Lincoln 1400 Series Electric Ovens, Impinger Advantage Series Symptom Possible Cause Evaluation

Page 18

TROUBLESHOOTING GUIDE

ELECTRIC OVENS

IMPINGER ADVANTAGE SERIES

SYMPTOM

POSSIBLE CAUSE

EVALUATION

Oven fan will not run

Incoming Power Supply

Check breakers/Reset if required. Call Power Co. if

 

 

needed.

 

Oven Fan Fuse

Check and/or Replace

 

Fuse Holder

Check and/or Replace

 

Fan Switch

Check continuity between switch terminals.

 

 

For these oven models, there is a control circuit step-

 

1454-1455

down transformer. This transformer steps down

 

 

supply voltage to 120 VAC. If main fan will not run, the

 

 

secondary of this transformer must be checked for

 

 

120 VAC output. Check specific oven model

 

 

schematic for circuit location.

 

Main Relay

Check continuity to 120 VAC coil. Check for power to

 

 

the relay coil,(120 VAC). Check for 120/208/220/240

 

 

VAC to relay terminals. Visually check for contact pull-

 

 

in.

 

Fan Motor

Check for opens, shorts, or ground. WITH POWER

 

 

OFF: Turn Fan Blade to check for locked rotor.

 

Capacitor

Check for opens, shorts, or grounds.

No control box

Main Fan Relay

Check for power to main fan relay. Visually check for

cooling

 

contact pull-in.

 

Axial Cooling Fan

WITH POWER OFF: turn fan blade to check for

 

 

locked rotor. Check for power to cooling fan. If voltage

 

 

is present at the fan motor and the fan does not run,

 

 

replace fan assembly.

No automatic control

Incoming Power Supply

Check circuit breakers, reset if required, call Power

box cooling

 

Company if needed.

 

Cooling Fan Thermostat

Thermostat is normally open and closes at 120°F ± 3

 

 

(48.9°C ± 7°), and opens at 100°F ± 3°F (37.8°C ±

 

 

1.7°C).

Oven will not heat

Main Oven Fan

Check if main oven fan is operating. If not, refer to

 

 

"Oven fan will not run". Page 18.

 

Centrifugal Switch (Main Fan)

Check for 120 VAC on both sides of switch. If voltage

 

Model 1452-1453

is present on one side only and motor is running,

 

 

replace motor.

 

Air Pressure Switch

This normally open switch should close when the

 

(1454-1455)

main fan is activated. If adjustment is necessary

 

 

(Refer to page 28). Check tube for blockage. Replace

 

 

if defective.

 

Hi Limit Thermostat (Oven

Terminals are normally closed. If open, reset and test

 

Cavity)

oven for proper operation. If thermostat will not hold

 

 

for maximum oven temperature, and oven is not

 

 

exceeding temperature dial setting, replace

 

 

thermostat.

 

Control Box High Limit

Terminals are normally closed, but open at 130°F ±

 

Thermostat

5°F (53.9°C ± 2.8°C). Check for over heating and

 

 

reset thermostat. Test for proper operation. If it will not

 

 

reset and hold, then replace.

18

Impinger I – 1400 Series Advantage Service Manual - Dom & Int’l

Image 18
Contents Impinger Conveyor Ovens Table of Contents Phase Sequence of OperationSequence of Operations Heat Circuit Temperature Control Conveyor Drive Sequence of Operations Schematic 1450 / 1451 Schematic 1452 Schematic 1454 Schematic 1456 Schematic 1474 / 1475 Troubleshooting Guide Symptom Possible Cause EvaluationGAS Ovens Page AS Follows CodeModels 1456 1474-1475-1476 Page Page Page Impinger Advantage Series Symptom Possible Cause Evaluation Electric OvensPage Page Removal Installation & Adjustments MOTOR, Main FANFAN, Main Cooling FAN, Control BOX CAPACITOR, MotorRELAY, D.P.S.T THERMOSTAT, Cooling FANBurner Assembly Burner Blower Motor ReplacementBurner Control Honeywell Replacement Blower WHEEL, BurnerManifold Pressure Adjustment Electronic Temperature Control ReplacementSolenoid Valve Thermocouple Replacement Thermocouple Measurement ChartBurner Ignitor Conveyor Control Board Assembly Replacement Burner Control Transformer -REPLACEMENTConveyor Control Potentiometer 10K OHM Replacement Conveyor Drive Motor ReplacementMain Orifice Replacement Hall Effect Sensor ReplacementCircuit Breaker Replacement ON-OFF Switch ReplacementGAS Valve Replacement and Adjustments Spark Generator Replacement Ignition Control ReplacementHigh Limit Thermostat Replacement Solenoid Valve ReplacementGeneral 1450 Series Letter DescriptionGeneral 1450 Series BLOW-UP Control BOX 1450, 1451 Control BOX 1450, 1451, 1480 BLOW-UP Control BOX 1452 Control BOX 1452, 1453 BLOW-UP Contol BOX 1454 Control BOX 1454, 1455 BLOW-UP Control BOX 1456, 1457, 1474, 1475 Control BOX 1456, 1457, 1474, 1475, 1476 BLOW-UP Oven BACK, GAS Electric Oven BACK, GAS Electric BLOW-UP Conveyor 1450 Series Conveyor 1450 Series BLOW-UP