TROUBLESHOOTING GUIDE
ELECTRIC OVENS
IMPINGER ADVANTAGE SERIES
SYMPTOM | POSSIBLE CAUSE | EVALUATION |
Oven fan will not run | Incoming Power Supply | Check breakers/Reset if required. Call Power Co. if |
|
| needed. |
| Oven Fan Fuse | Check and/or Replace |
| Fuse Holder | Check and/or Replace |
| Fan Switch | Check continuity between switch terminals. |
|
| For these oven models, there is a control circuit step- |
| down transformer. This transformer steps down | |
|
| supply voltage to 120 VAC. If main fan will not run, the |
|
| secondary of this transformer must be checked for |
|
| 120 VAC output. Check specific oven model |
|
| schematic for circuit location. |
| Main Relay | Check continuity to 120 VAC coil. Check for power to |
|
| the relay coil,(120 VAC). Check for 120/208/220/240 |
|
| VAC to relay terminals. Visually check for contact pull- |
|
| in. |
| Fan Motor | Check for opens, shorts, or ground. WITH POWER |
|
| OFF: Turn Fan Blade to check for locked rotor. |
| Capacitor | Check for opens, shorts, or grounds. |
No control box | Main Fan Relay | Check for power to main fan relay. Visually check for |
cooling |
| contact |
| Axial Cooling Fan | WITH POWER OFF: turn fan blade to check for |
|
| locked rotor. Check for power to cooling fan. If voltage |
|
| is present at the fan motor and the fan does not run, |
|
| replace fan assembly. |
No automatic control | Incoming Power Supply | Check circuit breakers, reset if required, call Power |
box cooling |
| Company if needed. |
| Cooling Fan Thermostat | Thermostat is normally open and closes at 120°F ± 3 |
|
| (48.9°C ± 7°), and opens at 100°F ± 3°F (37.8°C ± |
|
| 1.7°C). |
Oven will not heat | Main Oven Fan | Check if main oven fan is operating. If not, refer to |
|
| "Oven fan will not run". Page 18. |
| Centrifugal Switch (Main Fan) | Check for 120 VAC on both sides of switch. If voltage |
| Model | is present on one side only and motor is running, |
|
| replace motor. |
| Air Pressure Switch | This normally open switch should close when the |
| main fan is activated. If adjustment is necessary | |
|
| (Refer to page 28). Check tube for blockage. Replace |
|
| if defective. |
| Hi Limit Thermostat (Oven | Terminals are normally closed. If open, reset and test |
| Cavity) | oven for proper operation. If thermostat will not hold |
|
| for maximum oven temperature, and oven is not |
|
| exceeding temperature dial setting, replace |
|
| thermostat. |
| Control Box High Limit | Terminals are normally closed, but open at 130°F ± |
| Thermostat | 5°F (53.9°C ± 2.8°C). Check for over heating and |
|
| reset thermostat. Test for proper operation. If it will not |
|
| reset and hold, then replace. |
18 | Impinger I – 1400 Series Advantage Service Manual - Dom & Int’l |