Lincoln 1400 Series Troubleshooting Guide, GAS Ovens, Symptom Possible Cause Evaluation

Page 11

TROUBLESHOOTING GUIDE

GAS OVENS

IMPINGER ADVANTAGE SERIES

SYMPTOM

POSSIBLE CAUSE

EVALUATION

Oven fan will not run

Incoming Power Supply

Check breakers, reset if required. Call Power Co. if

NOTE:

 

needed

 

(Export Ovens)

For some export ovens, there is a control circuit step-

 

 

down transformer. This transformer steps down

 

 

supply voltage to 120 VAC. If main fan will not run,

 

 

the secondary of this transformer must be checked

 

 

for 120 VAC output. Check specific oven model

 

 

schematic for circuit location.

 

Oven Fan Fuse

Check and/or Replace

 

Control Fuse

Check and/or Replace

 

Fuse Holder

Check and/or Replace

 

Fan Switch

Check continuity between switch terminals

 

Main Relay

Check continuity to 120 VAC coil. Check for power to

 

 

relay coil (120VAC). Check for supply voltage to

 

 

relay contacts. Visually check for contact pull-in.

 

Fan Motor

Check for opens, shorts, or ground. WITH POWER

 

 

OFF: Turn Fan Blade to check for locked rotor.

 

Capacitor

Check for opens, shorts, or grounds.

No control box

Main Fan Relay

Check for power to main fan relay. Visually check for

cooling

 

contact pull-in. Axial Cooling Fan. Check for power

 

 

(120 VAC or 240 VAC, check specific model) to

 

 

cooling fan. If voltage is present at the fan motor and

 

 

the fan does not run, replace fan assembly.

No automatic control

Incoming Power Supply

Check breakers/Reset if needed. Check for incoming

box cooling

 

power at cooling fan thermostat.

 

Cooling Fan Thermostat

Check cooling fan thermostat (thermostat closes at

 

 

120°F and opens at 100°F). With cooling fan

 

 

thermostat pre-heated, check for continuity. If switch

 

 

is open, replace.

 

Axial Cooling Fan

WITH POWER OFF: check for locked rotor. Check

 

 

for proper voltage to the cooling fan, if present and

 

 

fan does not run, replace the fan.

Control box cooling

Cooling Fan Thermostat

See "Cooling Fan Thermostat" (NOTE: Thermostat

fan continues to run

 

will remain closed if control box temperature

 

 

exceeds 120°F)

Oven will not heat

Gas Supply

Check for adequate gas supply to oven

Model 1450-1451

 

 

 

Manual Gas Shut-off Valve

Check to see that manual shut-off valve is open

 

Main Oven Fan

Check if main oven fan is operating. If not, refer to

 

 

"Oven fan will not run" on page 11.

For 1456, 1457,

Centrifugal Switch

Check for 120 VAC on both sides of (Main Fan)

1475, 1476 See

 

switch. If voltage present on one side only, and motor

Page 14.

 

is running, replace motor.

 

Transformer, 24 VAC

Check for 120 VAC to primary of transformer. Check

 

 

for 24 VAC from secondary of transformer. If there is

 

 

primary voltage, but no secondary voltage, replace

 

 

transformer.

 

Burner Blower Motor

Check for 120 VAC supply to burner blower motor. If

 

 

120 VAC is present and motor does not run, replace

 

 

motor. WITH POWER OFF: turn blower wheel to

 

 

check for locked rotor.

Impinger I – 1400 Series Advantage Service Manual – Dom & Int’l

11

Image 11
Contents Impinger Conveyor Ovens Table of Contents Sequence of Operations PhaseSequence of Operation Heat Circuit Temperature Control Conveyor Drive Sequence of Operations Schematic 1450 / 1451 Schematic 1452 Schematic 1454 Schematic 1456 Schematic 1474 / 1475 GAS Ovens Troubleshooting GuideSymptom Possible Cause Evaluation Page Code AS FollowsModels 1456 1474-1475-1476 Page Page Page Electric Ovens Impinger Advantage Series Symptom Possible Cause EvaluationPage Page FAN, Main Removal Installation & AdjustmentsMOTOR, Main FAN THERMOSTAT, Cooling FAN CAPACITOR, MotorRELAY, D.P.S.T Cooling FAN, Control BOXBlower WHEEL, Burner Burner Blower Motor ReplacementBurner Control Honeywell Replacement Burner AssemblySolenoid Valve Manifold Pressure AdjustmentElectronic Temperature Control Replacement Burner Ignitor Thermocouple ReplacementThermocouple Measurement Chart Conveyor Drive Motor Replacement Burner Control Transformer -REPLACEMENTConveyor Control Potentiometer 10K OHM Replacement Conveyor Control Board Assembly ReplacementON-OFF Switch Replacement Hall Effect Sensor ReplacementCircuit Breaker Replacement Main Orifice ReplacementGAS Valve Replacement and Adjustments Solenoid Valve Replacement Ignition Control ReplacementHigh Limit Thermostat Replacement Spark Generator ReplacementLetter Description General 1450 SeriesGeneral 1450 Series BLOW-UP Control BOX 1450, 1451 Control BOX 1450, 1451, 1480 BLOW-UP Control BOX 1452 Control BOX 1452, 1453 BLOW-UP Contol BOX 1454 Control BOX 1454, 1455 BLOW-UP Control BOX 1456, 1457, 1474, 1475 Control BOX 1456, 1457, 1474, 1475, 1476 BLOW-UP Oven BACK, GAS Electric Oven BACK, GAS Electric BLOW-UP Conveyor 1450 Series Conveyor 1450 Series BLOW-UP