Lincoln Series 1000, Series 1200 service manual Parts / 1242

Page 98

 

 

 

 

 

PARTS / 1242, 1243

 

 

 

 

 

 

 

 

 

 

LETTER

 

 

P/N

 

 

DESCRIPTION

 

 

A

369247

 

 

Shaft Lock Ring

 

B

357107

 

 

Fuse Holder

 

C

369013

 

 

Fuse, 3 Amp

 

 

 

369014

 

 

Fuse, 10 Amp

 

D

369248

 

 

Knob

 

E

369252

 

 

Paddle Switch

 

F

369260

 

 

Switch, On/Off

 

G

350224

 

 

Lens, Yellow

 

H

369131

 

 

Thermocouple

 

I

369507

 

 

Thermostat, Cooling Fan

 

J

369025

 

 

Air Pressure Switch

 

K

369032

 

 

Relay

 

L

369363

 

 

Cover, Relay

 

M

369543

 

 

Transformer, Power

 

N

369173

 

 

Transformer, 12.6 VAC

 

O

369393

 

 

Ignition Control

 

P

369331

 

 

Finger Guard

 

Q

369366

 

 

Burner Blower Motor

 

R

369317

 

 

Temperature Control Pot.

 

S

369193

 

 

Thermister

 

T

369167

 

 

Set Switch

 

U

369172

 

 

Time/Temp. Display

 

V

369316

 

 

Temperature Dial

 

W

369263

 

 

Gas Valve Nat/LP (Body Only)

 

X

369344

 

 

Pilot Shut-Off Valve

 

Y

369086

 

 

Pilot Line

 

Z

369398

 

 

Solenoid Valve Nat. & LP

 

AA

369072

 

 

Main Burner Orifice, Nat. Gas

 

 

 

369099

 

 

Main Burner Orifice, LP Gas

 

BB

369144

 

 

Pilot Shield, Extension

 

CC

369202

 

 

Pilot Shield, Main

 

DD

369075

 

 

Flame Sensor

 

EE

369073

 

 

Pilot Orifice, Nat. Gas

 

 

 

369100

 

 

Pilot Orifice, LP Gas

 

FF

369076

 

 

Burner Igniter

 

GG

369142

 

 

Flame Target

 

HH

369933

 

 

Flange, Burner

 

II

369007

 

 

Temperature Sensing Switch

 

JJ

369902

 

 

Rod, Sensing Kit

 

KK

369944

 

 

Washer

 

LL

369067

 

 

Air Switch Tube

 

MM

369104

 

 

Pilot Light, 24 VAC

 

NN

369652

 

 

Conveyor Pot. Assy.

 

OO

369378

 

 

Cooling Fan Control Box

 

PP

369531

 

 

Transformer, 120/24, 40 VA

 

QQ

369270

 

 

