Schematic / 1242 Troubleshooting Guide 1000 & 1200 / GAS Ovens Symptom Possible Cause EvaluationFor ovens with Johnson ControlsIgnition Control Honeywell IgnitionControl Temperature Control FlameFor ovens withMechanical ThermostatCode Model 1030 Symption Possible Cause EvualationPage Page Page Page Page Page Page Troubleshooting Guide 1000 & 1200 Series / Electric Ovens Page Page Page Page Page Page Troubleshooting / GAS Ovens 1033, 1034, 1046 Page Page Page Page Page Page REMOVAL, Installation & Adjustments MOTOR, Main FANCAPACITOR, Motor FAN, MainCool Down Switch Above GAS Above ElectricRELAY, D.P.S.T Cooling FAN, Control BOXBurner Blower Motor Blower WHEEL, Burner To Remove the Blower Wheel for Periodic CleaningAIR Pressure Switch Burner Assembly Manifold PRESSURE-ADJUSTMENTManifold Pressure Adjustment GAS Control ValveTemperature Control Valve Robert Shaw Temperature Control BoardTemperature Control Potentiometer Replacement Solenoid ValveTHERMOCOUPLE- Replacement Thermocouple Measurement ChartMercury Contactor Heating ElementIgnition Control Flame Sensor 24V GNDBurner Ignitor Transformer 120/24 VACBurner Light 24 VAC GAS Ovens Heat Light 125 VAC Electric OvensConveyor Motor Replacement Bodine SN Conveyor Motor Replacement Baldor 1000 Series SN 4390Main Orifice Burner Potentiometer Conveyor Speed ControlOptical Encoder Assembly Coupling and Encoder DiscTACH. Generator Conveyor Motor Control BoardMotor Control Board Calibration SN 100 to 4389 Bodine SystemMotor Control Board Style 1 Control Board AdjustmentREG MIN MAX Style 2 and Style 3 Control Board Adjustment StyleStyle DIP Switches Control Switch Position OFF Reversing Conveyor Direction Mini Circuit BreakerBEARING, Conveyor Drive ENDHall Effect Sensor Replacement BEARING, Conveyor SN 2164 and AboveTRANSFORMER-STEPPER Motor Control OLD StyleTemperature Gauge Replacement Thermistor ReplacementOven Temperature TRANSFORMER, TIME/TEMP. DisplayType OFF Switch SettingsALL 1000 & 1200 Series Ovens SWITCH, DISPLAY, SET Procedure for USE of TIME/TEMP. SimulatorSwitch Replacement FAN Switch Update Dip SwitchSwitch Replacement FAN, HEAT, Conveyor GAS Valve Replacement and Adjustments Ignition Control Replacement High Limit Thermostat ReplacementSpark Generator Replacement Solenoid Valve ReplacementBurner Alarm Light Replacement Pilot Light 220V ReplacementIgniter Sensor Assembly Replacement Burner Blower Motor ReplacementRelay ASSEMBLY, Burner Blower Motor Replacement Temperature Control ReplacementRELAY, GAS Control Replacement Model 1046,1047 Time Delay RELAY, 20 Minute ReplacementParts / Model Series 1000 & 1200 General Letter DescriptionBlow UP / 1000, 1200 General Parts / Model 1002-1003 , S/N 2584 to Blow UP / 1002, 1003 S/N 2584 to Parts / Model 1002-1003, S/N 4390 & UP SeeBlow UP / 1002, 1003 S/N 4390 & Above Parts / Model SeeBlow UP Parts Blow UP / 1028, 1029 PARTS/ Model Blow UP Parts / 1042 BLOW-UP / 1042 Parts / 1033, 1034, 1046 BLOW-UP / 1033, 1034, 1046 Parts Blow UP / 1228 Parts / 1242 Blow UP / 1242 Parts / Oven Back GAS Blow UP / Oven Back GAS Parts / Oven BACK- Electric Blow UP / Oven Back Electric Parts / Conveyor Motor Assembly S/N 4390 & Above Blow UP / Conveyor Motor Assembly S/N 4390 & Above Parts / Series 1000 Conveyor Blow UP / Series 1000 Conveyor Parts / Series 1200 Conveyor Control Blow UP / Series 1200 Conveyor Control Parts / Series 1200 Conveyor Blow UP / Series 1200 Conveyor 112

Series 1000, Series 1200 specifications

The Lincoln Series 1200 and Series 1000 are two distinguished models in the range of Lincoln Electric welding machines, epitomizing quality, versatility, and advanced technology for both industrial and residential welding applications.

The Lincoln Series 1200 is renowned for its robust build and high-performance capabilities. One of its main features is the ability to perform both MIG (Metal Inert Gas) and stick welding processes, making it a versatile option for various welding requirements. It incorporates an intuitive control panel that allows for easy settings adjustments, ensuring operators can swiftly adapt to different materials and thicknesses. The Series 1200 is equipped with a powerful drive system to provide smooth wire feeding, minimizing downtime due to jams or misfeeds. Additionally, its high-duty cycle support allows continuous operation, making it an ideal choice for professional welders and fabrication shops.

In terms of technology, the Series 1200 employs advanced inverter technology that enhances energy efficiency while reducing the machine’s overall weight. This results in portability without compromising power, making it a practical choice for on-site tasks. Moreover, the machine features an automatic voltage adjustment that optimizes performance based on the input voltage, ensuring reliable operation even under fluctuating power conditions.

On the other hand, the Lincoln Series 1000 is specifically designed for entry-level users and small projects. It shines with its user-friendly interface, which simplifies the welding process for beginners. This model typically includes pre-set parameters and an easy-to-read display, enabling novice operators to achieve excellent welds with minimal experience. Despite its entry-level focus, the Series 1000 does not skimp on performance, offering dependable results across various materials.

Both the Series 1200 and Series 1000 incorporate safety features, including thermal overload protection, ensuring that users can operate the machines with peace of mind. Their durable construction allows for prolonged use in tough work environments without sacrificing reliability.

In conclusion, the Lincoln Series 1200 and Series 1000 cater to a wide range of welding needs, from professional applications to home projects. Their respective features and technologies present options that can fit various skill levels while delivering exceptional welding performance and longevity. Whether you are a seasoned professional or a hobbyist, Lincoln Electric provides reliable solutions to meet your welding requirements.