Lincoln 1400 Series Burner Ignitor, Thermocouple Replacement, Thermocouple Measurement Chart

Page 25

BURNER IGNITOR

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Remove burner assembly. (SEE "BURNER ASSY.")

4.Remove pilot shield and pilot shield extension.

5.Remove burner igniter.

6.Reassemble in reverse order (spark gap approx. .100 in. 2.5 mm) NOTE: Be sure to reconnect burner igniter cable to ignition control.

THERMOCOUPLE - REPLACEMENT

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Slide thermocouple out of oven chamber.

NOTE: Remove conveyor and bottom fingers to aid in removal and installation of thermocouple.

4.Remove two (2) wires from temperature control. Make note of wire numbers or color and location for reinstallation.

5.Reassemble in reverse order making sure the metal end on the thermocouple is securely held in the wire form in the oven chamber.

THERMOCOUPLE MEASUREMENT CHART:

When two wires composed of dissimilar metals are joined together and one of the ends is heated, a continuous current flow is generated. We use an iron constant (Type J) thermocouple. The iron wire increases the number of dissimilar junctions in the circuit.

It is possible to check a thermocouple with a properly calibrated D.C. millivolt meter. At 32°F, the millivolt reading should be 0.00. Inserting the thermocouple into an ice bath can check this.

The millivolt reading at 72°F should be 1.134.

When using the following chart, the temperature at the terminal connections must be noted. This temperature is called the Junction Temperature.

The following chart lists the thermocouple millivolt readings from 200°F to 600°F.

The junction temperature is the ambient air temperature where the thermocouple fastens to the electronic temperature control.

 

 

 

 

O

V

E

N

 

T

E

M

P

 

 

 

 

 

200°F

250°F

300°F

325°F

350°F

400°F

425°F

450°F

500°F

550°F

600°F

 

 

J

90°F

3.26

4.77

6.30

7.06

7.83

9.37

10.14

10.91

12.46

14.00

15.53

 

 

U

88°F

3.32

4.83

6.36

7.12

7.89

9.43

10.20

10.97

12.51

14.05

15.59

 

 

N

86°F

3.37

4.88

6.41

7.17

7.94

9.49

10.26

11.03

12.57

14.11

15.65

 

 

C

84°F

3.43

4.94

6.47

7.23

8.00

9.54

10.31

11.09

12.63

14.19

15.71

 

 

T

82°F

3.49

5.00

6.53

7.29

8.06

9.60

10.37

11.14

12.69

14.23

15.76

 

 

I

80°F

3.55

5.06

6.59

7.35

8.12

9.66

10.43

11.20

12.74

14.28

15.82

 

 

O

78°F

3.60

5.11

6.64

7.40

8.17

9.72

10.49

11.26

12.80

14.34

15.86

 

 

N

76°F

3.66

5.17

6.70

7.46

8.23

9.77

10.55

11.32

12.86

14.40

15.94

 

 

 

75°F

3.69

5.20

6.73

7.49

5.26

9.80

10.57

11.35

12.89

14.43

15.97

 

 

 

74°F

3.72

5.23

6.76

7.52

8.29

9.83

10.60

11.37

12.92

14.46

15.99

 

 

 

72°F

3.78

5.29

6.82

7.58

8.35

9.89

10.66

11.43

12.97

14.51

16.05

 

 

T

70°F

3.83

5.34

6.87

7.63

8.40

9.95

10.72

11.49

13.03

14.57

16.11

 

 

E

68°F

3.89

5.40

6.93

7.69

8.46

10.00

10.78

11.55

13.09

14.63

16.17

 

 

M

66°F

3.95

5.46

6.99

7.75

8.52

10.06

10.83

11.61

13.15

14.69

16.23

 

 

P

64°F

4.01

5.52

7.05

7.81

8.58

10.12

10.89

11.66

13.20

14.74

16.28

 

 

 

62°F

4.06

5.57

7.10

7.86

8.63

10.18

10.95

11.72

13.26

14.80

16.34

 

 

 

60°F

4.12

5.63

7.16

7.92

8.69

10.24

11.01

11.78

13.32

14.86

16.40

 

Impinger I – 1400 Series Advantage Service Manual – Dom & Int’l

 

 

 

25

Image 25
Contents Impinger Conveyor Ovens Table of Contents Sequence of Operation PhaseSequence of Operations Heat Circuit Temperature Control Conveyor Drive Sequence of Operations Schematic 1450 / 1451 Schematic 1452 Schematic 1454 Schematic 1456 Schematic 1474 / 1475 Symptom Possible Cause Evaluation Troubleshooting GuideGAS Ovens Page Code AS FollowsModels 1456 1474-1475-1476 Page Page Page Electric Ovens Impinger Advantage Series Symptom Possible Cause EvaluationPage Page MOTOR, Main FAN Removal Installation & AdjustmentsFAN, Main RELAY, D.P.S.T CAPACITOR, MotorCooling FAN, Control BOX THERMOSTAT, Cooling FANBurner Control Honeywell Replacement Burner Blower Motor ReplacementBurner Assembly Blower WHEEL, BurnerElectronic Temperature Control Replacement Manifold Pressure AdjustmentSolenoid Valve Thermocouple Measurement Chart Thermocouple ReplacementBurner Ignitor Conveyor Control Potentiometer 10K OHM Replacement Burner Control Transformer -REPLACEMENTConveyor Control Board Assembly Replacement Conveyor Drive Motor ReplacementCircuit Breaker Replacement Hall Effect Sensor ReplacementMain Orifice Replacement ON-OFF Switch ReplacementGAS Valve Replacement and Adjustments High Limit Thermostat Replacement Ignition Control ReplacementSpark Generator Replacement Solenoid Valve ReplacementLetter Description General 1450 SeriesGeneral 1450 Series BLOW-UP Control BOX 1450, 1451 Control BOX 1450, 1451, 1480 BLOW-UP Control BOX 1452 Control BOX 1452, 1453 BLOW-UP Contol BOX 1454 Control BOX 1454, 1455 BLOW-UP Control BOX 1456, 1457, 1474, 1475 Control BOX 1456, 1457, 1474, 1475, 1476 BLOW-UP Oven BACK, GAS Electric Oven BACK, GAS Electric BLOW-UP Conveyor 1450 Series Conveyor 1450 Series BLOW-UP