Temperature Control

98

Impinger I -–1000 Series Service Manual - International

Image 98
Contents Impinger Conveyor Ovens Table of Contents Conveyor Drive Sequence of Operations 1002/1003Burner Circuit 100 toSequence of Operations Heat Circuit TemperatureSequence of Operations 1028 / 1029 / 1228 ControlTime Temp Sequence of Opertions TIME/TEMPSequence of Operations / 1033, 1034, 1046 TRANSFORMER12.6V Sequence of Operations 1042 / 1043 / 1242 Model 1242 240V 50HZ Natural GAS/DUAL BeltTIME/TEMP Schematic / 1002 Schematic / 1006 to Serial Numbers Q14279 Schematic / 1028, 1029, S/N Q19071 & below Schematic / 1028, 1029, S/N Q19078 & Above Schematic / 1030, to S/N Q17170 Schematic / 1030, S/N Q17171 & Above Schematic / 1032. S/N Q19077 & below Schematic / 1032, S/N Q19078 & Above Schematic / 1033, 1034, 1046 Schematic / 1042, 1043, S/N Q14279 & below Schematic / 1042, 1043, S/N Q14280 & Above Schematic / 1228 , S/N Q14790 & below Schematic / 1228, 1229, S/N Q14791 & Above Schematic / 1242 Troubleshooting Guide 1000 & 1200 / GAS Ovens Symptom Possible Cause EvaluationIgnition Control For ovens withJohnson Controls Honeywell IgnitionControl Mechanical Temperature ControlFlameFor ovens with ThermostatCode Model 1030 Symption Possible Cause EvualationPage Page Page Page Page Page Page Troubleshooting Guide 1000 & 1200 Series / Electric Ovens Page Page Page Page Page Page Troubleshooting / GAS Ovens 1033, 1034, 1046 Page Page Page Page Page Page CAPACITOR, Motor REMOVAL, Installation & AdjustmentsMOTOR, Main FAN FAN, MainRELAY, D.P.S.T Cool Down SwitchAbove GAS Above Electric Cooling FAN, Control BOXBurner Blower Motor Blower WHEEL, Burner To Remove the Blower Wheel for Periodic CleaningAIR Pressure Switch Manifold Pressure Adjustment Burner AssemblyManifold PRESSURE-ADJUSTMENT GAS Control ValveTemperature Control Potentiometer Replacement Temperature Control Valve Robert ShawTemperature Control Board Solenoid ValveMercury Contactor THERMOCOUPLE- ReplacementThermocouple Measurement Chart Heating ElementIgnition Control Flame Sensor 24V GNDBurner Light 24 VAC GAS Ovens Burner IgnitorTransformer 120/24 VAC Heat Light 125 VAC Electric OvensMain Orifice Burner Conveyor Motor Replacement Bodine SNConveyor Motor Replacement Baldor 1000 Series SN 4390 Potentiometer Conveyor Speed ControlOptical Encoder Assembly Coupling and Encoder DiscMotor Control Board Calibration TACH. GeneratorConveyor Motor Control Board SN 100 to 4389 Bodine SystemMotor Control Board Style 1 Control Board AdjustmentREG MIN MAX Style 2 and Style 3 Control Board Adjustment StyleStyle DIP Switches Control Switch Position OFF BEARING, Conveyor Reversing Conveyor DirectionMini Circuit Breaker Drive ENDTRANSFORMER-STEPPER Motor Control Hall Effect Sensor ReplacementBEARING, Conveyor SN 2164 and Above OLD StyleOven Temperature Temperature Gauge ReplacementThermistor Replacement TRANSFORMER, TIME/TEMP. DisplayType OFF Switch SettingsALL 1000 & 1200 Series Ovens SWITCH, DISPLAY, SET Procedure for USE of TIME/TEMP. SimulatorSwitch Replacement FAN Switch Update Dip SwitchSwitch Replacement FAN, HEAT, Conveyor GAS Valve Replacement and Adjustments Spark Generator Replacement Ignition Control ReplacementHigh Limit Thermostat Replacement Solenoid Valve ReplacementIgniter Sensor Assembly Replacement Burner Alarm Light ReplacementPilot Light 220V Replacement Burner Blower Motor ReplacementRELAY, GAS Control Replacement Model 1046,1047 Relay ASSEMBLY, Burner Blower Motor ReplacementTemperature Control Replacement Time Delay RELAY, 20 Minute ReplacementParts / Model Series 1000 & 1200 General Letter DescriptionBlow UP / 1000, 1200 General Parts / Model 1002-1003 , S/N 2584 to Blow UP / 1002, 1003 S/N 2584 to Parts / Model 1002-1003, S/N 4390 & UP SeeBlow UP / 1002, 1003 S/N 4390 & Above Parts / Model SeeBlow UP Parts Blow UP / 1028, 1029 PARTS/ Model Blow UP Parts / 1042 BLOW-UP / 1042 Parts / 1033, 1034, 1046 BLOW-UP / 1033, 1034, 1046 Parts Blow UP / 1228 Parts / 1242 Blow UP / 1242 Parts / Oven Back GAS Blow UP / Oven Back GAS Parts / Oven BACK- Electric Blow UP / Oven Back Electric Parts / Conveyor Motor Assembly S/N 4390 & Above Blow UP / Conveyor Motor Assembly S/N 4390 & Above Parts / Series 1000 Conveyor Blow UP / Series 1000 Conveyor Parts / Series 1200 Conveyor Control Blow UP / Series 1200 Conveyor Control Parts / Series 1200 Conveyor Blow UP / Series 1200 Conveyor 112

Series 1000, Series 1200 specifications

The Lincoln Series 1200 and Series 1000 are two distinguished models in the range of Lincoln Electric welding machines, epitomizing quality, versatility, and advanced technology for both industrial and residential welding applications.

The Lincoln Series 1200 is renowned for its robust build and high-performance capabilities. One of its main features is the ability to perform both MIG (Metal Inert Gas) and stick welding processes, making it a versatile option for various welding requirements. It incorporates an intuitive control panel that allows for easy settings adjustments, ensuring operators can swiftly adapt to different materials and thicknesses. The Series 1200 is equipped with a powerful drive system to provide smooth wire feeding, minimizing downtime due to jams or misfeeds. Additionally, its high-duty cycle support allows continuous operation, making it an ideal choice for professional welders and fabrication shops.

In terms of technology, the Series 1200 employs advanced inverter technology that enhances energy efficiency while reducing the machine’s overall weight. This results in portability without compromising power, making it a practical choice for on-site tasks. Moreover, the machine features an automatic voltage adjustment that optimizes performance based on the input voltage, ensuring reliable operation even under fluctuating power conditions.

On the other hand, the Lincoln Series 1000 is specifically designed for entry-level users and small projects. It shines with its user-friendly interface, which simplifies the welding process for beginners. This model typically includes pre-set parameters and an easy-to-read display, enabling novice operators to achieve excellent welds with minimal experience. Despite its entry-level focus, the Series 1000 does not skimp on performance, offering dependable results across various materials.

Both the Series 1200 and Series 1000 incorporate safety features, including thermal overload protection, ensuring that users can operate the machines with peace of mind. Their durable construction allows for prolonged use in tough work environments without sacrificing reliability.

In conclusion, the Lincoln Series 1200 and Series 1000 cater to a wide range of welding needs, from professional applications to home projects. Their respective features and technologies present options that can fit various skill levels while delivering exceptional welding performance and longevity. Whether you are a seasoned professional or a hobbyist, Lincoln Electric provides reliable solutions to meet your welding requirements.