Gas Pressure Switch

This switch is located inside the gas valve and should

 

 

close when gas pressure is present. WITH POWER

 

 

OFF: remove 3 prong plug (on gas valve) and

 

 

measure continuity between terminals 2 and 3.NOTE:

 

 

Remove insulation pad below plug to read numbers. If

 

 

no continuity, check the following:

 

 

1. Proper gas pressure supply to the gas valve as

 

 

marked on the oven specification plate.

 

 

2. Check for proper adjustment of gas pressure

 

 

switch. 8.8 on dial for natural gas, 23 for LP, and 4.5

 

 

for Town Gas.

 

 

3. Check gas filter in gas valve for blockage or

 

 

damage. (See Adjustment Section on page 28). If

 

 

above checks are okay, but pressure switch is still not

 

 

closed, replace gas valve.

 

Hi-Limit Thermostat

Thermostat is normally closed, opens at 368°C

 

 

(695°F). If open, reset and test oven for proper

 

 

operation. If thermostat will not hold for maximum

 

 

oven temperature, and oven is not exceeding

 

 

temperature dial setting, check for proper location of

 

 

capillary bulb in its spring holder. If above checks

 

 

okay, replace hi-limit thermostat.

 

Ignition Control

Check for proper line voltage supply to ignition control,

 

 

terminal #1.Check for proper line voltage to the Burner

 

 

Blower Motor. If voltage is present, proceed with next

 

 

step, if not, wait 30 seconds, push reset button, and

 

 

try to restart. If this fails, check wires from thermostat

 

 

and burner blower motor to the ignition control. If all

 

 

above fails and wires are okay, replace ignition

 

 

control.

 

Burner Blower Motor

Check for line voltage to motor. WITH POWER OFF:

 

 

turn blower wheel to check for locked rotor or blower

 

 

wheel slippage. If proper line voltage is present at

 

 

motor connecting plug, terminal 2 and 5, and motor

 

 

does not run, replace motor.

 

Air Pressure Switch (Burner

Check for proper line voltage switching from "N.C." to

 

Blower)

"N.O." as air pressure switch closes. Check for air

 

 

switch adjustment, air tube blockage, or misalignment,

 

 

and if these fail, replace air pressure switch.

 

Spark Generator

A pre-purge time of 30 to 60 seconds occurs after

 

 

blower motor starts, check for proper line voltage at

 

 

spark generator. If voltage is not present, check reset

 

 

button for the Ignition Control. If voltage is still not

 

 

present, replace ignition control. If voltage is present,

 

 

visually check for spark at igniter head located in end

 

 

of burner.

 

Igniter/Sensor Assembly

Check this assembly for visible damage. If there is no

 

 

damage, replace the spark generator. If there is

 

 

damage, replace the Igniter/Sensor Assembly. Also

 

 

check for frayed or damaged wires in the burner tube.

 

 

Check spark gap (should be .100 inch 2.5 mm).

 

 

Replace as needed.

 

Gas valve

This solenoid is located inside the gas valve and

 

 

should open when proper line voltage is present. If no

 

 

voltage is present, check the reset button on the

 

 

ignition control, and all connections for tightness. If

 

 

there is still no voltage present at gas valve, replace

 

 

ignition control. If there is voltage present, check for

 

 

gas pressure at the gas pressure tap located in the

 

 

gas piping just prior to the burner. If there is no gas

 

 

pressure, replace gas valve.

Impinger I – 1400 Series Advantage Service Manual – Dom & Int’l

15

Image 15
Contents Impinger Conveyor Ovens Table of Contents Phase Sequence of OperationSequence of Operations Heat Circuit Temperature Control Conveyor Drive Sequence of Operations Schematic 1450 / 1451 Schematic 1452 Schematic 1454 Schematic 1456 Schematic 1474 / 1475 Troubleshooting Guide Symptom Possible Cause EvaluationGAS Ovens Page Code AS FollowsModels 1456 1474-1475-1476 Page Page Page Electric Ovens Impinger Advantage Series Symptom Possible Cause EvaluationPage Page Removal Installation & Adjustments MOTOR, Main FANFAN, Main THERMOSTAT, Cooling FAN CAPACITOR, MotorRELAY, D.P.S.T Cooling FAN, Control BOXBlower WHEEL, Burner Burner Blower Motor ReplacementBurner Control Honeywell Replacement Burner AssemblyManifold Pressure Adjustment Electronic Temperature Control ReplacementSolenoid Valve Thermocouple Replacement Thermocouple Measurement ChartBurner Ignitor Conveyor Drive Motor Replacement Burner Control Transformer -REPLACEMENTConveyor Control Potentiometer 10K OHM Replacement Conveyor Control Board Assembly ReplacementON-OFF Switch Replacement Hall Effect Sensor ReplacementCircuit Breaker Replacement Main Orifice ReplacementGAS Valve Replacement and Adjustments Solenoid Valve Replacement Ignition Control ReplacementHigh Limit Thermostat Replacement Spark Generator ReplacementLetter Description General 1450 SeriesGeneral 1450 Series BLOW-UP Control BOX 1450, 1451 Control BOX 1450, 1451, 1480 BLOW-UP Control BOX 1452 Control BOX 1452, 1453 BLOW-UP Contol BOX 1454 Control BOX 1454, 1455 BLOW-UP Control BOX 1456, 1457, 1474, 1475 Control BOX 1456, 1457, 1474, 1475, 1476 BLOW-UP Oven BACK, GAS Electric Oven BACK, GAS Electric BLOW-UP Conveyor 1450 Series Conveyor 1450 Series BLOW-UP