Lincoln 1400 Series service manual Burner Control Transformer -REPLACEMENT, Heat Light

Page 26

BURNER CONTROL TRANSFORMER -REPLACEMENT

1.Shut power off at main breaker.

2.Remove control panel top and front cover.

3.Remove two (2) wires on primary side, note color and location.

4.Remove two (2) wires on secondary side, note color and location.

5.Remove two (2) screws from transformer base and replace assembly.

6.Reinstall in reverse order and check system operation.

HEAT LIGHT

1.Shut off power at main breaker.

2.Remove control panel top and front panel.

3.Remove the two wires from burner light, note number and location.

4.Grasp body of light assembly and slide sideways to remove.

5.Reassemble in reverse order and check.

CONVEYOR CONTROL POTENTIOMETER (10K OHM) - REPLACEMENT

1.Shut power off at main breaker.

2.Remove control panel top and front cover.

3.Remove the access cover.

4.Loosen two (2) allen screws and remove knob by sliding off shaft.

5.Remove mounting nut from potentiometer shaft and push out.

6.Unplug wire connector from conveyor control board.

7.Reassemble in reverse order and check system operation. Recalibrate knob as needed.

CONVEYOR CONTROL BOARD ASSEMBLY - REPLACEMENT

1.Shut power off at main breaker.

2.Remove control panel top and front cover.

3.Remove two (2) top screws and loosen one (1) bottom screw from control assembly.

4.Disconnect wiring (Push on connectors) from control board, note proper location of connectors for reinstallation and exchange boards on the mounting bracket before reinstallation.

5.Reassemble in reverse order and check system operation.

NOTE: Control boards are calibrated at the factory and no board adjustment is required.

CONVEYOR DRIVE MOTOR - REPLACEMENT

1.Shut power off at main breaker.

2.Remove control panel top and front cover.

3.Loosen set screw on conveyor drive sprocket and slide sprocket off shaft.

4.Disconnect motor plug and wiring for hall effect sensor board.

5.Remove four (4) screws from motor frame, on control box side, and remove motor assembly.

6.Remove sensor board. * See Note

7.Reassemble in reverse order making sure to align chain sprockets and adjust motor for proper chain tension ( 1/2" SAG).

NOTE: When replacing the drive motor it will be necessary to also install a new magnet on the shaft up against the shoulder and cement in place.

REVERSING CONVEYOR DIRECTION

All ovens leaving our plant are wired to operate conveyors from left to right. To reverse conveyor direction, use the following procedure.

1.Shut off power at main breaker.

2.Remove control panel top.

3.Remove cover from relay box.

4.Reverse wires fastened to terminals A+ and A- on conveyor control board

5.Reassemble in reverse order.

26

Impinger I – 1400 Series Advantage Service Manual - Dom & Int’l

Image 26
Contents Impinger Conveyor Ovens Table of Contents Sequence of Operations PhaseSequence of Operation Heat Circuit Temperature Control Conveyor Drive Sequence of Operations Schematic 1450 / 1451 Schematic 1452 Schematic 1454 Schematic 1456 Schematic 1474 / 1475 GAS Ovens Troubleshooting GuideSymptom Possible Cause Evaluation Page AS Follows CodeModels 1456 1474-1475-1476 Page Page Page Impinger Advantage Series Symptom Possible Cause Evaluation Electric OvensPage Page FAN, Main Removal Installation & AdjustmentsMOTOR, Main FAN Cooling FAN, Control BOX CAPACITOR, MotorRELAY, D.P.S.T THERMOSTAT, Cooling FANBurner Assembly Burner Blower Motor ReplacementBurner Control Honeywell Replacement Blower WHEEL, BurnerSolenoid Valve Manifold Pressure AdjustmentElectronic Temperature Control Replacement Burner Ignitor Thermocouple ReplacementThermocouple Measurement Chart Conveyor Control Board Assembly Replacement Burner Control Transformer -REPLACEMENTConveyor Control Potentiometer 10K OHM Replacement Conveyor Drive Motor ReplacementMain Orifice Replacement Hall Effect Sensor ReplacementCircuit Breaker Replacement ON-OFF Switch ReplacementGAS Valve Replacement and Adjustments Spark Generator Replacement Ignition Control ReplacementHigh Limit Thermostat Replacement Solenoid Valve ReplacementGeneral 1450 Series Letter DescriptionGeneral 1450 Series BLOW-UP Control BOX 1450, 1451 Control BOX 1450, 1451, 1480 BLOW-UP Control BOX 1452 Control BOX 1452, 1453 BLOW-UP Contol BOX 1454 Control BOX 1454, 1455 BLOW-UP Control BOX 1456, 1457, 1474, 1475 Control BOX 1456, 1457, 1474, 1475, 1476 BLOW-UP Oven BACK, GAS Electric Oven BACK, GAS Electric BLOW-UP Conveyor 1450 Series Conveyor 1450 Series BLOW-UP