Lincoln 1400 Series service manual GAS Valve Replacement and Adjustments

Page 28

THE FOLLOWING ITEMS ARE USED IN THE MODEL 1456, 1457, 1474, 1475, 1476 IMPINGER OVENS

AIR PRESSURE SWITCHES - REPLACEMENT AND ADJUSTMENT

1.Remove control panel top.

2.Disconnect wires from switch making note of wire number and location for reinstallation.

3.Remove air tube from switch assembly.

4.Remove switch from wire hanger.

5.Install new switch in reverse order, make sure air tube is not blocked or miss-aligned. Adjust as needed. To adjust the air pressure switch, remove snap on cover on the side of the switch to

expose adjusting screw. To increase sensitivity, turn screw counter clockwise; to decrease sensitivity, turn screw clockwise. Check for proper line voltage switching from N.C. to N.O. as the air pressure switch closes.

GAS VALVE - REPLACEMENT AND ADJUSTMENTS

1.Remove control panel top and front cover.

2.Disconnect the gas piping from the back of the unit.

3.Remove the four(4) screws from the incoming nipple mounting bracket.

4.Remove incoming nipple.

5.Disconnect two (2) plugs, (1) 3 prong and (1) 4 prong - Note location.

6.Disconnect pipe union just above gas valve and remove assembly.

7.Reassemble in reverse order (check all pipe fittings for leaks). After assembled, check

for proper adjustment of gas pressure switch, 8.8 on dial for natural gas, 23 for L.P. Gas and

4.5for town gas.

8.Check and adjust manifold pressure. remove pressure tap located in gas piping above the

gas valve prior to the burner orifice and install manometer. Adjustment screw is located on the

front of the valve, remove plastic cap and adjust as needed: 3.5" WC for Natural Gas and 10" WC for L.P.

9.Check gas filter by removing cover plate (located on either side of valve). Remove four (4) screws and slide filter out of valve housing and inspect. Reassemble in reverse order and check

10.for leaks around the cover.

SIDE VIEW

FILTER

COVER

PLATE

PRESSURE CONTROLLER ADJUSTMENT

FILTER

COVER

PLATE

 

TOP VIEW

 

 

 

 

 

OUTPUT

 

 

 

MANIFOLD

 

 

 

PRESSURE

 

 

 

ADJUSTMENT

 

+

gnd

ELECTRICAL

 

 

-

1

2

CONNECTOR

 

 

 

3

 

 

3

 

 

2

 

 

ELECTRICAL

 

 

 

 

gnd

 

CONNECTOR

28

Impinger I – 1400 Series Advantage Service Manual - Dom & Int’l

Image 28
Contents Impinger Conveyor Ovens Table of Contents Sequence of Operation PhaseSequence of Operations Heat Circuit Temperature Control Conveyor Drive Sequence of Operations Schematic 1450 / 1451 Schematic 1452 Schematic 1454 Schematic 1456 Schematic 1474 / 1475 Symptom Possible Cause Evaluation Troubleshooting GuideGAS Ovens Page AS Follows CodeModels 1456 1474-1475-1476 Page Page Page Impinger Advantage Series Symptom Possible Cause Evaluation Electric OvensPage Page MOTOR, Main FAN Removal Installation & AdjustmentsFAN, Main CAPACITOR, Motor RELAY, D.P.S.TCooling FAN, Control BOX THERMOSTAT, Cooling FANBurner Blower Motor Replacement Burner Control Honeywell ReplacementBurner Assembly Blower WHEEL, BurnerElectronic Temperature Control Replacement Manifold Pressure AdjustmentSolenoid Valve Thermocouple Measurement Chart Thermocouple ReplacementBurner Ignitor Burner Control Transformer -REPLACEMENT Conveyor Control Potentiometer 10K OHM ReplacementConveyor Control Board Assembly Replacement Conveyor Drive Motor ReplacementHall Effect Sensor Replacement Circuit Breaker ReplacementMain Orifice Replacement ON-OFF Switch ReplacementGAS Valve Replacement and Adjustments Ignition Control Replacement High Limit Thermostat ReplacementSpark Generator Replacement Solenoid Valve ReplacementGeneral 1450 Series Letter DescriptionGeneral 1450 Series BLOW-UP Control BOX 1450, 1451 Control BOX 1450, 1451, 1480 BLOW-UP Control BOX 1452 Control BOX 1452, 1453 BLOW-UP Contol BOX 1454 Control BOX 1454, 1455 BLOW-UP Control BOX 1456, 1457, 1474, 1475 Control BOX 1456, 1457, 1474, 1475, 1476 BLOW-UP Oven BACK, GAS Electric Oven BACK, GAS Electric BLOW-UP Conveyor 1450 Series Conveyor 1450 Series BLOW-UP