Lincoln 1400 Series CAPACITOR, Motor, Relay, D.P.S.T, Cooling FAN, Control BOX, Mercury Contactor

Page 22

CAPACITOR, MOTOR

1.Shut off power at main breaker.

2.Remove motor cover from back of oven. 3.Discharge capacitor.

4.Remove and replace.

RELAY, D.P.S.T.

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Remove cover from relay box.

4.Disconnect all wires and mark for replacement.

5.Remove relay by removing two (2) mounting screws.

6.Reassemble in reverse order.

COOLING FAN, CONTROL BOX

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Remove four (4) screws from the fan frame.

4.Disconnect cord and plug and remove fan.

5.Reassemble in reverse order.

THERMOSTAT, COOLING FAN

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Remove lead wires and mark for reassembly.

4.Remove two (2) screws and remove thermostat.

5.Reassemble in reverse order.

MERCURY CONTACTOR

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Disconnect contactor wires and mark for reinstallation.

4.Remove screws from mounting bracket and replace contactor.

NOTE: Be sure contactor is not mounted upside down as this will cause a constant on condition. 5.Reassemble in reverse order.

HEATING ELEMENTS

1.Shut off power at main breaker.

2.Remove back cover.

3.Disconnect heater element wire and mark for reassembly.

4.Disconnect motor wiring and mark for reassembly.

5.Remove oven back from oven.

6.Remove fan shroud.

7.Heater element may now be unbolted and removed.

8.Check heater elements to be sure they are the proper voltage replacement.

9.Reassemble in reverse order.

NOTE: Be sure the heating element connections are tight.

22

Impinger I – 1400 Series Advantage Service Manual - Dom & Int’l

Image 22
Contents Impinger Conveyor Ovens Table of Contents Sequence of Operation PhaseSequence of Operations Heat Circuit Temperature Control Conveyor Drive Sequence of Operations Schematic 1450 / 1451 Schematic 1452 Schematic 1454 Schematic 1456 Schematic 1474 / 1475 Symptom Possible Cause Evaluation Troubleshooting GuideGAS Ovens Page AS Follows CodeModels 1456 1474-1475-1476 Page Page Page Impinger Advantage Series Symptom Possible Cause Evaluation Electric OvensPage Page MOTOR, Main FAN Removal Installation & AdjustmentsFAN, Main Cooling FAN, Control BOX CAPACITOR, MotorRELAY, D.P.S.T THERMOSTAT, Cooling FANBurner Assembly Burner Blower Motor ReplacementBurner Control Honeywell Replacement Blower WHEEL, BurnerElectronic Temperature Control Replacement Manifold Pressure AdjustmentSolenoid Valve Thermocouple Measurement Chart Thermocouple ReplacementBurner Ignitor Conveyor Control Board Assembly Replacement Burner Control Transformer -REPLACEMENTConveyor Control Potentiometer 10K OHM Replacement Conveyor Drive Motor ReplacementMain Orifice Replacement Hall Effect Sensor ReplacementCircuit Breaker Replacement ON-OFF Switch ReplacementGAS Valve Replacement and Adjustments Spark Generator Replacement Ignition Control ReplacementHigh Limit Thermostat Replacement Solenoid Valve ReplacementGeneral 1450 Series Letter DescriptionGeneral 1450 Series BLOW-UP Control BOX 1450, 1451 Control BOX 1450, 1451, 1480 BLOW-UP Control BOX 1452 Control BOX 1452, 1453 BLOW-UP Contol BOX 1454 Control BOX 1454, 1455 BLOW-UP Control BOX 1456, 1457, 1474, 1475 Control BOX 1456, 1457, 1474, 1475, 1476 BLOW-UP Oven BACK, GAS Electric Oven BACK, GAS Electric BLOW-UP Conveyor 1450 Series Conveyor 1450 Series BLOW-UP