TROUBLESHOOTING GUIDE
GAS OVENS
IMPINGER ADVANTAGE SERIES
SYMPTOM | POSSIBLE CAUSE | EVALUATION |
Oven fan will not run | Incoming Power Supply | Check breakers, reset if required. Call Power Co. if |
NOTE: |
| needed |
| (Export Ovens) | For some export ovens, there is a control circuit step- |
|
| down transformer. This transformer steps down |
|
| supply voltage to 120 VAC. If main fan will not run, |
|
| the secondary of this transformer must be checked |
|
| for 120 VAC output. Check specific oven model |
|
| schematic for circuit location. |
| Oven Fan Fuse | Check and/or Replace |
| Control Fuse | Check and/or Replace |
| Fuse Holder | Check and/or Replace |
| Fan Switch | Check continuity between switch terminals |
| Main Relay | Check continuity to 120 VAC coil. Check for power to |
|
| relay coil (120VAC). Check for supply voltage to |
|
| relay contacts. Visually check for contact |
| Fan Motor | Check for opens, shorts, or ground. WITH POWER |
|
| OFF: Turn Fan Blade to check for locked rotor. |
| Capacitor | Check for opens, shorts, or grounds. |
No control box | Main Fan Relay | Check for power to main fan relay. Visually check for |
cooling |
| contact |
|
| (120 VAC or 240 VAC, check specific model) to |
|
| cooling fan. If voltage is present at the fan motor and |
|
| the fan does not run, replace fan assembly. |
No automatic control | Incoming Power Supply | Check breakers/Reset if needed. Check for incoming |
box cooling |
| power at cooling fan thermostat. |
| Cooling Fan Thermostat | Check cooling fan thermostat (thermostat closes at |
|
| 120°F and opens at 100°F). With cooling fan |
|
| thermostat |
|
| is open, replace. |
| Axial Cooling Fan | WITH POWER OFF: check for locked rotor. Check |
|
| for proper voltage to the cooling fan, if present and |
|
| fan does not run, replace the fan. |
Control box cooling | Cooling Fan Thermostat | See "Cooling Fan Thermostat" (NOTE: Thermostat |
fan continues to run |
| will remain closed if control box temperature |
|
| exceeds 120°F) |
Oven will not heat | Gas Supply | Check for adequate gas supply to oven |
Model |
|
|
| Manual Gas | Check to see that manual |
| Main Oven Fan | Check if main oven fan is operating. If not, refer to |
|
| "Oven fan will not run" on page 11. |
For 1456, 1457, | Centrifugal Switch | Check for 120 VAC on both sides of (Main Fan) |
1475, 1476 See |
| switch. If voltage present on one side only, and motor |
Page 14. |
| is running, replace motor. |
| Transformer, 24 VAC | Check for 120 VAC to primary of transformer. Check |
|
| for 24 VAC from secondary of transformer. If there is |
|
| primary voltage, but no secondary voltage, replace |
|
| transformer. |
| Burner Blower Motor | Check for 120 VAC supply to burner blower motor. If |
|
| 120 VAC is present and motor does not run, replace |
|
| motor. WITH POWER OFF: turn blower wheel to |
|
| check for locked rotor. |
Impinger I – 1400 Series Advantage Service Manual – Dom & Int’l | 11 |